Publisher’s version / Version de l'éditeur:
Vous avez des questions? Nous pouvons vous aider. Pour communiquer directement avec un auteur, consultez la première page de la revue dans laquelle son article a été publié afin de trouver ses coordonnées. Si vous n’arrivez pas à les repérer, communiquez avec nous à PublicationsArchive-ArchivesPublications@nrc-cnrc.gc.ca.
Questions? Contact the NRC Publications Archive team at
PublicationsArchive-ArchivesPublications@nrc-cnrc.gc.ca. If you wish to email the authors directly, please see the first page of the publication for their contact information.
https://publications-cnrc.canada.ca/fra/droits
L’accès à ce site Web et l’utilisation de son contenu sont assujettis aux conditions présentées dans le site LISEZ CES CONDITIONS ATTENTIVEMENT AVANT D’UTILISER CE SITE WEB.
Canadian Journal of Civil Engineering, 7, 4, pp. 651-656, 1980-12
READ THESE TERMS AND CONDITIONS CAREFULLY BEFORE USING THIS WEBSITE.
https://nrc-publications.canada.ca/eng/copyright
NRC Publications Archive Record / Notice des Archives des publications du CNRC : https://nrc-publications.canada.ca/eng/view/object/?id=0f8d29a1-5de1-43d1-a70f-0f08e5e19a72 https://publications-cnrc.canada.ca/fra/voir/objet/?id=0f8d29a1-5de1-43d1-a70f-0f08e5e19a72
NRC Publications Archive
Archives des publications du CNRC
This publication could be one of several versions: author’s original, accepted manuscript or the publisher’s version. / La version de cette publication peut être l’une des suivantes : la version prépublication de l’auteur, la version acceptée du manuscrit ou la version de l’éditeur.
Access and use of this website and the material on it are subject to the Terms and Conditions set forth at
Unbalanced snow distributions for the design of arch-shaped roofs in
Canada
TH1 National Research Conseil national
N21d
1
+
Council Canadade
recherches Canada11".
945
2 G,
UNBALANCED SNOW DISTRIBUTIONS FOR
THE DESIGN OF ARCH-SHAPED ROOFS IN
CANADA
i
by D.A. Taylor and W.R. Schriever
JL'"
9'c$
Reprinted fromCanadian Journal of Civil Engineering Vol. 7, No. 4, December 1980
pp. 65 1-656
DBR Paper No. 945
Division of Building Research
6
ANALYZED
NOTE
Unbalanced snow distributions for the design of arch-shaped roofs in Canada
D. A . TAYLOR AND W.R.
SCHRIEVERBuilding Structures Section, Division ofBuilding Research, National Research Council of Canada, Ottawa, Ont., Canada K I A OR6
Received December 12, 1979 Revised manuscript accepted July 25, 1980
This note examines in some detail the design snow loads on simple arches and curved roofs recommended in the 1977 Commentary on Snow Loads of the National Building Code of Canada. Empirical modifications that give more appropriate unbalanced snow loads for large-radius arches and that will alleviate the problems caused by some overconservative aspects of the 1977 design loads are presented. They have been accepted for inclusion in the 1980 commentary.
Cette communication donne certains details du calcul des surcharges dues a la neige sur toits en voiite simples recommande dans le Commentaire sur les surcharges dues a la neige 1977 du Code national du bliment. Des modifications empiriques qui donnent des surcharges de neige non equilibrees plus appropriees pour les toits en voDte a grand rayon et qui alltgent les problemes causes par certains aspects trop consewateurs du calcul des surcharges 1977 sont presentees. Ces calculs ont ete acceptes pour le Commentaire 1980.
Can. J. Civ. Eng., 7,651-656(1980)
Introduction * - - -
,/:**---- - \
There were some significant changes in the recom- mended unbalanced snow loads for simple cylindrical
r~3v~h
arched and curved roofs in Commentary H to the National Building Code of Canada (NBC) 1977. Further recommendations appear in the 1980 edition of the commentary. The purpose of this note is to
outline the thinking behind these changes.
7
In the 1977 Commentary on Snow Loads (NBC
1977) of the National Building Code of Canada a
I
I
new unbalanced snow distribution was introduced C A S E 1I
Ifor arched roofs to correct two unrealistic aspects of
the triangular distribution used in the 1975 com-
1
-
1
0 . 8 *
mentary (NBC 1975) (Fig. 1). Both tended to occur on short-radius highly curved roofs, e.g., Quonset-
type roofs, and were: (i) the profile of the snow sur-
I
face protruded unrealistically high above the crown
i
of the arch; and (ii) the maximum snow load waslocated at the edge or eave of the roof regardless of C A S E I1
the slope and without consideration of the fact that iA2.0
in some cases the slope was far too steep to retain snow.
