Directeur de la Rubrique : J.-S. DELMO'n'E (LILLE).

Collaborateurs : M. BEER GABEL, J. CASSlGNEUL, J.-F. REY.

E d i t o r i a l

La v i d 6 o e n d o s c o p i e 6 1 e 9 le f u t u r , m a i s d ~ j ~ le p r e s e n t !...

J.-S. D E L M O T T E Lille (France)

The electronic video endoscope of tomorrow, but first, its present status

Les ann~es 70 ont vu appara~tre les endoscopes fibres de verre et leur utilisation dans l'exploration de l'appareil digestif a c o n n u le succ~s extraordinaire que l'on sait.

La maison Welch Allyn a cr66 les premiers vid6o, endoscopes et les a pr6sent6 ~ la Soci6t6 am6ricaine de Gastro-ent6rologie il y a 4 ans.

Depuis de n o m b r e u x appareils fonctionnent de par le monde. En 1986, 25 appareils de ce type sont ven- d u s en France p r o b a b l e m e n t une centaine en 1987.

P R I N C I P E D E F O N C T I O N N E M E N T D ' U N VIDJEO-ENDOSCOPE I~,LECTRONIQUE

<< V.E. ~ l~tude du C.C.D.

Le f o n c t i o n n e m e n t d ' u n video-endoscope 61ectroni- que est c o m p a r a b l e ~ celui d ' u n e cam6ra << Solid- S t a t e , ou <~ Chip C a m e r a , . Il est lit ~t l'utilisation d ' u n C . C . D . o u ~ Couple-Charge-Device , .

Ce materiel fut invent6 en 1969 par W.-S. Boyle et G.-E. Smith, se b a s a n t sur les propri6t6s du silicone, corps semi-conducteur sensible ~ la lumi~re.

En effet, un p h o t o n qui f r a p p e une surface de sili- cone d6termine la lib6ration d ' u n $1ectron et la cr6a- tion d ' u n t r o u o p t i q u e charg6 positivement, le tout l'origine d ' u n e f o r m e de c o u r a n t 61ectrique.

Les techniques actuelles de miniaturisation permet- tent la fabrication de cibles a la surface pr6-r6duite.

L ' e n s e m b l e de ces cibles en silicone p e r m e t t r a l'analyse des images. Les cibles sont s6par6es entre elles par des lignes de circuit p e r m e t t a n t le transfert des charges :

- - l'ensemble des cibles et lignes de circuit r6alisent

u n micro-processeur appel6 C . C . D . (Couple-Charge- Device) ;

- - l a cible elle-mSme ou p h o t o - d i o d e est appel6e

Pixels (ou picture element). L e u r n o m b r e d6termine la qualit6 de l'image : plus il y a de Pixels, plus les signaux 61ectriques transmis seront riches et com- plexes, refl6tant ainsi plus fid~lement la r6alit6.

Mais plus un C . C . D . est riche en Pixels, plus il sera volumineux, plus il sera difficile ~ miniaturiser.

E n endoscopie u n 6quilibre devra donc ~tre trouv6 entre la richesse en Pixels et le v o l u m e du C . C . D . Le viddo endoscope dlectronique (V.E.E.) :

Les volumes r6duits de C . C . D . (2,8 m m de diam6- tre p o u r le C . C . D . ) utilis6 p a r Welch Allyn permettent de le placer ~ l'extr~mit6 distale de l'endoscope juste derriere un objectif d o n t le r61e est de concentrer sur la surface sensible, la lumi~re qui sera analys6e.

Le C . C . D . est ~t l'origine de signaux de vid6o- fr6quence qui sont recueillis et transmis par un banal c o r d o n 61ectronique au d6codeur d ' u n moniteur de T.V.

U n V . E . E . c o m p o r t e d o n c :

- - un endoscope avec une pattie m6canique tradi-

tionnelle p o r t e u r d ' u n C . C . D . ; Tir6s ~ part : D r J.-S. DELMOTTE, 104, rue de Jemmapes, 59000 Lille (France).

R U B R I Q U E # D I T I ~ E A V E C LE C O N C O U R S D E S L A B O R A T O I R E S F O U R N I E R - D I J O N

Cet article des Editions Lavoisier est disponible en acces libre et gratuit sur archives-acen.revuesonline.com

(2)

- - u n vid6o-processeur c o m p o r t a n t 6galement un syst~me d ' i n s u f f l a t i o n et d'6clairage ;

- - un m o n i t e u r T.V. d o n t la d6finition condition- hera la qualit6 de l'image.

