DEMARRAGE/START/ANLAUF TENSION/VOLTAGE/SPANNUNG
D’APPLICATIONS THERMIQUES
COMPAGNIE INDUSTRIELLE FOLIO/FOLIO/SEITE NUMERO DE SCHEMA/DRAWING NUMBER/PLAN NR INDICE/INDEX/KENNZIFFER REFERENCES COMMANDE/ORDER REFERENCES/AUFTRAGSREFERENZ
1/2
3980889 33
CREATOR:
DATUM:
DATE:
REMPLACE/TAKE/ERSETZT MODIFICATION GEANDERT DURCH:
MODIFIED BY:
MODIFIE PAR:
REMPLACE PAR/TAKE BY/ERSETZT DURCH KENNZIFFER
INDEX INDICE
CLIENT/CLIENT/KUNDE LEGENDE/LEGEND/LEGENDE DATUM
DATE DATE
REFERENCE/REFERENCE/REFERENZ CREATEUR:
SPECIFICATION/SPECIFICATION/SPEZIFIZIERUNG APPAREIL OU UNITE/UNIT/GERAT ODER EINHEIT
DATE:
HERSTELLER: BE 25−03−99
17−04−00
RACCORDEMENT THERM.+PROGRAM.
ILZH 15 A 130
33
3950010.36 MODIF RAJOUTER ILZH 65−130
SAG
DELTADORE FILS NUMEROTES EN OPTION
OPTION KABEL NUMMERIERUNG NUMBERING OF WIRING IN OPTION
B C D E F G H I J
A
02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
01
ILZh UTR
Composants: Thermostat TA
Progammateur / Programmer
Compteur bleu EDF / EDF Counter
2 5 7 9 11
Terminal box UTR Bornier P V1 V2 N2 L2 N1 L1
X1
13
N 1
QT1
212
ENSEMBLE AQUACIAT / AQUACIAT ASSEMBLY RACCORDEMENT ELECTRIQUE / ELECTRICAL CONNECTION
MRS5−1.A
1 3
J4
2 1 2 4 5
J5
3
23
ILZH
1.230V.50HZ+Terre/Earth
N 1
QT2
225 30 31
N 1
QT3
23738
Programmer CLIMBOX 2 Programmateur CLIMBOX 2
1 2 3 4 5 6 7 8
N1
Remote info exit Sortie Tele info
COUNTER
COMPTEUR BLEU
22 21
DEMARRAGE/START/ANLAUF TENSION/VOLTAGE/SPANNUNG
D’APPLICATIONS THERMIQUES
COMPAGNIE INDUSTRIELLE FOLIO/FOLIO/SEITE NUMERO DE SCHEMA/DRAWING NUMBER/PLAN NR INDICE/INDEX/KENNZIFFER REFERENCES COMMANDE/ORDER REFERENCES/AUFTRAGSREFERENZ
2 /2 3980889 33
3 DELTA DORE
thermostat support Support Thermostat
3 4 5 1 2
B1
DELTA DORE thermostat support Support Thermostat
3 4 5 1 2
B2
ZONE 1
1 4 6 8 10
Terminal box UTR Bornier P V1 V2 N2 L2 N1 L1
X2
B C D E F G H I J
A
14 15 16 17 18
Terminal box UTR Bornier P V1 V2 N2 L2 N1 L1
X3
Ph
ZONE 2
DELTA DORE thermostat support Support Thermostat
3 4 5 1 2
B3
DELTA DORE thermostat support Support Thermostat
3 4 5 1 2
B4 N
N 1
QT
21.230V.50HZ+Terre/Earth
19 20
24 26 27 28 29 32 33 34 35 36
Terminal box UTR Bornier P V1 V2 N2 L2 N1 L1
X5
Terminal box UTR Bornier P V1 V2 N2 L2 N1 L1
X4
MC :Circulateur / Circulator RAG:Resistance antigel groupe
Compressor discharge sensor B5:Sonde freon echangeur plaque
Plate exchanger freon sensor B7:Sonde refoulement compresseur
OPTION PCR
BSC: Thermostat securite chaud 63˚C Boitier d’ambiance / Ambiant box
Hot safety thermostat
