• Aucun résultat trouvé

Output Service Messages

Dans le document JES3 Messages (Page 146-156)

System Action: The writer is terminated if the message states CANCELED, or it is rescheduled if the message states RESCHEDULED.

Operator Response: If the writer was canceled, reissue the

·X,WTR command when the required devices are available.

Module: IATOSWD the character generation module name(s)

module is the copy modification module name; refchar is of the possible criteria:

Carriage tape or FCB (C)

Line Limit (L) Stacker (SS) Data set priority (P) Device type (T) Train Image (U)

When listed, the preceding keywords indicate that the attribute of the device cannot be changed except by an *ST ART or for an operator command to start processing. Otherwise, transmission of the data set begins.

System Action: Not applicable.

Operator Response: None. operator response before processing any data.

Operator Response: If DM701, DM719 or repositioning error prints, enter an *START, *REST ART, or *CANCEL command.

Explanation: An unrecoverable error occurred while trying to initialize the WTR DSP. indicated keyword or parameter was specified incorrectly.

System Action: Processing continues.

Operator Response: Reissue the command with the correct keyword or parameter. You may reissue the same command with only the error keywords or parameters specified or, you can issue an *CANCEL command to cancel the writer.

Module: IA TOSMP

IAT7011 devname (ddd), INVALID KEYWORD j KEYWORD (keywd) }

1 PARAMETER (prm) ,

FOR (em) COMMAND, REISSUE COMMAND.

Explanation: The keyword or parameter is not valid for the indicated command, or it cannot be processed at this time due to the current writer status.

System Action: Processing continues.

Operator Response: Reissue the command with the correct keyword or parameter. You may reissue the same command with only the error keywords or parameters specified, or you can issue an *CANCEL command to cancel the writer.

Module: IA TOSMP

IAT7012 devname (ddd), DUPLICATE KEYWORD (keywd), REISSUE COMMAND.

Explanation: This message is issued in response to an *ST ART,

*REST ARJ, or *CANCEL command. The indicated keyword was specified more than once in the command.

System Action: Processing continues.

Operator Response: Reissue the command with the keyword specified only once. If the first occurrence of the keyword was the correct one, you may reissue the command without the keyword. You may correct the command by reissuing it with only the error keywords or parameters specified, or you can issue an *CANCEL command to cancel the writer.

Module: IA TOSMP

IAT7013 devname (ddd), INVALID PARAMETER (prm) COMBINATION, REISSUE COMMAND.

Explanation: The command is not valid with the indicated parameter and a parameter which preceded it.

System Action: The writer waits for another command.

Operator Response: Reissue the command with only the parameters specified. Use the "not" option(/) to reset an unwanted parameter. You may reissue the same command with only the error keywords or parameters specified, or you can issue an *CANCEL command to cancel the writer.

Module~ IA TOSMP

IAT7014 devname (ddd), INVALID PARAMETER (prm) FOR KEYWORD (keywd), REISSUE COMMAND.

Explanation: The indicated parameter is not valid for the keyword.

System Action: The writer waits for another command.

Operator Response: Reissue the command with the correct parameter. You may reissue the same command with only the error keywords or parameters specified.

Module: IA TOSMP

IAT7015 devname (ddd), IMBEDED KEYWORD (keywdl) DETECTED FOR KEYWORD (keywd2), REISSUE COMMAND.

Explanation: The keyword (keywd 2) was detected while processing the parameter list for keyword (keywd 1).

System Action: The writer waits for another command.

Operator Response: The parameter scan attempted to locate the end of the parameter list. If the error was caused by a missing right parenthesis, reissue all keywords and parameters following the error on another command. You may reissue the same command with only the error keywords or parameters specified.

Module: IATOSMP

IAT7016 devname (ddd), EXCESSIVE SUBPARAMETERS FOR KEYWORD (keywd), REISSUE COMMAND.

Explanation: The number of parameters in the parameter list for the indicated keyword exceeded the maximum.

System Action: The writer waits for another command.

