• Aucun résultat trouvé

Towards a new method for cardiac tissue velocity measurements using MRI, comparison with echocardiography

N/A
N/A
Protected

Academic year: 2021

Partager "Towards a new method for cardiac tissue velocity measurements using MRI, comparison with echocardiography"

Copied!
4
0
0

Texte intégral

(1)

HAL Id: inserm-00932140

https://www.hal.inserm.fr/inserm-00932140

Submitted on 16 Jan 2014

HAL is a multi-disciplinary open access

archive for the deposit and dissemination of

sci-entific research documents, whether they are

pub-lished or not. The documents may come from

teaching and research institutions in France or

abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est

destinée au dépôt et à la diffusion de documents

scientifiques de niveau recherche, publiés ou non,

émanant des établissements d’enseignement et de

recherche français ou étrangers, des laboratoires

publics ou privés.

Towards a new method for cardiac tissue velocity

measurements using MRI, comparison with

echocardiography

Christophe Meyer, Pierre-André Vuissoz, Jacques Felblinger, Laurent

Bonnemains

To cite this version:

Christophe Meyer, Pierre-André Vuissoz, Jacques Felblinger, Laurent Bonnemains. Towards a new

method for cardiac tissue velocity measurements using MRI, comparison with echocardiography.

Jour-nal of Cardiovascular Magnetic Resonance, BioMed Central, 2014, 16 (Suppl 1), pp.P44.

�inserm-00932140�

(2)

P O S T E R P R E S E N T A T I O N

Open Access

Towards a new method for cardiac tissue velocity

measurements using MRI, comparison with

echocardiography

Christophe Meyer

2,1*

, Pierre-André Vuissoz

2,1

, Jacques Felblinger

1,4

, Laurent Bonnemains

1,3

From 17th Annual SCMR Scientific Sessions

New Orleans, LA, USA. 16-19 January 2014

Background

Echocardiography is currently the gold standard for cardiac tissue velocity measurement [1]. Phase contrast MRI with multiple excitations averaging has been pro-posed as an alternative solution [2]. In this study, we used a central k-space line phase contrast sequence [3] to acquire real-time velocity curves and compared them to echocardiography.

Methods

Eighteen healthy volunteers underwent cardiac MRI examination on a Signa HDxt 3T scanner (General Elec-tric, Waukesha). A phase contrast sequence modified to acquire only the central k-space line was used in a mid-ventricular small axis scan plane with through-plane velocity encoding during 128 heartbeats. The frequency encoding direction was angulated to encompass the

projection of the left ventricular outflow tract plane (Figure 1). Relevant parameters were: 256-point fre-quency k-space size, 35 cm FOV, 1 view per segment, 150 cm/s velocity encoding and 7 ms TR. Data were Fourier transformed into 1D+t image space, subjected to SVD decomposition for automatic spatial segmentation and finally automatic temporal domain peak detection. This process lead to the measurement of four durations for each heartbeat (RR): IsoVolumic Contraction (IVC), Systolic Ejection (SE), IsoVolumic Relaxation (IVR), and Diastolic Diastasis (DD). For every cardiac cycle, the results of the automatic detection were quality con-trolled by a physician who could either discard the data, correct or accept it. Myocardiac Performance Index (MPI) [4] was computed as (IVC+IVR)/SE as well as normalized systole duration (IVC+SE)/RR and normalized diastasis duration DD/RR. These values were checked

2IADI, Université de Lorraine, Nancy, France

Full list of author information is available at the end of the article

Figure 1 (a) Placement of small axis plane (green) and frequency direction (red). (b) Time-space display of velocity data with automatically selected ROI (blue) corresponding to maximum spectral power in cardiac frequency band.

Meyer et al. Journal of Cardiovascular Magnetic Resonance 2014, 16(Suppl 1):P44

http://www.jcmr-online.com/content/16/S1/P44

© 2014 Meyer et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http:// creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

(3)

against similar indices assessed with tissue Doppler echo-cardiography performed a few hours before the MRI.

