Damage and Fracture Mechanics: Failure Analysis of Engineering Materials and Structures

2009, Pages 405-413

Comparison of Simulation Methods of Pulsed Ultrasonic Fields Radiated in Isotropic Solids

W. Djerir, T. Boutkedjirt and A. Badidi Bouda

Abstract:

The modelling of pulsed ultrasonic fields radiated by transducers in materials of various types is of particular interest in industrial applications of non destructive testing. Knowledge of the ultrasonic field allows defining and optimizing the control conditions. For the calculation of harmonic and pulsed ultrasonic fields, various methods have been used such as exact, semi-analytical, asymptotic and purely numerical methods. In this work, these methods are reviewed for the case of a planar and circular ultrasonic source coupled to a semi-infinite isotropic solid. In the second part, the solution of a semi-analytical method, which uses particular approximations, is compared to that of an exact one. The numerical calculations achieved by using the exact method are very tedious but allow the interpretation of physical phenomena involved. In contrast to that, the semi-analytic one permits the calculations to be undertaken in a more reasonable time. However, Rayleigh waves and head waves are not revealed by this method.

Keywords : Ultrasound, NDT, Pulsed field, Isotropic Solid, Transducer.

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

Solution to the frictional contact problem via the method of memory diagrams for general 3D loading histories. Method of memory diagrams for mechanical frictional contacts subject

Therefore, in the present project, it appeared soon that steps 1 and 2 should be reversed, so that the comparison of simulated with experimental solubility data having allowed

The aim of this work is to deconvolve the spatial effects of the receiver hydrophone in order to reconstruct the pulsed ultrasonic field with a better spatial resolution.. Hereby,

Particularly, the displacement normal to its surface is spatially averaged because of the receiver finite size. In this study, we show using a numerical simulation, the effectiveness

When measuring the ultrasound field, the signal provided by the receiving transducer is affected by its spatial properties. Particularly, the displacement normal to its surface

The modelling of pulsed ultrasonic fields radiated by transducers in materials of various types is of particular interest in industrial applications of non destructive

The aim of this work is to deconvolve the spatio-temporal effects of the receiving chain (hydrophone, cable, oscilloscope...) in order to reconstruct the pulsed ultrasonic field

Namely, if we set the occupation numbers ni equal to the average values which they have between the initial and final states of the transi- tion, and carry out