Operator Response: Reissue the command with a valid parameter list for the keyword. You may reissue the same command with only the error keywords or parameters specified.

Module: IA TOSMP

IAT7017 devname (ddd), SYNTAX ERROR DETECTED AT (text) REISSUE COMMAND.

Explanation: A syntax error was detected at the indicated location. Possible causes are a missing right parenthesis, an extraneous left parenthesis, or a keyword which is the first subparameter of a keyword parameter list.

System Action: The writer waits for another command.

Operator Response: Reissue the command with the correct syntax. Reenter all keywords and parameters.

Module: IA TOSMP

IAT7018 jjj (johno) ON devname (ddd) {JOB I DS=dsn I REQ}

{STARTED I RESTARTED I CANCELED}

[WITH LOAD]

[FROM {NOTE I CHECKPOINTl]

{

APRL={nnnnnnnn I INVALID}}

APRX={nnnnR I nnnnP I (nnnnP,nnnnR)}

Explanation: The writer has accepted an operator input command. The meanings of the terms in the message are as follows:

JOB

The requested action applies to all data sets for the job.

DS=dsn

REQ

The requested action applies only to the data set currently being processed by the writer. For a 3800 printer, the current data set is the data set that is visible at the transfer station. The name of the current data set is dsn.

The requested action applies to all data sets associated with the current device setup.

STARTED or RESTARTED or CANCELED Indicates which action is being taken.

WITH LOAD appears (nnnnnnnn), it indicates the approximate number of records left to be processed for all copies of

APRX=nnnnR or nnnnP or (nnnnP,nnnnR)

This field is included in the message for all printers on a system with MVS 3800 enhancements installed. The values in the field have the following meanings:

nnnnR

nnnP

Specifies the approximate number of records remaining in the current data set that have not

System Action: Processing continues.

Operator Response: None.

Module: IA TOSMP

IAT7019 devname (ddd) REPOSITIONING BY LINE INVALID FOR 3800

Explanation: A bus-out parity error occurred on the indicated printer or punch device.

Explanation: An error was detected on the indicated device.

The DATA LOST phrase is issued for a 3800 printer when a system-restart-required type of paper jam has occurred. If the message has DATA LOST, there has been a system restart

EQUIPMENT CHECK means either there was an equipment check or that after a unit check, sense byte 0 was set to X'OO'.

System Action: The writer waits for an operator command unless the CANCEL key was pressed on a 3800 printer (DATA CANCELED appears in the message).

Operator Response: If the cancel key was pressed on the 3800, then no response to this message is necessary. The data set whose page is visible at the transfer station has been canceled.

This is as if *CANCEL devname has been entered.

Clear the hardware condition as described for the system restart indicator in IBM 3800 Printing Subsystem Operator's Guide and then issue an *ST ART, *REST ART or *CANCEL command.

The command will apply to the data at the fuser. It is usually appropriate to issue *ST ART without further repositioning.

Module: IA TOSPN, IA TOSPR, IA TOSPS IAT7024 WRITER jjj (jobno) ON

ON devname

INTERVENTION REQUIRED

{ ~~~~sQg:i~~Y

INTERLOCK CONDITION ERROR

l

DATA LOST. WILL RESTART FROM FUSER ENTER *S,

*R OR *C COMMAND

Explanation: The indicated device was removed from ready status during writer processing, for the reason given.

System Action: The writer waits for an operator response.

Operator Response: Ready the device.

For the DATA LOST. WILL RESTART FROM FUSER ENTER *S, *R OR *C COMMAND condition, perform the operator response that is described for this phrase for message IAT7023. Note that after readying the 3800, a writer command must be entered.

Module: IA TOSPR, IA TOSPN, IA TOSPS IAT7025 WRITER jjj (jobno)

ON devname, .

{

INVALID UCS DATA CODE}

DATA CHECK

Explanation: An invalid UCS data code was detected on the printer using the universal character set feature, or there was a data check on a punch device.

System Action: The writer waits for an operator response.

Operator Response: Issue an *START, *CANCEL, or

*RESTART command.

