[PDF] Top 20 Film-Forming Amines for the Corrosion Protection of Carbon Steels in Nuclear Power Plant Secondary Circuit Conditions: An Impedance Study
Has 10000 "Film-Forming Amines for the Corrosion Protection of Carbon Steels in Nuclear Power Plant Secondary Circuit Conditions: An Impedance Study" found on our website. Below are the top 20 most common "Film-Forming Amines for the Corrosion Protection of Carbon Steels in Nuclear Power Plant Secondary Circuit Conditions: An Impedance Study".
Film-Forming Amines for the Corrosion Protection of Carbon Steels in Nuclear Power Plant Secondary Circuit Conditions: An Impedance Study
... measurements. The impedance measurements were per formed with a conventional three electrode cell with a mercury sulfate electrode (MSE) in a saturated potassium sulfate solution and a platinum grid, ... Voir le document complet
11
Film-Forming Amines for the Corrosion Protection of Carbon Steels in Nuclear Power Plant Secondary Circuit Conditions: An Impedance Study
... that the thick electrodeposited magnetite layer does not strongly in fluence the electrochemical behavior of the ...to the porous structure of the magnetite, as ... Voir le document complet
12
Impedance analysis of film-forming amines for the corrosion protection of a carbon steel
... periods of pressurized water reactors (PWR) for maintenance operation, strict and restrictive conservation conditions must be respected in order to preserve the secondary ... Voir le document complet
10
Impedance analysis of film-forming amines for the corrosion protection of a carbon steel
... periods of pressurized water reactors (PWR) for maintenance operation, strict and restrictive conservation conditions must be respected in order to preserve the secondary ... Voir le document complet
11
Film-forming amines for corrosion protection of carbon steels in PWR secondary circuit conditions
... shows the impedance diagrams of the carbon steel treated samples with and without ODA at 220 °C during 168 ...h. In this case, the impedance magnitude difference ... Voir le document complet
13
An Impedance Investigation of the Mechanism of Pure Magnesium Corrosion in Sodium Sulfate Solutions
... progressively. The formation of MgO corresponds to the following equilibrium MgO + H 2 O Mg共OH兲 2 关6兴 The thick and porous layer of Mg 共OH兲 2 is formed following ...covers the ... Voir le document complet
7
Study of colloidal particles behaviour in the PWR primary circuit conditions
... Afin, de minimiser cette dosimétrie, EDF cherche à comprendre, modéliser et mieux contrôler le transport des espèces radioactives, et plus généralement des produits de corrosion, dans le circuit primaire. ... Voir le document complet
220
Surface impedance boundary condition with circuit coupling for the 3D finite element modeling of wireless power transfer
... (right) of Z sys at 5 cm range VI. C ONCLUSIONS In this paper, a 3D FE formulation with SIBC and circuit coupling suitable for WPT coils modeling has been ...enables the possibility to ... Voir le document complet
4
An Impedance Investigation of the Mechanism of Pure Magnesium Corrosion in Sodium Sulfate Solutions
... measurements.— The polarization curves were plotted under potentiostatic regulation using a Solartron 1286 Elec- trochemical ...steps of 20 mV every 2 min to ensure quasi-steady-state conditions. ... Voir le document complet
8
Incorporation of an indole-3 butyric acid modified clay in epoxy resin for corrosion protection of carbon steel
... As in the previous study [11] , MMT was treated with IBA (IBA- modi fied clay) by cation ...exchange. The IBA-modified clay was first characterized by infrared spectroscopy and thermogravimetric ... Voir le document complet
8
The influence of galvanic coupling on corrosion of carbon steel coupled with stainless steels
... On the other hand, Knudsen et ...using carbon steel with stainless steel did not increase the risk of corrosion to carbon steel as long as both steels were in a ... Voir le document complet
17
Phenix Nuclear Power Plant Dismantling Start
... Objective of make-safe operation is to reduce risk at the minimum before dismantling (mechanical, electrical, fluid, asbestos, chemical, pressure, ...all the fluids and rinsed all the pipes to ... Voir le document complet
4
The influence of galvanic coupling on corrosion of carbon steel coupled with stainless steels for use in concrete structures
... On the other hand, Knudsen et ...using carbon steel with stainless steel did not increase the risk of corrosion to carbon steel as long as both steels were in a ... Voir le document complet
17
Carbon nanotube-based nanorelays for low-power circuit applications
... In order to control static power dissipation without decreasing the CMOS performance, this thesis proposes a new device that eliminates leakage currents: the carbon [r] ... Voir le document complet
86
Corrosion protection of carbon steel by an epoxy resin containing organically modified clay
... to the preparation and characterization of the properties of organic modified clays but only few papers have presented results concerning the corrosion protection ... Voir le document complet
10
Corrosion protection of carbon steel by an epoxy resin containing organically modified clay
... In the present study, montmorillonite clay was modified by aminotrimethylphosphonic acid (ATMP) and incorporated into an epoxy ...both an alkyl ammonium cation and three phosphonic ... Voir le document complet
9
Layered double hydroxides as containers of inhibitors in organic coatings for corrosion protection of carbon steel
... is an open access repository that collects the work of Toulouse researchers and makes it freely available over the web where ...is an author-deposited version published in : ... Voir le document complet
8
Estimation of steel corrosion rate in reinforced concrete by means of equivalent circuit fittings of impedance spectra
... Advances in Cement Research, 10, (2), April, pp. 43-56, April 01, 1998 The material in this document is covered by the provisions of the Copyright Act, by Canadian laws, ... Voir le document complet
17
Processing and properties of SiC/SiC composites for nuclear power plant applications.
... archive for the deposit and dissemination of sci- entific research documents, whether they are pub- lished or ...not. The documents may come from teaching and research institutions in ... Voir le document complet
23
Layered double hydroxides as containers of inhibitors in organic coatings for corrosion protection of carbon steel
... is an open access repository that collects the work of Toulouse researchers and makes it freely available over the web where ...is an author-deposited version published in : ... Voir le document complet
7
Sujets connexes