• Aucun résultat trouvé

In-situ fibrillation of bio-based PLA/PA11 blends: Effect of the matrix elasticity on the morphology, rheology and mechanical properties

N/A
N/A
Protected

Academic year: 2021

Partager "In-situ fibrillation of bio-based PLA/PA11 blends: Effect of the matrix elasticity on the morphology, rheology and mechanical properties"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: hal-01342003

https://hal.inria.fr/hal-01342003

Submitted on 5 Jul 2016

HAL is a multi-disciplinary open access

archive for the deposit and dissemination of

sci-entific research documents, whether they are

pub-lished or not. The documents may come from

teaching and research institutions in France or

abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est

destinée au dépôt et à la diffusion de documents

scientifiques de niveau recherche, publiés ou non,

émanant des établissements d’enseignement et de

recherche français ou étrangers, des laboratoires

publics ou privés.

In-situ fibrillation of bio-based PLA/PA11 blends: Effect

of the matrix elasticity on the morphology, rheology and

mechanical properties

D Chomat, T Dadouche, Mohammed Yousfi, J Soulestin, M-F Lacrampe, P

Krawczak

To cite this version:

D Chomat, T Dadouche, Mohammed Yousfi, J Soulestin, M-F Lacrampe, et al.. In-situ fibrillation

of bio-based PLA/PA11 blends: Effect of the matrix elasticity on the morphology, rheology and

mechanical properties. 50ème congrès annuel du Groupe Français de Rhéologie, Oct 2016, LILLE,

France. �hal-01342003�

(2)

50ème congrès annuel du Groupe Français de Rhéologie, Lille (France), October 25 - 27, 2016

In-situ fibrillation of bio-based PLA/PA11 blends: Effect of the

matrix elasticity on the morphology, rheology and mechanical

properties

D. Chomat, T. Dadouche, M. Yousfi, J. Soulestin, M-F. Lacrampe and P. Krawczak

Mines Douai, Department of Polymer and Composite Technology & Mechanical Engineering (TPCIM), 941 rue Charles Bourseul, CS 10838, F-59508 Douai, France

Email : marie-france.lacrampe@mines-douai.fr

Keywords: Immiscible polymer blends, fibrillation, viscosity ratio, elasticity ratio

Abstract:

Microfibrillar polymer / polymer composites constitute a particular kind of multiphase polymeric materials in which the minor phase is in the form of filaments dispersed in the continuous phase and behave like fibrillar meltable solid particles. Compared to traditional composites, the polymer/polymer composites are light weight recyclable materials. However, the achievement of the microfibrillar structure requires the respect of a number of conditions. In particular, the two polymer components forming the blend should have appropriate rheological characteristics, allowing the formation of reinforcing fibrils [1]. In the flow conditions, the viscosity and elasticity ratios between the dispersed phase and the matrix should be suitable. In this study, bio-based PLA/PA11 80/20 w/w blends with and without a reactive chain extension agent (CE, 0.5 and 1wt%) were prepared by melt extrusion (at 200°C) followed by injection molding (at 180 °C, just below the melting temperature of PA11) using an injection molding apparatus. The effect of the matrix elasticity on the morphology and rheological properties of resulted microfibrillar blends was highlighted. SEM analysis showed that the morphology of the blend was predominantly nodular or totally fibrillar without and with the CE agent respectively. The results showed also a significant increase in the viscosity and elasticity of the blends prepared in the presence of the chain extension agent. On the other hand, the ductility increases compared with pure PLA (with an elongation at break greater than 80% against only 10% for neat PLA), without scarifying meanwhile the stiffness [2].

Left (PLA)/(PA11) ) extrudate and right (PLA+1% chain extension agent) /(PA11) extrudate after dissolving PLA matrix.

[1] D. Chomat. Elaboration et mise en forme de composites microfibrillaires par fibrillation in-situ: optimisation de la microstructure et des propriétés mécaniques résultantes, Thèse de doctorat, Mines Douai, 2013

[2] B.J. Rashmi et al., Toughening of poly(lactic acid) without sacrificing stiffness and strength by melt-blending with polyamide 11 and selective localization of halloysite nanotubes. Express Polymer Letters, 9(8), 721–735, 2015

Références

Documents relatifs

En bref, selon la représentation courante qu’on s’en fait, les hassidim semblent évoluer en vase clos et vivre sous le contrôle strict de leur communauté apparemment

Simultanément, une étude complémentaire par microscopie à force atomique des reliefs induits dans les deux matériaux (Fig. 2-a et b) a permis de comparer les structures

Après quelques sondages sur différents sujets dans la banque de données JICST(E), nous avons pensé que les résultats obtenus pour le domaine touchant les réseaux neuronaux pouvait

Object Oriented Programming Event Driven Programming GUI Programming Learning to program D:\DOC\HomePage\tutor\tutcont.htm Page 2 of 202 08/11/2004 Recursion - or doing it to

5, the current device limitation is thus the leakage to the underlying slab waveguide for large diameter devices and the disk sidewall scattering losses for small diameter devices..

1) Développer un modèle de formation continue du personnel scolaire des écoles primaires d’un même secteur, basé sur une communauté d’apprentissage professionnelle

We show that input de- termined automata form a robust class of timed languages, in that they are (a) determinisable, (b) effectively closed under boolean operations, (c) admit

C’est ainsi qu’il se retrouva, moins d’une heure plus tard, en pleine course-poursuite sur la demande d’un haut gradé saphirien -saphirien, tout de même, alors que Fles était