• Aucun résultat trouvé

Impacts of Inductive and ConductiveInterference due to High Voltage Power Lines onMetallic Pipelines

N/A
N/A
Protected

Academic year: 2021

Partager "Impacts of Inductive and ConductiveInterference due to High Voltage Power Lines onMetallic Pipelines"

Copied!
1
0
0

Texte intégral

(1)

4ème Conférence Internationale sur le soudage, le Contrôle Non Destructif et l'Industrie des Matériaux et Alliages, IC-WNDT- MI'14

2014

Impacts of Inductive and Conductive

Interference due to High Voltage Power Lines on Metallic Pipelines

M. Ouadah, S. Bouyegh, M. Zergoug, C. Dehchar, B. Boussiala, O. Touhami, R.

Ibtiouen

Abstract : The electromagnetic interference caused by power transmission lines to oil and gas buried pipelines is under investigation for many years. Especially during fault conditions, large currents and voltages are induced. Even under normal operating conditions, voltages and currents are induced on the pipeline that may pose danger to working personnel or may accelerate the corrosion of the pipeline’s metal. In this research, the induced voltage in the oil buried pipelines due to the magnetic fields produced by nearby 400kV transmission lines have been computed on normal and fault conditions

Keywords : AC interference, Induced Voltages, Electric Power Transmission Lines, pipeline, AC Corrosion

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

The induced voltage onto the pipeline was calculated for different separation distance between conductors, the existence of the earth wire, separation distance between transmission

In order to diagnose the effect of the electromagnetic pollution on the corrosion of the pipeline, the electrochemical impedance spectroscopy (EIS) measurements were used

The analyzed system as it is presented in Fig.1 has been simulated by finite elements method in order to calculate the distribution of the magnetic field and the

The induced voltage onto the pipeline was calculated for the horizontal and the vertical configuration of the power line, the existence of the earth wire, various separation

Even under normal operating conditions, voltages and currents are induced on the pipeline that may pose danger to working personnel or may research, the induced

This research evaluates and analyzes the electromagnetic interference effects on oil and gas buried pipelines created by the nearby high voltage transmission lines. The aim is to

First we analyze the magnetic field for horizontal and vertical configurations, then we study the effect of the soil conductivity in the level of the induced voltage in

The structure of the relay protection device based on the microelectronic special-purpose processor was designed and the results of computer simulation of the proposed