Aluminum-Oxide Humidity Sensors

N/A
N/A
Protected

Academic year: 2021

Partager "Aluminum-Oxide Humidity Sensors"

Copied!
10
0
0

Texte intégral

(1)

Publisher’s version / Version de l'éditeur:

Technical Note (National Research Council of Canada. Division of Building Research), 1970-01-01

READ THESE TERMS AND CONDITIONS CAREFULLY BEFORE USING THIS WEBSITE. https://nrc-publications.canada.ca/eng/copyright

Vous avez des questions? Nous pouvons vous aider. Pour communiquer directement avec un auteur, consultez la

première page de la revue dans laquelle son article a été publié afin de trouver ses coordonnées. Si vous n’arrivez pas à les repérer, communiquez avec nous à PublicationsArchive-ArchivesPublications@nrc-cnrc.gc.ca.

Questions? Contact the NRC Publications Archive team at

PublicationsArchive-ArchivesPublications@nrc-cnrc.gc.ca. If you wish to email the authors directly, please see the first page of the publication for their contact information.

NRC Publications Archive

Archives des publications du CNRC

For the publisher’s version, please access the DOI link below./ Pour consulter la version de l’éditeur, utilisez le lien DOI ci-dessous.

https://doi.org/10.4224/20358986

Access and use of this website and the material on it are subject to the Terms and Conditions set forth at

Aluminum-Oxide Humidity Sensors

Hedlin, C. P.; Nicholson, R. G.

https://publications-cnrc.canada.ca/fra/droits

L’accès à ce site Web et l’utilisation de son contenu sont assujettis aux conditions présentées dans le site LISEZ CES CONDITIONS ATTENTIVEMENT AVANT D’UTILISER CE SITE WEB.

NRC Publications Record / Notice d'Archives des publications de CNRC: https://nrc-publications.canada.ca/eng/view/object/?id=ecb6651c-414a-45fb-9abf-6a16b6f1d3c1 https://publications-cnrc.canada.ca/fra/voir/objet/?id=ecb6651c-414a-45fb-9abf-6a16b6f1d3c1

(2)

DIVISION OF BUILDING RESEARCH

542

NOTE

'IfE

C

JHI

N II

CAIL

·iJ

PREPARED BY C.

P.

Hedlin and R. G. Nicholson

CHECKED BY J.J.H. APPROVED BY N.B.H.

January 1970 PREPARED FOR Record Purposes

SUBJECT ALUMINUM-OXIDE HUMIDITY SENSORS

Some of the early development work on aluminum oxide humidity sensors was carried out by Jason(l)and, more recently, by Stover(2). The results of the latter work have been to develop the commercial de-vice which is the subject of this report(3).

The sensor consists of a piece of aluminum, about 0.010 in. thick, with a thin layer of anodized material, approximately 1/8 in. by 1/2 in. A porous layer of gold is placed over the anodized material so that moisture can be transmitted to the active substance. The gold layer and the parent material serve as electrodes. When subjected to changes in humidity, both electrical resistance and capacitance exhibit a marked change (Fig. 1).

The device can be used for measuring humidity in gases, and also for measuring moisture content in liquid hydrocarbons. For the latter case, the manufacturer states that it exhibits the same response whether the sensor is located above the material or immersed in it. The present report applies only to operation in air. The sensors described by Jason are sensitive to relative humidity; the present device, however, is claimed to be sensitive to the dewpoint temperature with no correction for ambient temperature being required.

Two types of sensors are manufactured: one for operation at dew-point temperatures ranging from -110°C to +20°C and at ambient temper-atures from -110°C to bO°C, and the other for operation at dewpoint'

(3)

2

-temperatures from +20°C to -t60°C and at ambient -temperatures up to 85°C. The sensor output is displayed on a panel having three ranges. Provision is made for the simultaneous use of five or six sensors, and for connection to recording equipment.

TEST RESULTS

Two sensors were used in the course of the investigation. These were of basically the same construction, except that in sensor No. 374 (an early model) the electrical lead was connected to the gold electrode by means of a fine wire. This wire was found to break frequently and was re-placed in the newer design (Sensor No. 2119) by a spring loaded contact.

Calibrations were conducted in the Atmosphere Producer at dewpoint temperatures down to _30°F. To test at dewpoint temperatures down to -100 ° F, air was passed through a saturator immersed in an alcohol bath.

