Comparison of Simulation Methods of Pulsed Ultrasonic Fields Radiated in Isotropic Solids

N/A
N/A
Protected

Academic year: 2021

Partager "Comparison of Simulation Methods of Pulsed Ultrasonic Fields Radiated in Isotropic Solids"

Copied!
1
0
0

Texte intégral

(1)

Comparison of Simulation Methods of Pulsed Ultrasonic Fields Radiated in Isotropic Solids

W. Djerir1, 2, T. Boutkedjirt2and A. Badidi Bouda1

1Laboratory of Characterization and Instrumentation, Technical and Scientific Research Centre for Welding and control, BP64, Route de Dely Brahim, Chéraga, Alger, Algeria

2Faculty of Physics, USTHB, BP. 32, El-Alia, DZ-16111 Algiers, Algeria Abstract

The modelling of pulsed ultrasonic fields radiated by transducers in materials of various types is of particular interest in industrial applications of non destructive testing. Knowledge of the ultrasonic field allows defining and optimizing the control conditions. For the calculation of harmonic and pulsed ultrasonic fields, various methods have been used such as exact, semi- analytical, asymptotic and purely numerical methods. In this work, these methods are reviewed for the case of a planar and circular ultrasonic source coupled to a semi-infinite isotropic solid. In the second part, the solution of a semi-analytical method, which uses particular approximations, is compared to that of an exact one. The numerical calculations achieved by using the exact method are very tedious but allow the interpretation of physical phenomena involved. In contrast to that, the semi-analytic one permits the calculations to be undertaken in a more reasonable time. However, Rayleigh waves and head waves are not revealed by this method.

Keywords:Ultrasound, NDT, Pulsed field, Isotropic Solid, Transducer.

Références

Documents relatifs

Our contribution is twofold: (1) we refine and enrich the information extraction patterns existing in the literature by improvement of the semantic extraction of spatial features

High frequency ultrasonic devices for the evaluation of the viscosity of coconut water in a rapid and simple

Abstract - This paper presents an experimental technique for analyzing the propagation of transient ultrasonic patterns generated by broadband thickness-resonant discs in water

Particularly, the displacement normal to its surface is spatially averaged because of the receiver finite size. In this study, we show using a numerical simulation, the effectiveness

When measuring the ultrasound field, the signal provided by the receiving transducer is affected by its spatial properties. Particularly, the displacement normal to its surface

For the calculation of harmonic and pulsed ultrasonic fields, various methods have been used such as exact, semi-analytical, asymptotic and purely numerical methods.. In this

The aim of this work is to deconvolve the spatio-temporal effects of the receiving chain (hydrophone, cable, oscilloscope...) in order to reconstruct the pulsed ultrasonic field

The aim of this work is to deconvolve the spatio-temporal effects of the receiving chain (hydrophone, cable, oscilloscope...) in order to reconstruct the pulsed ultrasonic field