7th African Conference on Non Destructive Testing ACNDT 2016 & the 5th International Conference on NDT and Materials Industry and Alloys (IC-WNDT-MI)

2016

Monitoring of cracking in reinforced concrete beam Under Shear Loadings by using Digital Image Correlation (DIC) and Acoustic Emission

(AE)

BELBACHIR A, SYED-YASIR A, MATALLAH M, LOUKILI A

Abstract : in this paper, an experimental study is performed on reinforced concrete beams without transverse reinforcement. The kinematics of the diagonal crack was studied in beams, with a constant width of the cross section. The same longitudinal reinforcement ratio and the same shear-span ratio are retained. Three point bending tests are performed in order to obtain the global mechanical behavior. During these tests, strains in longitudinal reinforcement bars were recorded using strain gauges embedded on the steel surface. The Digital Image Correlation (DIC) technique is used to monitor cracking during mechanical loading, in order to measure the intrinsic parameters of the cracking process (crack opening, crack length, slip between lips of cracks) at different stage.

In the other face of the beams, sensors of the acoustic emission were placed to record the damage evolution and to locate the movement of the crack during test. Both AE and DIC are efficient techniques to study the failure process of reinforced concrete structures.

Keywords : reinforced concrete, Digital Images Correlation, acoustic emission, shear cracks.

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

Displacement jumps of the order of 1.5 voxel (1 voxel = 13.5 µm) are obtained at one of the corners of the crack, while the sample face average crack opening (i.e., discontinuity of

Identification of damage and cracking behaviours based on energy dissipation mode analysis in a quasi-brittle material using Digital Image Correlation.. Paul Leplay · Julien R´ethor´e

It is shown that despite using interfacial transition zone between steel bar and concrete, numerical modelling on RC beam still requires other aspects to

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des

Figure 15: Correlation chart representing absolute energy as a function of signals duration for a test conducted in the EFC 16 solution at pH 3.5 under 1bar H 2 S with an

Figure 11 : Comparative evolution of cumulative energy of AE events related to HIC for tests on different sweet service steels (X60, X65 and X70) at pH 4.5 and under 1 bar H 2

Also, the representation of the density of detected AE signals on the gauge length of the specimen versus the time of test (Figure 7) allowed locating the

Abstract: Shrinkage may lead to tensile stresses and cracking in reinforced concrete structures due to several mechanisms: gradients of drying shrinkage, restraint of autogeneous