Figure 2 from the 1977 commentary shows how the F O R - - h 1 U S E C A S E I O N L Y
first problem was solved: the top surface of the drift L 10 was limited to the level of a horizontal line through
the crown and the maximum load was limited to h 1
F O R - > - U S E C A S E I A N D I 1
twice the 30 year return ground load, So.' The second L 10
problem was alleviated by the load FIG. 1. Design snow loads on cylindrical arch-shaped roofs
in the 1975 commentary. (For roofs exposed to the wind on 'In the 1980 NBC g is replaced by So to avoid confusion all sides, all values of C, marked with an asterisk (*) may with g = 9.81 m/s2 (gravitational acceleration). be reduced by 25%.)
@I980 National Research Council of ~a"adal~onsei1 national de recherches du Canada
')-?ti
5z~(
I
652 CAN. J. CIV. ENG. VOL. 7, 1980
obtained in this manner by the usual slope-reduction factor,
p:
where a is the slope of the tangent to the surface at the point considered.
Despite the advantages of the 1977 over 1975 pro- visions for the common, approximately semi- circular, cylindrical buildings, the 1977 recommen- dations proved to be rather conservative when applied to large-radius arches with wide spans in areas with low to moderate ground loads. This problem was exacerbated when these loads were applied in Ontario to existing arenas. Some curved roofs that were upgraded to satisfy the 1975 com- mentary might not have passed if checked again 2 years later against the 1977 loads. Of course, unless design loads are always revised downwards, there will inevitably be situations where new structures will be designed for more stringent conditions than existing structures. In this case, however, the 1977 changes were not introduced with the intention of increasing the design volume of snow on the roof. The data, although not plentiful, did .not justify an increase; hence a further modification of the loads for the 1980 code appeared warranted.
Background
Most designers would agree that recommended snow distribution should remain relatively simple while approximating the distributions observed on curved roofs. Unfortunately, one of the difficulties is that there are very few field measurements of maxi- mum accumulations. This is due mainly to the diffi- culty in obtaining such measurements, e.g., arriving at the site before snow slides off steeper roofs, obtaining measurements of depth and density safely on steep surfaces, and having the manpower and money to take such measurements across the country.
As there is a wide range of conditions that should be covered (climate, exposure, texture of roof sur- faces, spans, and curvatures), field observations should be considered as guides only and must be complemented by judgement and a general under- standing of air flow around buildings. Model tests (Isyumov 1971) in a water flume or wind tunnel using sand or some other substance as the "snow" mav
W I N D
-
I I I I C A S E I I c * 1 1 f l ! ~ ; l l i ~ / l j ! ~ ~ ~ l , ' . , 1 1 1 , 1 1 , , , , , ...
I
2.0 M A X I M U M W I N D W A R D S I D E C s = 0 L E E W A R D S I D E c =- y h x y = 1 5 p c f S o ( 2 . 3 5 k N l m 3 ) W H E N C > 2 . 0 U S E C = 2 . 0 T H E N C S = C . /3 h 1 F O R- -
U S E C A S E I O N L Y L 1 0 h 1 F O R - >-
U S E C A S E I A N D I 1 L 1 0FIG. 2. Design snow loads on cylindrical arch-shaped roofs in the 1977 commentary. (For roofs exposed to the wind on all sides, all values of C, marked with an asterisk (*) may be reduced by 25%.)
I
difficulty of simulating cohesive snow. Information on simple arched and curved roofs has been sum-
marized2 (see also Taylor 1979). 6
Discussion of Snow Loading in the 1977 Commentary
Before discussing modifications it is appropriate to examine the 1977 loading. Prior to 1977 the "uniformly distributed load" (Fig. 1, case I) was invariant across the span regardless of the slope, but this was changed in 1977 to reflect the influence of slope (Fig. 2). The significant change was to the un- balanced case I1 loading (Figs. 1, 2). Between 1965 and 1977 it was, as shown in Fig. 1, a triangle inde-
also be an important qualitative supplement but must 2Taylor, D. A. Snow loads for the design of cylindrical
NOTE 653 ( C ) o t s i h n c f ruoM [ R O W N , n 0 5 1 0 15 b ( D I S T A N C E F R O M C R O W N , m D I L f A I C L i R 0 l . l C P M k nl 2 4 6 1 l o 5 : r 4
"
-z z 0 3 , 2 7 z I 0 0 5 1 0 1 5 2 0 2 5 3 0 35 0 1 0 2 0 3 0 4 0 I 0 D I S T A N C E F@UM C R 0 8 N . I t D I S T A N C E F R O M C R O W N n D I S T A N C E F R O M C R O W N , f t I € ) D I S T A N C E F R O M C R O W N m D I S T A N C E F R O M C R O W N . I 1 , - , 15 20 5 iza-
czDISiAbCf FROM LROWN, I t
FIG. 3. Comparison of unbalanced snow load distributions according to the 1975 (-
-
-) and 1977 (-) commentaries. (20 psf ,-- 0.96 kPa.)pendent of the shape of the curved surface: the maxi- mum load, twice the 30 year return ground load (So), was always at the edge or eave of the roof regardless of the slope.