MV :Moteur ventilateur / Fan motor assembly Unit antifreeze heating element
FS :Controleur de debit / flow controller BS :Thermostat de securite / Safety thermostat
Bleu
2
Rouge 6
7
Noir5
1−21
KR1
3 49
1−17
1 3 5
KG
2 4 6Cd1
R1
R
MG
C S
10 13
46 1−20 PE2
1−22
KR3
3 412 15
R3
Fil pilote pilot wire
B4:sonde freon batterie / coil freon sensor B3:Sonde air exterieur / ext. air sensor B1:Sonde depart eau / Water outlet sensor B2:Sonde retour eau / Water return sensor
1−22
KR2
3 4R2
MC
Marron Brown
26
BlueBleu
F O
1−3 1−19
F O
1/5 1/21
F O
1/6
F O
1/8 1/22
BlackNoir 35
HP P
Option PCR 42
Report defaut neutre
2425 31
1−17
KG
13 1436
34 37 47
Cd2
0
MV YIC
A1KG
A2
46 1−13
RAG
Removely displayed neutral fault
Sans option PCR Without opt.PCR
43 44 45
CA
BSC BS
A2
KR1
A1
A2
KR3
A1 A2
KR2
A1
MODIFICATION:
REMPLACE PAR:
MODIFIE PAR: INDICE
TENSION:
No DE COMMANDE:
CLIENT:
DATE
REFERENCE:
APPAREIL:
D’APPLICATIONS THERMIQUES DATE:
COMPAGNIE INDUSTRIELLE
CREATEUR:
LEGENDE:
DESIGNATION:
APPAREIL OU UNITE:
FOLIO NUMERO DE SCHEMA INDICE
REMPLACE:
1 BE
21−06−00 11−09−00
1 COMP. 1 CIRCUIT .
ILZHE 15 A 30
02
02
3950010.36
BORNIER J1 MIS A JOUT (DEPLACEMENT BORNES)
BE
/2 3981047
3980726
FILS NUMEROTES EN OPTION
J3
MRS5.1
J4
MAIN CARD
CARTE PRINCIPALE
1 2 3 J5 1 2 3 4 5 J6 1 2 3 4 5 6 J7 1 2 3 J8
J1 1 2 3 4 5 6 7 8 9 10 11 12 J2 1 2 3 4 5 6 7 8 9 10 11 12
N 1
QG
2N 1
QR1
21
N P
PE1
CLIENT’S CONNECTION RACCORDEMENTS CLIENT
N 1
QR3
2C
B1
C
B2
N 1
QT
23
N 1
QR2
24 8
C D E F G H I J
11 14 16 17 18 19 20
46
C
B3
C
B5
30
C
B7
PCR
BP P
FS
D
FS
FS
32
Option 2 3
C
d’ambiance Boitier
1
1−21
KR1
1 2 1−22KR3
1 238
C
B4
21 22 23 28 2927 33 39 40 Marche froidMarche chaud Heating operation Cooling operation Hors gel batiment Relance a distance Remote relaunching Commun / CommonDelest/Relestage etages Load shedding/repowering of stagesBuilding antifrost
"Asservissement et commandes externes"
11
J2 12
du connecteur J2.
et de bonne qualite)
(Contact libre de toute polarite Raccorder un contact entre 11 et 12
Contact ferme −−> signal de relance a distance
Voir le manuel d’utilisation MRS5.1 paragraphe:
Pour les precautions a prendre pour le raccordement des entrees
PRECAUTIONS DE RACCORDEMENT / CONNECTION PRECAUTIONS
10 J2
9 J2
12 12
CA
8 J2
du connecteur J2.
12
du connecteur J2.
et de bonne qualite)
(Contact libre de toute polarite
Contact ferme −−> fonctionnement en delestage Contact ouvert −−> fonctionnement en relestage Enlever le pont entre 10 et 12
du connecteur J2 et y raccorder un contact.