Les avantages apparaissent ~vidents :

- - la d6finition est sup6rieure ~ celle des fibres opti- ques et th6oriquement cette d6finition peut ~tre aug- ment6e ind6finiment ;

- - t o u t e s les possibilit6s de l'61ectronique 9 stoc-

kage, transmission de signaux peuvent &re utilis6es.

Leur int6rSt est capital p o u r l'6tude, l'enseignement, la diffusion de l ' e n d o s c o p i e ;

- - le C . C . D . poss6de en outre un spectre tr~s large de 300 n m ~ 1 000 nm, sup6rieur aux possibilit6s de l'analyse par l'oeil h u m a i n d'o/~ la possibilit6 th6ori- que de traitement voire de cr6ation d ' i m a g e p a r ordi- nateur.

Creation d ' u n e rubrique sp~cialisde :

La relative complexit6 de l'6tude de ce mat6riel, les possibilit6s diagnostiques immenses qu'il a p p o r t e sont

apparu suffisantes h la r6daction d ' A c t a E n d o s c o p i c a p o u r n6cessiter la cr6ation d ' u n e rubrique sp6ciale pluri-annuelle d o n t elle a bien voulu m ' a t t r i b u e r la responsabilit6.

Cette rubrique c o m p o r t e r a :

- - u n e p r e m i e r e p a r t i e c o n s a c r 6 e h la vid6o- endoscopie 61ectronique (principes th6oriques, appli- cation pratique, recherche et d6veloppement...) ;

- - u n e seconde partie qui recensera, analysera et

critiquera les diff6rentes r6alisations frangaises et 6trang~res en films vid6o.

Les crit~res de s61ection, retenus sont les suivants :

- - sujet : e n d o s c o p i e digestive et application ;

- - dur6e de 10 ~t 30 minutes ;

- - qualit6 technique correcte, n o t a m m e n t possibi-

lit6 de projection en U M A T I C 3 / 4 de pouce ;

- - langue frangaise o u ~trang6re.

L ' e n d o s c o p e utilis6 peut &re indiff6remment : - - soit un f i b r o s c o p e et syst~me de cam6ra 61ectro- nique ;

- - soit un vid6o-endoscope.

REFERENCES LAMBERT R. -- Endoscopie, fibre optique et vid6o : Gastro-

Ent6rologie, Clinique Biologique, 1985, 9, 228-234.

REY J.-F. - - Place de la Vid~o-Endoscopie l~lectronique en

Endoscopie digestive : Acta Endoscopica 1986 CREGG/SMIER Image et Communication.

SIVAK M.-V. -- Video Endoscopy : t~ Clinics in gastro- enterology ~ 1986 tol 15 n ~ 2 205-235.

The 1970"s saw the d e v e l o p m e n t o f the fiberendos- cope a n d its use as a diagnostic tool to e x a m i n e the gastrointestinal tract has been widely a d o p t e d world-

wide.

The Welch A i l y n C o m p a n y which developed the first video-endoscopes presented this instrument to the A m e r i c a n Society o f Gastroenterology 4 years ago.

Since that time, m a n y o f these instruments are cur- rently in use worldwide. In 1986, 25 o f these instru- ments were sold in France, a n d it is likely that a b o u t one h u n d r e d more will be acquired in 198Z

B A S I C P R I N C I P L E G O V E R N I N G T H E O P E R A T I O N O F T H E E L E C T R O N I C

V I D E O E N D O S C O P E t~ V.E. )) A study o f the C . D . C . 9

The operation o f an electronic video endoscope is similar to that o f a ~ Solid-State ~ camera or ~ Chip Camera ~. This f u n c t i o n requires the use o f C . D . C . or ~ Charge Device Coupling ~.

I4I.-I4I. Boyle a n d G.-E. S m i t h invented this equip- m e n t in 1969, using a technique based on the proper- ties o f silicon, a light-sensitive semi-conductor.

Indeed, a p h o t o n which strikes an area o f silicon causes the release o f an electron a n d creates a positively-charge optic hole, a n d the entire process generates an electric current.

Current m e t h o d s miniaturization m a k e it possible to manufacture electronic targets having a reduced surface area.

These silicon targets together p e r m i t image analy- sis. Targets are separated f r o m each other by electri- cal circuits allowing the transfer o f electric charges :

- - the entire configuration o f targets a n d electrical circuits f o r m s a microprocessor k n o w n as a C.D.C.

(Charge device coupling) ;

h the target itself or p h o t o - d i o d e is k n o w n as Pixels (picture element). The n u m b e r o f pixels deter- mines the quality o f the image : the more pixels, the greater the c o m p l e x i t y a n d detail o f the electronic signal, thereby reproducing reality more closely.

B u t the more there are pixels in a C.D.C., the larger its size, and the m o r e difficult to miniaturize.