In 1977, however, the load distribution that applied to continuously curved arched roofs was made a function of the shape and slope of the roof, of So, and of the snow density, y. In addition it was noted in the commentary for the first time that ground drifts at the base of the arch on either side or both sides of the structure should be considered. These ground drifts will not be considered here.
Figure 3 a-f illustrates the unbalanced snow loads on a variety of curved (circular arc) roofs. Figure 3a shows that for all values of So, the 1977 distribution gave lower volumes of snow than the 1975 distribu- tion for the smaller Quonset-type (approximately semi-circular) roof. For a somewhat larger roof (Fig.
3b) this is true only for ground loads above 30 psf (1.4 kPa) and remains true for structures of in- creasingly larger spans for increasingly higher ground loads (Fig. 3 c-f). As the radii increase, a plateau of constant load, 2So, appears first in Fig. 3b when So = 20 and 30 psf (0.96 and 1.4 kPa) and for So = 20, 30, and 40 psf (0.96, 1.4, and 1.9 kPa) in Fig. 3c, etc. It is this plateau that results in the in- crease over the 1975 loads for the larger spans in areas of low to moderate So. The longer the span and the lower the So, the heavier will be the extra load represented by the plateau.
Figure 4 shows the relationship between So, y, and x, the distance measured horizontally from the crown to the point at which the load reaches 2S0. The maximum possible length of the load plateau is obtained from the same diagram assuming that the slope at the eaves is 130". For example, a hockey
CAN. J . CIV. ENG. VOL. 7, 1980
y =SNOW DENSITY
x = DISTANCE FROM CROWN OF CIRCULAR ARCH TO POINT AT WHICH Cs=2.0 I S REACHED USING CASE I I I N THE 1977 NBC p = LENGTH OF THE PLATEAU
I N WHICH CS=2.0 R = RADIUS OF THE ARCH S o Z M YEAR RETURN GROUND LOAD
(psfl 120 psf = 0.96 kPa)
FIG. 4. A study of the onset and maximum possible length of the C, = 2.0 load plateau using the 1 9 7 7 distributions.
h
E'-
-
- - h w ~ h w 2 0 L I Z L 1 2 h 1 F O R - & - U S E C A S E 1 O N L Y L 1 0 h 1 F O R - > - U S E C A S E S I A N D I 1 L 1 0 C A S E I!
I
0 I I W I N D W A R D S I D E C S = 0 L E E W A R D S I D E C =ThX
.
y = 1 5 p c f 5 0 ( 2 . 3 5 k N l m 3 Y h x W H E N-
> 2 . 0 U S E C = 2 . 0 S O T H E N C S = C . /3 I F T H E T O T A l S N O W L O A D P E R U N I T L E N G T H OF B U I L D I N G ( P E R P E N D I C U L A R T O T H E S P A N ) I N C A S E I 1 E X C E E D S S n . L l 2 C A S E S 111 A N D I V M A Y B E U S E DINSYEAD-'
OF C A S E I 1 C A S E 111 0 C A S E I Vofi
FIG. 5. Modified snow loads on arch-shaped roofs accepted for the 1 9 8 0 commentary. (For roofs exposed to the wind on all sides, all values of C, marked with an asterisk (*) may be reduced by 25%.)
arena might typically have a span, L, equal to the radius R of about 125 ft (38 m). If y is 15 pcf (2.35 kN/m3), then the plateau length would vary from about 0.3R to 0.1R for So = 20-80 psf (0.96-3.8 kPa), respectively.
