• Aucun résultat trouvé

A DC/DC Buck Converter Voltage RegulationUsingAn Adaptive Fuzzy Fast TerminalSynergetic Control

N/A
N/A
Protected

Academic year: 2021

Partager "A DC/DC Buck Converter Voltage RegulationUsingAn Adaptive Fuzzy Fast TerminalSynergetic Control"

Copied!
1
0
0

Texte intégral

(1)

4th International Conference on Electrical Engineering and Control Applications (ICEECA2019) 2019

A DC/DC Buck Converter Voltage Regulation UsingAn Adaptive Fuzzy Fast Terminal

Synergetic Control

Noureddine Hamouda, Badreddine BABES, Mohamed MEZAACHE

Abstract : In this paper, an adaptive fuzzy fast terminalsynergetic voltage regulation for DC/DC buck converter isdesigned based on recently developed synergetic theory and aterminal attractor method. The advantages of presentedsynergetic control include the characteristics of finite timeconvergence, insensitive to parameters variation and chatteringfree phenomena. Rendering the design more robust, fuzzy logicsystems are used to approximate the unknown parameters in theproposed controller without calling upon usual modellinearization and simplifications. Taking the DC/DC buckconverter in continuous conduction mode as an example, thealgorithm of proposed synergetic control is analyzed in detail. Allthe simulation results demonstrate the effectiveness and the highdynamic capability of the proposed AF-FTSC control techniqueover the FTSC strategy

Keywords : synergetic control, fuzzy logic system, terminal technique, finite time convergence, DC/DC buck converter

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

A low value λ O2 means excessive oxygen depletion in the cathode (oxygen starvation) which results in the decrease of the stack voltage and the delivered power as well

Grâce au couplage, la somme des ampères x tours moyens est théoriquement nulle (pas tout à fait en pratique car le rendement de conversion ne peut pas être égal..

Abstract : In this paper, an adaptive fuzzy fast terminal synergetic voltage control scheme for DC/DC buck converter is proposed based on recently developed synergetic theory and

This is due to the resistance (ESR) in the inductor and power switches, and the diode voltage drop, that determine an upper limit on the duty cycle and thus the output

Consequently, one shall use an observer which provides on-line estimate of both i (t ) and its derivative. Such an observer can be designed using the sole output voltage

The Las Cienegas Adaptive Management Program has been ongoing for nearly ten years and has greatly benefited from having an enthusiastic stakeholder group involved

Unprecedented and highly stable lithium storage capacity of (001) faceted nanosheet- constructed hierarchically porous TiO2/rGO hybrid architecture for high-performance

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des