90 Volume 17 - N ~ 2 - 1987 Acta Endoscopica

Cet article des Editions Lavoisier est disponible en acces libre et gratuit sur archives-acen.revuesonline.com

(3)

Thus, in e n d o s c o p y a balance m u s t be f o u n d bet- ween the n u m b e r o f pixels a n d the size o f the C . D . C . T h e electronic video e n d o s c o p e ( E . V . E . ) :

T h e reduced size o f the C . D . C . (2.8 m m in diame- ter) e m p l o y e d by Welch A l l y n m a k e s it possible to place it at the distal e n d o f the e n d o s c o p e j u s t behind an objective whose f u n c t i o n is to concentrate the light on the area sensitive to it, which will then be analyzed.

T h e C . D . C . g e n e r a t e s v i d e o f r e q u e n c y signals which are received a n d t r a n s m i t t e d b y a simple elec- tronic cable to the d e c o d e r o f a television monitor.

A n E. V.E. includes the f o l l o w i n g c o m p o n e n t s :

-- an endoscope with a c o n v e n t i o n a l mechanical e l e m e n t holding a C . D . C . ;

- - a video-processor also e q u i p p e d with a system o f insufflation a n d light source ;

- - a T V m o n i t o r w h o s e definition determines the quality o f the picture.

A d v a n t a g e s o f this s y s t e m are e v i d e n t :

- - p i c t u r e definition is superior to that obtained with optic f i b e r s a n d theoretically, m a y be increased indefinitely ;

-- all o f the techniques available with electronics : storage, a n d transmission o f signals m a y be used.

Their value is vital to investigational a n d teaching applications f o r e n d o s c o p y a n d its increased use ;

- - in addition, the C . D . C . possesses a very wide spectrum, f r o m 300 n m to 1 000 nm, which is f a r greater than what is p o s s i b l e b y the h u m a n eye a n d

t h u s the theoretical p o t e n t i a l f o r computer-ass&ted image processing or image generation.

C r e a t i o n o f a specialized r e p o r t :

The relative c o m p l e x i t y required to learn the opera- tion o f this system, the e n o r m o u s diagnostic facilities which it p r o v i d e s are such that the editors o f A c t a E n d o s c o p i c have decided to p r i n t a special column to appear t h r o u g h o u t the y e a r a n d h a v e entrusted m e with this task.

This c o l u m n will include the f o l l o w i n g :

- - p a r t ! d e v o t e d to electronic video e n d o s c o p y (theoretical principles, practical applications, deve- l o p m e n t . . . ) ;

- - p a r t H will list, analyze, a n d p r o v i d e opinions on d i f f e r e n t French a n d f o r e i g n investigations on video cassette.

To be eligible, f i l m s m u s t include the f o l l o w i n g ele- m e n t s :

- - s u b j e c t : digestive e n d o s c o p y a n d its applica- tions ;

-- length : 10 to 30 m i n u t e s ;

- - g o o d technical quality, n o t a b l y with the ability to s h o w the f i l m using a Umatic 3 / 4 inch video cas- sette recorder ;

- - the f i l m is to be p r o d u c e d in French or a foreign language.

The endoscope used m a y be either o f the f o l l o w i n g types :

- - a f i b r o s c o p e a n d electronic camera s y s t e m ; - - or a video endoscope.

Acta Endoscopica Volume 17 N" 2 - 1987 91

Cet article des Editions Lavoisier est disponible en acces libre et gratuit sur archives-acen.revuesonline.com

Références

Documents relatifs

Considering the emphasis currently placed on Campylobacter Pylori in gastric pathology, we designed the present study to evaluate its presence in lymphocytic

Furthermore the impact of colonoscopy on the overall prognosis of colo-rectal cancer has been minimal, I believe Gilbertsen's results obtained by

Toutes les structures canalaires sont identifi6es en fonc- tion de leur rapport anatomique entre elles : cho- 16doque, Wirsung, veine porte, veine cave inf6-

H6mostase par injection d'6thanol d'un h6matome de la jonction eeso-gastrique.. Ad~nome papillaire intra-canalaire du

Giant common bile duct stone ; prevention of impaction and cholangitis with large caliber prosthesis.. Figure

The radiomorphological characteristics of Mirizzi syndrome are : dislocation, half-shaded or incomplete fillings and rarely obstruction of the common hepatic duct..

&#34;unit' at the stage o f its malignant transformation or before. As the number of micro-adenoma decreased with warfarine, it acts at the pre-adenomatous

This signal may be captured by the human eye but only within the spectrum o f visi- ble light and processed and interpreted by the brain, this whole process