Empirical Changes to the Unbalanced Loading in the 1977 Commentary
( a ) S o = 20 p s f ( 0 . 9 6 k P a l ( 6 . 1 a) S o = 4 0 p s f 11.92 k P a J . . .
fifj;p
(10.7 rnl/F<
(6. I m) i t . 1 mJ 40' (12.2 m) 70' (21.3 m) 80' (24.4 m) 1977 1977 Ic) ( d l z S o = 6 0 p s ff i
s o = 8 0 p ~ f6
110.7ml/fi
2
tn( 2 . 8 7 k P a l ( 6 . 1 m) la. I en) 13.83 k P a l b . l m . ib.1 m~
.40' (12.2 m) 70' (21.3m) 80' (24.4 m) 40' (12.2m) 70' 121 3 ml 5U' 124.4 m )
FIG. 6. Scaled drawings of the recommended design snow distributions on five arch-shaped roofs. (Broken lines represent 1980 distributions, cases I11 and IV. The total snow loads represented by each distribution (solid lines) are shown as a percentage of SOL.)
656 CAN. J. CIV. ENG. VOL. 7. 1980
ments for the 1980 commentary to reduce the size of this "plateau" rather than to wait many years for changes based on field data.
A number of ideas were checked by calculation using a linear elastic matrix analysis of two struc- tures, a bow-string trussed arch with a radius and span of 118 ft (36 m) and rise of 16 ft (3.9 m) and a Quonset-type arch of radius and rise equal to 35 ft
(10.7 m) and span 70 ft (21.4 m), both with So = 30
and 60 psf (1.4 and 2.9 kPa).
From these calculations it seemed that any sophis- ticated solution would really be arbitrary and diffi- cult to justify. The best approach at this stage seemed to be a simple addition in the commentary of one or two load cases that could be used in those situations in which the 1977 loading resulted in overconserva- tism (a long plateau at 2So resulting in a total load >SoL/2). As available data indicate that the maxi- mum load sometimes forms between the crown and edge of the roof, rather than along the edge, two new empirical loadings, cases I11 and IV, were proposed to the Standing Committee on Structural Design of the Associate Committee on the National Building Code. These new loadings limit the total volume of snow to the amount used prior to 1977 (SoL/2), an amount that seems reasonable in the light of experience, and they can be used by the designer in lieu of case 11. In this case, however, cases I11 and IV must be considered.
Case 111 (Fig. 5) is similar to the unbalanced loads recommended between 1965 and 1975 (Fig. 1, case 11); the only difference is that the load decreases where the slope exceeds 30°, according to the slope-
reduction factor
p.
Hence the total load is<
S,L/2.The case IV distribution in Fig. 5, an isosceles triangle with the maximum load at span and with the load falling linearly to zero at the crown and the edge, results in a total load of SoL/2. Hence, C, is
independent of
P.
The decision to use cases I11 and IV was based on
an evaluation of five roofs each for four different ground loads. The distributions are as shown in Fig. 6 a-d. From the figures the use of a total load of
s,L/~ to determine when to change from the case I1 to the case III/IV loading seemed appropriate. It follows that the total unbalanced snow load on these
arch-shaped roofs will always be 5 S0L/2.
Summary
To avoid the apparent overconservatism of the unbalanced snow loads of the 1977 commentary on some arch-shaped structures, the introduction of two new load cases (I11 and IV) and a limiting total load of SoL/2 indicating when to use them is adequate for the time being. A more consistent approach giving
the variation of design snow loads for the full range ,
,
of sizes of curved roofs would be superior but will probably not be achieved until more data are col- lected. Model experiments simulating blowing snow in a wind tunnel or water flume may help, but field data collected throughout Canada will still be required.
Readers are encouraged to send to the authors case histories of snow accumulations on or against arch-shaped or, indeed, any shaped roof.
This is a contribution from the Division of Building Research, National Research Council of Canada and is published with the approval of the Director of the Division.
ISYUMOV, N. 1971. An approach to the prediction of snow loads.
Ph.D. thesis, The University of Western Ontario, London, Ont., Research Report BLWT-9-71.534 p.
NATIONAL BUILDING CODE OF CANADA. 1975. Commentary H,
snow loads. I n Supplement No. 4 to the National Building
Code of Canada, 1975. National Research Council of Canada, Ottawa, Ont., NRCC 13989, pp. 117-130.
1977. Commentary H, snow loads. I n Supplement No. 4
to the National Building Code of Canada, 1977. National Research Council of Canada, Ottawa, Ont., NRCC 15558, pp. 69-83.
TAYLOR, D. A. 1979. A survey of snow loads on the roofs of
arena-type buildings in Canada. Canadian Journal of Civil Engineering, 6, pp. 85-96.