Module: IA TOSPR, IA TOSPN

IAT7026 WRITER jjj (jobno) ON devname, UCS PARITY ERROR

Explanation: A parity error occurred on the printer using the universal character set feature.

System Action: The writer waits for an operator response.

Operator Response: Issue an *ST ART, *REST ART, or

*CANCEL command.

Module: IATOSPR

IAT7027 WRITER jjj (jobno) devname (ddd), COMMAND REJECT

Explanation: The channel program for the device whose address is ddd was rejected.

System Action: The writer waits for another command.

Operator Response: Issue an *START, *RESTART, or

*CANCEL command.

Module: IATOSPR, IA TOSPN IAT7028 WRITER jjj (jobno)

devname (ddd).

{

BUFFER LOAD CHECK }

ABNORMAL FORMAT RESET

Explanation: The writer has encountered a buffer load check or an abnormal format reset on the device whose address is ddd.

System Action: The writer waits for another command.

Operator Response: Issue an *ST ART, *REST ART, or

*CANCEL command.

Module: IATOSPR, IA TOSPN

IAT7029 WRITER jjj (jobno) devname (ddd),

PROGRAM/MACHINE CHECK PROCESSING I/O IN lOS

Explanation: An lOS error has been encountered while processing the writer's channel program.

System Action: The writer waits for another command.

Operator Response: Issue an *START, *RESTART, or

*CANCEL command.

Module: IATOSPR, IATOSPN

IAT7030 jjj(jobno) ON devname (ddd), SETUP = form-name (,U=xx]

[,

{~CB}

=xxx]

(,FL = xxx]

(,SS=x]

Explanation: The indicated job (jjj) is scheduled for device (ddd). The job's setup requirements are given by F=form-name, U=(UCS image name), C=(carriage tape name), FL=(flash name) and the stacker to thread. In the case of the 3800, SS will be C for the continuous forms stacker or S for the burster-trimmer-stacker. If message IEE7041 REPLY nn NOT OUTSTANDING is issued shortly after message IAT7030, JES3 could not automatically reply to message IAT7030. In this case the operator must reply. If the device is a 3800 and its

status is known to JES3, a code is displayed on the 3800

Thread forms to burster-trimmer-stacker. No changes are to be made to the forms or the forms overlay frame. PERMANENT I/O ERROR LOADING text2 NOT ENOUGH VIRTUAL STORAGE TO OPEN SYS 1.IMAGELIB

CANNOT OPEN SYS1.IMAGELIB TOO MANY CGM'S REQUIRED

INVALID TABLE REFERENCE CHARACTER FOR MODIFY

ERROR TRYING TO INITIALIZE PRINTER PERMANENT I/O ERROR ON SENSE

CHARACTER ARRANGEMENT ENTRY REFERENCED AN UNSPECIFIED CHARACTER SET

SETPRT SUBT ASK ABENDED, TO CONTINUE REPLY *S, *R, or *C DEVICE

NOT ENOUGH VIRTUAL STORAGE FOR PRINTER SETUP

UNEXPECTED ERROR FROM SETPRT. RC=xx FAILURE DURING SETTING UP OF PRINTER text2 specifies the following:

FCB=fcb;"'name UCS=ucs-name TRANSLATE TABLE

COpy MODIFICATION RECORD

COpy NUMBER

GRAPHIC CHARACTER MODIFICATION RECORD FORMS OVERLAY SEQUENCE CONTROL RECORD CHARACTER GENERATION MODULE previously-issued operator message with an IEC message number. If separator pages have not been suppressed

Operator Response: Notify the system programmer. Often the job separator pages have not been printed before this message appears. The failure commonly has been caused by the user, not the hardware, operator or system programmer.

If this message is printed on the printer, the pages containing the messages should be given to the submitter of the job. The installation may choose to adopt a policy of also giving the user information concerning solutions to common problems. For example there should be a list of which forms can be used with

Programmer Response: For UNEXPECTED ERROR FROM SETPRT, there is a probable programming error ih JES3 or in SETPRT.