It was then piped to a chamber containing the sensor at room temperature. At low dewpoint temperatures, sorption of moisture on the walls of the apparatus and leakage of small amounts of the moisture into the calibrating air stream will cause significant errors. Where it was possible in the second apparatus, stainless steel tubing and containers were used to mini-mize the sorption effect. In addition, the entire system was operated at a pressure above atmospheric so that flow would be outward if leaks existed. As a further precaution, the air leaving the calibration chamber was bubbled through a chamber of oil to avoid entry of ambient moisture through the exit tube.

Several calibration curves were found for sensor No. 2119 over a period of somewhat more than a year (Fig. 2). In finding a calibration point, the sensor was allowed to equilibrate for one half hour to one hour following a change in hUmidity level before a reading was taken. The calibration curves indicate either that some hysteresis exists or that the sensor does not reach equilibrium within the time allowed. Furthermore, substantial variations of calibration occurred over a period of a year. Whether these fluctuations are related to drift, occasioned by changes within the sensitive material, or by the problem of mechanical contact in the sensor, is not known. There is some evidence that movement in the spring loaded contact, causes variations in instrument response.

Two types of tests were made to assess the influence of sensor tem-perature on instrument output, and hence to test the validity of a single cali-bration curve involving instrument output and dewpoint temperature. In the first test, calibration curves were obtained at two sensor temperatures,

-22 ° F and 68°F (Fig. 3a). The calibration curves did not coincide as they should have done. In a second series of tests, the sensor temperature was varied for four fixed dewpoint temperatures: 30°F, O. 6°F, -11OF and -43°F (Fig.3b). The instrument response remained nearly constant for the 0.6°F

(4)

case, but varied substantially for the 300 F, _11 0F and _430

F cases. In these tests the indicated dewpoint temperature varied as much as

20Fo

with variations in sensor temperature; this demonstrates that serious errors will result from the use of an instrument output vs. dewpoint temperature curve if no corrections are made for sensor temperature.

The response rate of one of the sensors was tested by en-closing it in a small tubular capsule which could be opened suddenly.

The assembly was mounted in the Atmosphere Producer and the en-closed capsule space was flushed with air of known humidity. When it was opened, the sensor was im.rnediately exposed to the new humid-ity condition in the calibration chamber. With the sensor at 700

F and ambient dewpoint temperatures of 51 and 65°F, the time for the in-strument to go 63 per cent of the way to a new equilibrium point follow-ing a step change in humidity was approximately 2 seconds for both increasing and decreasing humidity (Fig. 4a). At 700 F and an anlbient dewpoint temperature of -29. 50F, the 63 per cent response time for humidity decreasing from 11.30

F dewpoint was approximately 20

seconds, and for humidity increasing from _600 F dewpoint it was about

50 seconds (Fig.4b). Instrument indication rather than humidity ratio was used for the ordinate, since calibration accuracy would not have permitted a more accurate result to be obtained by employing the latter. CONCLUSION

Tests were conducted on two commercial aluminum oxide humidity sensors. Calibration results showed some hysteresis and for one of the sensors, which was recalibrated several times, the

results changed significantly with time. The sensors were sensitive to humidity down to the lowest level tested, approximately -100° F dewpoint.

The results showed that there is a substantial temperature co-efficient and appropriate steps must be taken if errors are to be avoided. One possibility is to calibrate the sensor at the same temperature at which use is anticipated, and a second is to calibrate at more than one sensor temperature and apply a temperature correction.

REFERENCES

1. Jason, A. C. "Some Properties and Limitations of the Aluminum Oxide Hygrometer." Humidity and Moisture, Vol. 1, Reinhold 1965, p. 372-90.

(5)

4

-2. Stover, C. M. "Almninmn Oxide Humidity Element for Radiosonde Weather Measuring Use." Rev. Sci. Inst., Vol. 34, No.6,

1963, p. 632-35.

3. Chleck, D. and F.J. Brousaides. "A Partial Evaluation of the Per-formance of an Almninmn Oxide Hmnidity Element. "

(6)

oセ

\

_iᆪGsヲセtmjセMG _._ ____ . _カLセN -._-

mYFP

_ -'

t-JT

セQvャRFM ___ . .

