Diagnosis of the pipeline corrosion due to the inductive interference between high voltage

power line and buried pipeline

Touhami Omar, Ibtiouen Rachid, Ouadah M'hamed

Abstract : In this paper, we study the interference between high voltage power transmission line and buried pipeline. The induced voltage onto the pipeline was calculated for the horizontal and the vertical configuration of the power line, the existence of the earth wire, various separation distances between conductors of the power line, and various separation distances between power line and pipeline. This effect results in a corrosion process which we have proposed some solutions.

Keywords : Power lines, interference, induced voltage, induced current density, pipeline, AC Corrosion .

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

Keywords : Electromagnetic pollution, high voltage power line, induced current density, X70 steel pipeline, corrosion, Finite Element Method, Electrochemical impedance

A method to investigate the effects of the induced AC density on the corrosion and the CP performances of the X70 steel buried pipeline due to the inductive interference caused by

The induced voltage onto the pipeline was calculated for different separation distance between conductors, the existence of the earth wire, separation distance between transmission

In order to diagnose the effect of the electromagnetic pollution on the corrosion of the pipeline, the electrochemical impedance spectroscopy (EIS) measurements were used

Abstract: This paper diagnosis the effect of the AC current densities induced by the electromagnetic interference between high voltage power line and buried power line on the

Abstract—This paper diagnoses the effect of the AC current densities induced by the electromagnetic interferences between high voltage power line and buried power line on

The induced voltage onto the pipeline was calculated for the horizontal and the vertical configuration of the power line, the existence of the earth wire, various separation

Therefore, the assessment of the remaining life of these pipeline structures became increasingly importantto ensure the continuity of production and distribution operations..