Module: IA TOSPS

IAT7032 SETPRT SUB-TASK INVOKED FOR devname (ddd) (,COMMAND REJECTED) aborted. The only operator commands allowed during execution of SETPRT are *CANCEL or *REST ART commands without operands.

System Action: The subtask is entered, the SETPRT SVC is issued, and the subtask returns to the writer. While the subtask is active for the writer all messages to the operator are queued and will not be displayed until the sub task ends.

Operator Response: None, unless a command was rejected. In that case, wait for SETPRT execution to complete and issue the command again, or issue an *RESTART, ddd or an *CANCEL, ddd command.

Module: IA TOSPS

IA T7033 SETPRT EST AE FAILED

Explanation: A nonzero return code was received while attempting to establish an EST AE level for the SETPRT subtask.

System Action: The SETPRT subtask is terminated with a completion code of 2FB.

Operator Response: Issue the *ST ART or *REST ART command to start the writer. If this fails, notify the system programmer.

Module: IA TOSDR

IAT7040 OUTPUT SERVICE CHECKPOINT ERROR, SPINOFF DATA SETS MAY BE LOST.

Explanation: The output service driver was unable to read the checkpoint after a system restart. Any queued spinoff data sets are lost. This is probably a hardware I/O error.

System Action: The system continues processing.

Operator Response: Notify the system programmer.

Module: IA TOSDR

IAT7041 OUTPUT SERVICE INITIALIZATION ERROR, OUTPUT SERVICE INOPERATIVE.

Explanation: A system failure occurred during output service initialization processing. The failure may be due to a program check, a JSAM error, or an error in a JES3 general routine.

System Action: The output service function is placed in a permanent wait state. No more work is queued for output service writers.

Operator Response: Perform a system restart to reinstate output service processing.

Module: IA TOSDR

IAT7042 OUTPUT SERVICE ABEND PROCESSING JOB jjj (jobno), JOB REMOVED FROM OUTPUT SERVICE.

Explanation: Output service abnormally terminated while constructing output service elements for the indicated job.

System Action: The job is removed from the output service work queue, and its output data sets are not available for writer processing.

Operator Response: Cancel the job; or perform a system restart to have output service reprocess the job that was removed.

Module: IATOSDR

IAT7043 OUTPUT SERVICE START WRITER ABEND, AUTOMATIC WRITER FUNCTION

INOPERATIVE.

Explanation: Output service abnormally terminated while attempting to invoke a dynamic writer.

System Action: The automatic writer function of output service is disabled. No attempt is made to start writers to output devices which become available after this failure.

Operator Response: Issue *CALL,WTR commands for any writers to be used. To reinstate the automatic start writer facility, restart the system.

Module: IATOSDR

IAT7044 OUTPUT SERVICE UNKNOWN ABEND ERROR, OUTPUT SERVICE IN OPERATIVE.

Explanation: Output service abnormally terminated, but the failure could not be attributed to a specific unit of work.

System Action: The output service function is placed in a permanent wait state. No new work is queued for output service writers.

Operator Response: Perform a system restart to reinstate output service processing.

Module: IA TOSDR

IAT7045 OUTPUT SERVICE RECURSIVE ERROR, OUTPUT SERVICE INOPERATIVE.

Explanation: Output service has encountered a second failure during a single pass of a work queue.

System Action: The output service function is placed in a permanent wait state. No more work is queued for output service writers.

Operator Response: Perform a system restart to reinstate output service processing.

Module: IATOSDR

IAT7046 OUTPUT SERVICE ABEND PROCESSING JOB jjj [jobno), SPINOFF DATASET MAY BE LOST Explanation: Output service terminated abnormally while processing the job specified by jjj.

System Action: The data set is removed from the output service work queue and no further processing is done for this data set.

At the next JES3 restart, the data set is processed again.

Operator Response: None.

Module: IA TOSDR

IAT7050 JOB jjj jobno ON WTR dev PERMANENT DEV ERROR, SENS=sens

Explanation: The writer has received a permanent device failure indication from device dev. The sense bytes received are given in sens.

