Optimal Stochastic Excitation for Linear Flaw Detection in a Solid Material.

N. HOUHAT, S. MENIGOT, T.BOUTKEDJIRT, R.Drai, JM. GIRAULT

Abstract: The field of ultrasonic nondestructive testing has known a great development during the recent years. In order to increase the faw detection sensitivity, many improvements have been made in the equipment and the sensors technology. In the present work, the optimal command which maximizes the flaw detection is investigated experimentally. A parametric optimization consisting of finding the optimal excitation frequency which maximizes the Euclidean distance between a reference medium and a medium with a linear faw has been obtained automatically by using the gradient descent algorithm. Moreover, the waveform excitation optimization has been considered. A set of stochastic signals have been transmitted to the medium. A closed loop optimization process based on a genetic algorithm allowed to find the optimal excitation without a priori knowledge on the shape of the signal. This optimal excitation converged to a sinusoidal pulse with the optimal frequency found by the parametric optimization.

Keywords : Optimal command, nondestructive testing, Gradient descent algorithm, Genetic algorithm, Ultrasound

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

Assuming that a plasmon is excited along a silver layer interface, at a wavelength of 1.06 gm, and that the nonlinear medium is carbon disulfide, a refractive index

requires that an upper bound is fixed to the pulse distortion, not only for a particular envelope Eo( 7" ) but for a set of envelopes providing a basis

Starting from the available Kramers-Kronig relations for natural optical activity and the rigorously determined static value of the chirality pseudoscalar (in the Tellegen

Comparison between rate coefficients (in units of cm 3 s −1 ) for the collisional deexcitation of CF + by para-H 2 obtained in this work and those obtained by Denis-Alpizar

The sheath edge calculated with the non-ionizing sheath model does not coincide with the position of the emission peaks, which suggests that a significant fraction of the ionization

It involves a shift in the usual quantities used to draw FRFs: instead of computing the stochastic response for a given excitation frequency, this work adopts a constant phase point

Rate coefficients for temperatures ranging from 5 to 150 K were computed for all hyperfine transitions among the first 15 rotational energy levels of both ortho- and para-NH 2

Deterministic frequency response diagrams for the mean sdof damped oscillator plus variation of (A,C) amplitude and (B,D) phase when ω 2 0 varies around operating points (a)–(d) using