DELESTAGE/RELESTAGE / LOAD SHEDDING/REPOWERING
Contact ferme −−> fonctionnement horsgel batiment et de bonne qualite)
(Contact libre de toute polarite Raccorder un contact entre 9 et 12 et de bonne qualite)
(Contact libre de toute polarite Contact ferme −−> fonctionnement froid
HORSGEL BATIMENT / FROST PROTECTED BUILDING
RELANCE A DISTANCE / REMOTE RE−LAUNCHING
Closed contact −−>unit on line Open contact −−>unit off line
(Good quality and polarity free contact)
"Servo−control and external controls"
See the MRS5.1 utilization brochure, paragraph:
For precautions to be taken for the inlets connection (Good quality and polarity free contact)
Connect a contact between 11 and 12 of connector J2
Closed contact −−>Remote re−launching signal
MODIFICATION:
REMPLACE PAR:
MODIFIE PAR: INDICE
TENSION:
No DE COMMANDE:
CLIENT:
DATE
REFERENCE:
APPAREIL:
D’APPLICATIONS THERMIQUES DATE:
COMPAGNIE INDUSTRIELLE
CREATEUR:
LEGENDE:
DESIGNATION:
APPAREIL OU UNITE:
FOLIO NUMERO DE SCHEMA INDICE
REMPLACE:
2 BE
21−06−00 11−09−00
1 COMP. 1 CIRCUIT .
ILZHE 15 A 30
02
02
3950010.36
BORNIER J1 MIS A JOUT (DEPLACEMENT BORNES)
BE
/2 3981047
3980726
FILS NUMEROTES EN OPTION
Open contact −−>repowering operation Closed contact −−>Load shedding operation (Good quality and polarity free contact) Closed contact −−>Anti−frost operation
must be lifted and a contact connected.
The shunt ’CA’ between 10 and 12 of connector J2 (Good quality and polarity free contact)
Connect a contact between 9 and 12 of connector J2 Closed contact −−>cooling operation
(Good quality and polarity free contact)
J2 7 12
du connecteur J2.
Contact ferme −−> fonctionnement chaud et de bonne qualite)
(Contact libre de toute polarite Raccorder un contact entre 7 et 12
MARCHE FROID / COOLING OPERATION MARCHE CHAUD / HEATING OPERATION
Configuration P04 valeur 1
C D E F G H I J
Raccorder un contact entre 8 et 12
J2 10 12
CA
EXTERNAL CONTROLS
Configuration P04 valeur 0
(Contact libre de toute polarite Enlever le pont entre 10 et 12 et de bonne qualite)
must be lifted and a contact connected.
The shunt ’CA’ between 10 and 12 of connector J2 Contact ouvert −−> groupe a l’arret
Contact ferme −−> groupe autoriser a fonctionner du connecteur J2 et y raccorder un contact.
CDE AUTOMATICITE / AUTOMATIC CONTROL
Configuration P04 valeur 0
Closed contact −−> Heating operation (Good quality and polarity free contact)
Connect a contact between 7 and 12 of connector J2
Configuration P04 value 1
COMMANDES EXTERNES
Connect a contact between 8 and 12 of connector J2
2−15
1 3 5
KR1
2 4 6R3 R2 R1
2−16
1 3 5
KR2
2 4 6R4 R5 R6
2−17
1 3 5
KR3
2 4 6R8
R7 R9
U V W
MP
Cable uniquement pour l’ILZHE 65
MODIFICATION:
REMPLACE PAR:
MODIFIE PAR: INDICE
TENSION:
No DE COMMANDE:
CLIENT:
DATE
REFERENCE:
APPAREIL:
D’APPLICATIONS THERMIQUES DATE:
COMPAGNIE INDUSTRIELLE
CREATEUR:
LEGENDE:
DESIGNATION:
APPAREIL OU UNITE:
FOLIO NUMERO DE SCHEMA INDICE
REMPLACE:
1 BE
27−06−00 11−09−00
1 COMPRESSEUR 1 CIRCUIT .
ILZHE 50 65
01
01
3950010.36
BORNIER J1 MIS A JOUR (DEPLACEMENT BORNES)
BE
/3 3981050
3980873
FILS NUMEROTES EN OPTION
2−12
1 3 5
KG
2 4 6U V W
MG
PE3
3 50HZ 400V 135N
246N
C D E F G H I J
1 3 5
QR1
2 4 6
1 3 5
QR2
2 4 6
1 3 5
QR3
2 4 6
1 3 5
QP
2 4 6
L1 2−03 N 2−03
1 3 5
QG
2 4 6
4
RAG
Noir12
Brown
MV1
Black Noir
17
BrownMarron
MV2
Cd2
Black
0
YIC
27
A2
KG
A1
F O
1−13 2−5
2−14
Cd1
Marron
92−12
21
KG
22
7
PE2
4 C
BA
RC
Blue Blue
14 38
A
2−14
21
22
P
1
HPD
4 2
11 13
Fil pilote pilot wire Report defaut neutre
38
Bleu Bleu
P HP
24 29
A2
KR1
A1 A2
KR2
A1
F O
1−19
F O
1−16 2−15
A2
KR3
A1
F O
1−22 2−16
Hot safety thermostat OPTION PCR
Boitier d’ambiance / ambiant box BA:Thermostat antigel groupe MP :POMPE / PUMP
YD :Vanne de demarrage
HPD:Pressostat de degivrage/antifrost pressostat RC :Resistance de carter/Crankcase heater
MV :Moteur ventilateur / Fan motor assembly BS :Thermostat de securite / Safety thermostat
BSC:Thermostat securite chaud 63˚C
A
382−09BSC
BS
Option PCR Without opt.PCRSans option PCR
539
CA
34 35 36
COMMANDE A DISTANCE RS485
RAG:Resistance antigel groupe Compressor discharge sensor B7:Sonde refoulement compresseur B5:Sonde freon echangeur plaque Plate exchanger freon sensor
Unit antifreeze heating element
B4:sonde freon batterie / coil freon sensor B1:Sonde depart eau / Water outlet sensor B2:Sonde retour eau / Water return sensor B3:Sonde air exterieur / ext. air sensor
FS :Controleur de debit / flow controller
0
YD
MODIFICATION:
REMPLACE PAR:
MODIFIE PAR: INDICE
TENSION:
No DE COMMANDE:
CLIENT:
DATE
REFERENCE:
APPAREIL:
D’APPLICATIONS THERMIQUES DATE:
COMPAGNIE INDUSTRIELLE
CREATEUR:
LEGENDE:
DESIGNATION:
APPAREIL OU UNITE:
FOLIO NUMERO DE SCHEMA INDICE
REMPLACE:
2 BE
27−06−00 11−09−00
1 COMPRESSEUR 1 CIRCUIT .
ILZHE 50 65
01
01
3950010.36
BORNIER J1 MIS A JOUR (DEPLACEMENT BORNES)
BE
/3 3981050
3980873
FILS NUMEROTES EN OPTION
Removely displayed neutral fault
J3
MRS5.1
J4
MAIN CARD
CARTE PRINCIPALE
1 2 3 J5 1 2 3 4 5 J6 1 2 3 4 5 6 J7 1 2 3 J8
J1 1 2 3 4 5 6 7 8 9 10 11 12 J2 1 2 3 4 5 6 7 8 9 10 11 12
N 1−23 L1 1−23
C
B2
2 1 8
C
B1
C
B4
C
B3
C
B7
23
C
B5
Option PCR
FS
D
FS
FS
2 3 C
d’ambiance Boitier
1
N 1
QT1
2 6C D E F G H I J
10 1615 18 19 20 26
2−12
KG
13 142−15
KR1
13 142−17KR3
13 14Marche chaud
BP P
25 Marche froid Cooling operation Hors gel batiment Building antifrost Relance a distance Commun / CommonRemote relaunchingDelest/Relestage etagesHeating operation Load shedding/repowering of stages
28 3231 30
"Asservissement et commandes externes"
11
J2 12
du connecteur J2.
et de bonne qualite)
(Contact libre de toute polarite Raccorder un contact entre 11 et 12
Contact ferme −−> signal de relance a distance
Voir le manuel d’utilisation MRS5.1 paragraphe:
Pour les precautions a prendre pour le raccordement des entrees
PRECAUTIONS DE RACCORDEMENT / CONNECTION PRECAUTIONS
10 J2
9 J2
12 12
CA
8 J2
du connecteur J2.
