• Aucun résultat trouvé

Method for diagnosis of the effect of AC on theX70 pipeline due to an inductive coupling causedby HVPL

N/A
N/A
Protected

Academic year: 2021

Partager "Method for diagnosis of the effect of AC on theX70 pipeline due to an inductive coupling causedby HVPL"

Copied!
1
0
0

Texte intégral

(1)

IET Science, Measurement & Technology

Volume 11, Issue 5, 2017, Pages 1-7

Method for diagnosis of the effect of AC on the X70 pipeline due to an inductive coupling caused

by HVPL

M.Ouadah, O.TOUHAMI, R.IBTIOUEN, M.Zergoug

Abstract: The inductive coupling between high-voltage power lines (HVPL) and buried pipelines has been an important research subject over the last decades. This coupling may result in alternating current (AC) on pipelines that may pose a serious threat to the pipelines due to corrosive effects and the cathodic protection (CP) performance. A method to investigate the effects of the induced AC density on the corrosion and the CP performances of the X70 steel buried pipeline due to the inductive interference caused by HVPL is proposed in this study. The method is based on the corrosion parameters of the X70 steel pipeline obtained by electrochemical measurements such as Tafel slopes, corrosion current densities, and corrosion potentials. These parameters were used as boundary conditions in the elaborated CP model. The results showed that, firstly, the induced AC density affects the electrochemical characteristic of the X70 steel and accelerates the corrosion of the pipeline. On the other hand, the impressed current cathodic protection is incapable of maintaining the CP potential level. However, some technical solutions were proposed to prevent the pipelines from AC corrosion and maintain the CP potential to an acceptable level.

Keywords : electrochemical analysis, interference, chemical variables measurement, power cables, steel, electric current measurement, Corrosion protection, pipelines

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

The induced voltage onto the pipeline was calculated for different separation distance between conductors, the existence of the earth wire, separation distance between transmission

In order to diagnose the effect of the electromagnetic pollution on the corrosion of the pipeline, the electrochemical impedance spectroscopy (EIS) measurements were used

The analyzed system as it is presented in Fig.1 has been simulated by finite elements method in order to calculate the distribution of the magnetic field and the

Abstract: This paper diagnosis the effect of the AC current densities induced by the electromagnetic interference between high voltage power line and buried power line on the

Abstract—This paper diagnoses the effect of the AC current densities induced by the electromagnetic interferences between high voltage power line and buried power line on

The induced voltage onto the pipeline was calculated for the horizontal and the vertical configuration of the power line, the existence of the earth wire, various separation

The induced voltage onto the pipeline was calculated for the horizontal and the vertical configuration of the power line, the existence of the earth wire, various separation

- We apply here the histogram method to the study of the electronic density of states of an impurity band in a semiconductor in the tight binding approximation.. The