System Action: The device is varied offline. The current dataset is requeued from checkpoint.

Operator Response: Fix the device and then vary it online to JES3.

Module: IA TOSSN

IAT7051 JOB jjj jobno ON WTR DDN INTERVENTION REQD (CHNSZ=xxx)

Explanation: The writer has encountered a condition that requires operator intervention. If CHNSZ=xxx is given, the error occurred on a data set and xxx is the current chain size in effect. The intervention required condition at the physical device may cause the loss of data.

System Action: JES3 waits for operator response.

Operator Response: Issue an *REST ART,ddd command.

Module: IA TOSSN

IAT7052 DEVICE dev VARIED OFFLINE (IATOSSN) Explanation: The device identified by device name dev has been varied offline. This message is issued with messages IAT7050 and IAT7053.

System Action: Not applicable.

Operator Response: None.

Module: IA TOSSN

IAT7053 JOB jjj jobno ON WTR dev TERMINATE REQUESTED

Explanation: This message indicates one of the following three conditions: (1) the writer could not obtain a session to send data because a work station cancel was in progress, (2) work station cancel was detected while sending data, or (3) severe protocol error occurred on the session.

System Action: The data set is requeued from its checkpoint, and, in case of item 1, the device is varied offline.

Operator Response: None.

Module: IA TOSSN

IAT7054 JOB jjj jobno ON WTR dev PDIR REJJT FOR

{

FORMS=XXX TRAIN=yyy FCB=zzz SENSE=sens

Explanation: The writer setup header (PDIR) has been rejected for the indicated reason. If SENSE= is specified, the reject is unexpected.

System Action: JES3 waits for operator response, unless SENSE= is specified. In this case, processing continues with the PDIR function inoperative for this writer.

Operator Response: Issue an *REST ART command respecifying setup for the writer.

Module: IA TOSSN

IAT7055 JOB jjj jobno ON WTR dev

i

TRANSMISSION ERROR!

SENSE=sens

TI~~~:i:=~} ]

Explanation: The writer has encountered either a transmission error or has lost its session as indicated by the message text. If CHNSZ=yyy is given, the error occurred on an active data set where yyy is the current chain size.

System Action: For transmission errors, JES3 waits for operator response unless the error occurred on header or trailer pages. In this case processing continues. For session errors, the writer will attempt to obtain a new session.

Operator Response: If FCB= is given, it is likely that the FCB load sequence is not acceptable to the work station. In this case, restart the writer specifying an alternate FCB or enter an

*ST ART command to continue with the current FCB. In all other cases, restart the writer.

Module: IA TOSSN

IAT7056 JOB jobno ON WTR dev CONV ERR ON FCB=xxx, SPECIFY ALT FCB

Explanation: The FCB image obtained from SYSl.lMAGELlB cannot be converted to an SNA set vertical forms (SVF) sequence required to load the image.

System Action: JES3 waits for operator response.

Operator Response: Restart the writer and specify a new FCB.

Module: IA TOSSN IAT7060

{ { OSMP} devname diagfld } OSWD

devname, rqaddr, chnaddr, rcdsn, diagfld, in Explanation: This message is issued in response to any command after a *START, *RESTART or *CANCEL command with the D parameter specified. This message contains an eight-byte diagnostic field (diagfld) in the writer data area (IATODWD).

For 3800 printers with the 3800 MVS enhancements installed, rqaddr specifies the address of the RESQUEUE for the job currently at the writer; chnaddr specifies the address of the RESQUEUE for the job currently at the channel; rcdsn specifies the address of the most recent data set or start of transmission pending page queue (PPQ) entry. The rcdsn field is zero if the printer is not a 3800 The in field specifies the current index of WTRINDX.

System Action: Not applicable.

Operator Response: None Module: IA TOSMP, IA TOSWD

IAT7070 JOB (jobno) jjj REQUESTED INVALID NODE

IAT7070 JOB (jobno) jjj REQUESTED INVALID NODE

Dans le document JES3 Messages (Page 146-156)