Results

Seven subjects were discarded due to low echocardio-graphic or MRI data quality (impossibility to measure all the durations). One subject was manually post processed due to failure of automatic detection and a total of 360 heart beats were also discarded. For eleven subjects, velocity curves similar to echocardiographic ones were obtained (see Figure 2). Within the set of 1048 remain-ing heart beats, fair correlation was observed between echocardiographic values and the median of accepted

MRI cardiac cycles: r-squared = 0.52 for MPI, 0.61 for systole and 0.74 for diastasis.

Conclusions

This new method provides velocity curves very similar to echocardiographic tissue Doppler ones and the measure-ments of duration of the main cardiac cycle components (systole, diastasis) as well as MPI were well correlated. This paves the way for the observation of beat to beat intra-subject variability of cardiac indices.

Funding

None.

Figure 2 (a) Example of velocity curve obtained from MRI computed as mean velocity in ROI of Figure 1 (blue). Cardiac cycle (RR), IsoVolumic Contraction (IVC), Systolic Ejection (SE), IsoVolumic Relaxation (IVR) and Diastolic Diastasis (DD) are depicted on the curve. (b) Similar velocity curve obtained from tissue Doppler echocardiography.

Meyer et al. Journal of Cardiovascular Magnetic Resonance 2014, 16(Suppl 1):P44

http://www.jcmr-online.com/content/16/S1/P44

(4)

Authors’ details

1IADI INSERM U947, Nancy, France.2IADI, Université de Lorraine, Nancy,

France.3CHU Nancy, Nancy, France.4CIC-IT 801, INSERM, Nancy, France.

Published: 16 January 2014 References 1. Nagueh: JASE 2009. 2. Meyer: MAGMA 2013. 3. Tei: JASE 1997. 4. Möller: JMRI 1996. doi:10.1186/1532-429X-16-S1-P44

Cite this article as: Meyer et al.: Towards a new method for cardiac tissue velocity measurements using MRI, comparison with

echocardiography. Journal of Cardiovascular Magnetic Resonance 2014 16 (Suppl 1):P44.

Submit your next manuscript to BioMed Central and take full advantage of:

• Convenient online submission

• Thorough peer review

• No space constraints or color figure charges

• Immediate publication on acceptance

• Inclusion in PubMed, CAS, Scopus and Google Scholar

• Research which is freely available for redistribution

Submit your manuscript at www.biomedcentral.com/submit

Meyer et al. Journal of Cardiovascular Magnetic Resonance 2014, 16(Suppl 1):P44

http://www.jcmr-online.com/content/16/S1/P44

Figure

Figure 1 (a) Placement of small axis plane (green) and frequency direction (red). (b) Time-space display of velocity data with automatically selected ROI (blue) corresponding to maximum spectral power in cardiac frequency band.
Figure 2 (a) Example of velocity curve obtained from MRI computed as mean velocity in ROI of Figure 1 (blue)

Références

Documents relatifs

Productions scientifiques acquises au cours de la thèse ... 15 Introduction générale ... La douleur du nouveau-né ... Physiologie de la douleur ... Manifestations et évaluation de

L’effet des propriétés de compactage sur les paramètres thermiques des sols compactés est étudié en réalisant des mesures au conductimètre thermique sur des

Besides the numerical confirmation of the blockade phenomenon when l 1 ≤ l c , numerical simulations indicate that the emergence of propagating wave in do- main (2) induces a time

The different channel width reflects a different ice-hull contact condition that, in turn, determines the ice force distribution along the hull surface and affects the global

same type of jobs, and as a result highly skilled labor works at a physical to human capital ratio of -^ whereas the ratio for low skill workers is kp. As a result, skilled-

Specifically, this thesis would compare the manufacturing costs, shipping costs, assembly time and cost, and space utilization of two designs: a modified version of

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des

Abstract - A convenient method for determining the velocity of a light emitting fast ion beam utilizing fore and aft Doppler shifts is described, and appli'cati'ons are