• Aucun résultat trouvé

CANADIAN PLUMBING CODE 1980 REVISIONS

N/A
N/A
Protected

Academic year: 2021

Partager "CANADIAN PLUMBING CODE 1980 REVISIONS"

Copied!
2
0
0

Texte intégral

(1)

NATIONAL RESEARCH COUNCIL OF CANADA

ASSOCIATE COMMITTEE ON THE

NATIONAL BUILDING CODE

CANADIAN PLUMBING CODE 1980

REVISIONS

January 1984

Revisions are additional to those published in January 1983

Ottawa

Copyright

©

NRC

1941

- 2019

World

Rights

Reserved

©

CNRC

1941-2019

Droits

réservés

pour

tous

pays

(2)

REVISIONS

to the

Canadian Plumbing Code

1980

The following revisions to the Canadian Plumbing Code have been approved by the Associate Committee on the National Building Code.

Referenced Standards

Revise standards in the location shown in Column 4 of the following Table to conform to those in Column 3

Item No. 1 2 3 4 5 6 7 Col. 1 Revised Designation ANSI B16.26-1983, Cast Copper Alloy

Fittings for Flared Copper Tubes

ASTM A444-83,

Steel Sheet, Zinc-Coated (Galva- nized) by the Hot-Dip Process for Culverts and Underdrains ASTM B42-83,

Seamless Copper Pipe, Standard Sizes ASTM B88-83,

Seamless Copper Water Tube

CSA A257-M 1982, Standards for Concrete Pipe ASTM A53-82,

Pipe, Steel, Black and Hot- Dipped, Zinc-Coated Welded and Seamless

ANSI/AWWA C151-81, Ductile Iron Pipe, Centrifugally Cast in Metal Molds or Sand-Lined Molds for Water or Other Liquids

3

1980 Standard Designation

ANSI B16.26-1978, Cast Copper Alloy

Fittings for Flared Copper Tubes

ASTM A444-78,

Steel Sheet, Zinc-Coated (Galva- nized) by the Hot-Dip Process for Culverts and Underdrains ASTM B42-78,

Seamless Copper Pipe, Standard Sizes ASTM B88-78,

Seamless Copper Water Tube

CSA A257-1974,

Standards for Concrete Pipe CSA B63-1966,

Welded and Seamless Steel Pipe

CSA B131.13-1977, Ductile Iron Pipe, Centrifugally Cast in Metal Molds or Sand-Lined Molds for Water or Other Liquids

2 Code Reference 2.7.7.(1) 2.7.7.(2) 2.6.8.(1) 2.7.1 .(I) 2.7.4.(1) 2.5.3.(1) 2.5.3.(2) 2.6.7.(4) 2.6.4.(1) 4

Copyright

©

NRC

1941

- 2019

World

Rights

Reserved

©

CNRC

1941-2019

Droits

réservés

pour

tous

pays

Références

Documents relatifs

Au moyen de celui-ci, nous vérifions que (i) le modèle sémantique proposé est générique et extensible pour s’adapter à un large spectre de processus de fabrication, et que

The discrete Level Lines Shortening algorithm starts from a digital image, proceeds to the level lines extraction and to their independent evolution by discrete curve shortening

found  in  the  context  of  a  chromosome.  Adjacent  genomic  segments 

Inferior frontal sulcus (Broca’s area) is more mature on the left, whereas posterior superior temporal sulcus is more mature on the right hemisphere (Leroy et al., 2011).

One year later, they developed the gold-catalyzed approach for the synthesis of aromatic azo compounds directly from reductive coupling of the corresponding nitroarenes

The operational characteristics contain nine attributes: the preemption to evaluate if loading or unloading of a truck can be interrupted, the arrival time of