• Aucun résultat trouvé

THE USE OF THE ECM METHOD AS AN INDICATOR OF HIGH DUST CONCENTRATIONS IN POLAR ICE CORES

N/A
N/A
Protected

Academic year: 2021

Partager "THE USE OF THE ECM METHOD AS AN INDICATOR OF HIGH DUST CONCENTRATIONS IN POLAR ICE CORES"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: jpa-00226255

https://hal.archives-ouvertes.fr/jpa-00226255

Submitted on 1 Jan 1987

HAL is a multi-disciplinary open access archive for the deposit and dissemination of sci- entific research documents, whether they are pub- lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

THE USE OF THE ECM METHOD AS AN

INDICATOR OF HIGH DUST CONCENTRATIONS IN POLAR ICE CORES

C. Hammer

To cite this version:

C. Hammer. THE USE OF THE ECM METHOD AS AN INDICATOR OF HIGH DUST CONCEN- TRATIONS IN POLAR ICE CORES. Journal de Physique Colloques, 1987, 48 (C1), pp.C1-697-C1- 697. �10.1051/jphyscol:19871113�. �jpa-00226255�

(2)

JOURNAL DE PHYSIQUE

Colloque C1, suppl6ment au n o 3, Tome 48, mars 1987

THE USE OF THE ECM METHOD AS AN INDICATOR OF HIGH DUST CONCENTRATIONS IN POLAR ICE CORES

C.H. HAMMER

Department of Glaciology, Geophysical Institute, University of Copenhagen, DK-2200 Copenhagen, Denmark

Abstract : M~M: pH and dust concentration data obtained on the Dye 3, Camp Century and Byrd ice cores suggest, that the ECM data may be used to indicate high dust concentrations in polar ice cores i.e. higher than approx. 300)'-g/kg ice.

The dust concentration can only be inferred in a semi-quantitative way as the calibration curve shows a high scatter, especially for the internal 300-500 /c g/kg .

Various data from the 3 cores will be presented in order to illustrate the potential and limitations.

'ECM : Electrical Conductivity Method.

Article published online by EDP Sciences and available at http://dx.doi.org/10.1051/jphyscol:19871113

Références

Documents relatifs

We calculate the high-pressure melting temperatures of three potential components of the cores of giant planets, water, iron, and a simple silicate, MgSiO3, to investigate the state

Is the dating of the conductivity measurements carried out by counting 518(0) annual layers, or by matching the conductivity measurements themselves to known past

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des

Preuve. On pourra se reporter `a [Al4]. Pour prouver qu’il existe au plus trois configurations centrales colin´eaires, il faut appliquer le th´eor`eme de Rolle `a une fonction

Hence, the relative escape fraction can be estimated from the observed UV-to-LC flux density ratio if we know the intrinsic UV-to-LC luminosity density ratio and the IGM

One possible explanation for the benefit of this geometry is that by approximating the curvature of the streamlines with the vessel wall itself, the artery reduces or perhaps

To prove the only if part recall from Proposition 1 that if the ROC curve of the individual DM has both finite initial slope and non-zero final slope, the asymptotic

Although both these studies are steps towards obtaining more reliable constraints on the contribution of each main source region to the global dust cycle, remaining deficiencies