12
du connecteur J2.
et de bonne qualite)
(Contact libre de toute polarite
Contact ferme −−> fonctionnement en delestage Contact ouvert −−> fonctionnement en relestage Enlever le pont entre 10 et 12
du connecteur J2 et y raccorder un contact.
DELESTAGE/RELESTAGE / LOAD SHEDDING/REPOWERING
Contact ferme −−> fonctionnement horsgel batiment et de bonne qualite)
(Contact libre de toute polarite Raccorder un contact entre 9 et 12 et de bonne qualite)
(Contact libre de toute polarite Contact ferme −−> fonctionnement froid
HORSGEL BATIMENT / FROST PROTECTED BUILDING
RELANCE A DISTANCE / REMOTE RE−LAUNCHING
Closed contact −−>unit on line Open contact −−>unit off line
(Good quality and polarity free contact)
"Servo−control and external controls"
See the MRS5.1 utilization brochure, paragraph:
For precautions to be taken for the inlets connection (Good quality and polarity free contact)
Connect a contact between 11 and 12 of connector J2
Closed contact −−>Remote re−launching signal
MODIFICATION:
REMPLACE PAR:
MODIFIE PAR: INDICE
TENSION:
No DE COMMANDE:
CLIENT:
DATE
REFERENCE:
APPAREIL:
D’APPLICATIONS THERMIQUES DATE:
COMPAGNIE INDUSTRIELLE
CREATEUR:
LEGENDE:
DESIGNATION:
APPAREIL OU UNITE:
FOLIO NUMERO DE SCHEMA INDICE
REMPLACE:
3 BE
27−06−00 11−09−00
1 COMPRESSEUR 1 CIRCUIT .
ILZHE 50 65
01
01
3950010.36
BORNIER J1 MIS A JOUR (DEPLACEMENT BORNES)
BE
/3 3981050
3980873
FILS NUMEROTES EN OPTION
Open contact −−>repowering operation Closed contact −−>Load shedding operation (Good quality and polarity free contact) Closed contact −−>Anti−frost operation
must be lifted and a contact connected.
The shunt ’CA’ between 10 and 12 of connector J2 (Good quality and polarity free contact)
Connect a contact between 9 and 12 of connector J2 Closed contact −−>cooling operation
(Good quality and polarity free contact)
J2 7 12
du connecteur J2.
Contact ferme −−> fonctionnement chaud (Contact libre de toute polarite et de bonne qualite)
Raccorder un contact entre 7 et 12
MARCHE FROID / COOLING OPERATION MARCHE CHAUD / HEATING OPERATION
Configuration P04 valeur 1
C D E F G H I J
Raccorder un contact entre 8 et 12
J2 10 12
CA
EXTERNAL CONTROLS
Configuration P04 valeur 0
(Contact libre de toute polarite Enlever le pont entre 10 et 12 et de bonne qualite)
must be lifted and a contact connected.
The shunt ’CA’ between 10 and 12 of connector J2 Contact ouvert −−> groupe a l’arret
Contact ferme −−> groupe autoriser a fonctionner du connecteur J2 et y raccorder un contact.
CDE AUTOMATICITE / AUTOMATIC CONTROL
Configuration P04 valeur 0
Closed contact −−> Heating operation (Good quality and polarity free contact)
Connect a contact between 7 and 12 of connector J2
Configuration P04 value 1
COMMANDES EXTERNES
Connect a contact between 8 and 12 of connector J2