\

ュァZTujinセum OXIc.- seセGUPrN 1*'2119

I

\

セReZQjNNDUrN⦅ セセrNatuiReM 70"F. )

\

\

CAPAClTA)Ja;-<:J.ltl. 0 0

--,

0 2£<SlsTAJJC& I

I

I

I 0./6

-

-J

I

, 0

I

i

oNiセ 0 - , 7

I

I

0' 0 III

f

Q:J2 6

-&

-:z

0 ;<t

ID

u.( oセj 5 ...} セ

.(\

"2

:(

J.:.-セ

v

/0

セQ.. l1..l j 0,08 4

/0

0

\

0.0.6 0

-

3

/

0 0 . Mセo 0" - -:20 4 0 dセ|vpPQセt .セャuᆪᆪ J -F. 60

(7)

0 ...8... I

I

I

I

i

f--I

I

L-I

-r---,

I \

eli

III

1

o

I 1 I

o

- Q セN, l - -

L

(8)

⦅セtセセOof[

セァZZ

CAL-l5l2ATJON cNvi\Zv・Mセ f':)R. SENSOR. fif!q

(9)

2.6 r . . . , . . , r []S_

-1--- -

---1--- - ---- ]

, ---i

i

I

-'1

I i i

i

---1

o

o

o

I

§ - -

B---

---=---]

o

-(d

eJ

Mセ

_---8

MMュMMセMfvMヲnMt

-

IIoF. '

o

0 - - - 0

-

- - - 0

----

- - - 0 - 0 1J€WPOINT -., -43°P'

"'---_J ._,

L

_

.:-2-0 .0 20 _ 1______ __ _ I __ 40 '60

J.,

80 100

(10)

- ' - - - - e - - - - _ _

A

-

-

-

- - e

65;., セーZZ^セ tQmセ AffQOy-. 2 "SEC'S.

'e_

--

--4.0

セQSセM⦅MMM⦅MMPセ

_ _ _ 0

______ 0

/ FIG.4a.

9

ゥzesヲoセ

cuQ\ts

ivセBGsᆪセ 21/9

FOQ STE-P O-lArv66'S IrJ HUMIDITY

UenセQR TEMp. 70°F amセVnt OOVPOIt'JT"]EMP. 5/"P cuQV& A 65' P cuQV6- B 2

35

0 i=-<t V

a

z

I- 3.0

rn

§

<fJ セ 2.5 r A[JS<:.·I-sEP セGZサGale O-lAtJCje -. --50 60 I 5 TI/1c :=h4f>SEO. Al/#ur£S 14 - ZO 30 tjセ eJ.A.pse:D) ウ・Zcoセds 2....0 F-- ----L ---l- - - L ---L.-

----JL

--+- --' '0 SCALE CHAセgeM

--FIG. 4-b.

l2E'6f{JNse cUr2v'E-

fOQ.

A 'STEP

CM.6N<;j&-sセqN

TEMP.

m"E

AMBIe..Jf I:;€IVP-JINT -295'F 6:5% セnウ[ TiMes A 2D "SEC'S. B . 50 SEC5. I'

I.

:e __

-I' I

-

-- -e__

e - -

.-- - -e

i

0 _ 0 - - - 0

1/

o--o--w

.____0--

Ii

---- () !

o

,i---AB'SCI'S'SA

ZZZセ[GfNM

DEIVpOIUT

Ii

\ - I/.3·F. oo.V INT

\

e

\ \

e

\

"

0.9 0.6 =0 w-- 4() TlftIE 。aセL SEColllD$ 60 f20 30 TJME セUᆪd J セLケGuLWsBs

Références

Documents relatifs

Ultimately success was achieved using a mammalian expression plasmid (monocistronic cassette, Figure 2A and Table S1A) transfected into COS-1 cells that allowed ectopic expression

Depending on porosity, hardness values were as much as four times higher (approximately) and modulus of elasticity u p t o ten times higher than corresponding values

▪ Nous abordons dans le premier les plantes condimentaires et leurs usages thérapeutiques. ▪ Dans le deuxième nous présentons des généralités sur les

gradient. This causes the gas to flow against the pressure gradient, and creates a slight pressure drop [58]. Cascading many of these stages allows the device to

At this time we have neither a microscopic particle motion based nor a hydrodynamic based quantitative interpretation of our experimental results, but we do provide evidence for

Thermodynamics of chemical reactivity in capillary systems The chemical behavior of capillary systems has been studied for more than ten years, and the theoretical framework is now

 لا تاجايتحاو تابغر عابشإ لفكي امب ةيكنبلا تامدخلا جيزم ميمصت نئابز شب رمتسم لك لا اضر لفكي نوبز لا تاجايتحلا ةيفاو ةساردب مايقلا دعب كلذو نئابز ؛  ؤسم

While this was justified by the fact that the NWoW project at BIC was primarily designed by a working group led by the HR Director and gathering HR Advisors (as the empirical