ECG-triggered high-pitch CT for simultaneous assessment of the aorta and coronary arteries

HACHULLA-LEMAIRE, Anne-Lise, et al.

Abstract

To study the image quality of ECG-gated-computed tomography (CT) acquisition with a high-pitch CT imaging for the exploration of both the aorta and coronary arteries.

HACHULLA-LEMAIRE, Anne-Lise, et al . ECG-triggered high-pitch CT for simultaneous assessment of the aorta and coronary arteries. Journal of Cardiovascular Computed Tomography , 2016, vol. 10, no. 5, p. 407-13

PMID : 27451049

DOI : 10.1016/j.jcct.2016.07.010

Available at:

http://archive-ouverte.unige.ch/unige:90651

Disclaimer: layout of this document may differ from the published version.

1 / 1

(2)

Research paper

ECG-triggered high-pitch CT for simultaneous assessment of the aorta and coronary arteries

Anne-Lise Hachulla

a,b,*

, Maxime Ronot

c,d,e

, St ephane Noble

b,f

, Christoph D. Becker

a

, Xavier Montet

a,b

, Jean-Paul Vall ee

a,b

aDivision of Radiology, University Hospitals of Geneva, Rue Gabrielle-Perret-Gentil 4, Geneva, Switzerland

bPulmonary Hypertension Program, University Hospitals of Geneva, Geneva, Switzerland

cDepartment of Radiology, APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Clichy, Hauts-de-Seine, France

dUniversity Paris Diderot, Sorbonne Paris Cite, Paris, France

eINSERM U1149, Centre de Recherche Biomedicale Bichat-Beaujon, CRB3, Paris, France

fCardiology Division, University Hospitals of Geneva, Rue Gabrielle-Perret-Gentil 4, Geneva, Switzerland

a r t i c l e i n f o

Article history:

Received 6 July 2016 Accepted 10 July 2016 Available online 12 July 2016 Keywords:

ECG-gated high-pitch protocol Iterative reconstructions Aortic CTA

Coronary CTA Cardiovascular imaging

a b s t r a c t

Objectives: To study the image quality of ECG-gated-computed tomography (CT) acquisition with a high- pitch CT imaging for the exploration of both the aorta and coronary arteries.

Methods: Eighty-four patients underwent high-pitch ECG-gated aortic CT without b-blockers with iterative reconstruction algorithms. Contrast-to-noise ratio (CNR) between vessels and adjacent peri- vascular fat tissue were calculated on the aorta and the coronary arteries. Dose-length-products (DLP) were recorded. Two blinded readers graded image quality of the aorta and the coronary arteries on a 3- point scale. Coronary artery stenoses were compared with coronary angiograms in 24 patients. Kappa values were calculated.

Results: High-pitch acquisition resulted in a mean DLP of 234±93 mGy cm(4.2 mSv) for an acquisition of the entire aorta, (mean 73±16 bpm). CNR for ascending aorta was 10.6±4 and CNR for coronary arteries was 9.85±4.1. Image quality was excellent in 79/84 patients (94%), and excellent or moderate but diagnostic in 1087/1127 coronary artery segments (96%). 74 significant stenoses were observed, and 38/

40 significant stenoses were confirmed by coronary angiography (K ¼ 0.91, Sensitivity ¼ 0.97, Specificity¼0.98).

Conclusion: High-pitch ECG-gated aortic CT with iterative reconstructions allows an accurate exploration of both aorta and coronary arteries during the same acquisition, with limited dose deposition, despite the lack ofb-blockers and relatively high heart rate. Radiologists need to be aware of the necessity to analyze and report coronary artery disease in aortic examination.

©2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

1. Introduction

The computed tomography angiography (CTA) of the aorta is a technical imaging challenge. One of the most important points is image quality, i.e. absence of artifacts, presence of vascular

attenuation and contrast-to-noise ratio (CNR). These factors are crucial to reach a high accuracy for the diagnosis of the aortic disease, but the management of motion artifacts in the ascending aorta is of critical importance. Indeed, up to 57% of false intimalflap leading to misdiagnosis of dissection are caused by motion arti- facts.1This is mainly explained by an insufficient temporal resolu- tion of conventional CT acquisitions.

Coronary-CT angiography has become a very useful technique for the depiction of coronary artery disease (CAD).2e5Identification of asymptomatic patients who are at high risk of developing CAD is of major importance. Such patients may undergo CT for other in- dications, for instance aortic diseases, and subsequently extraction of accurate coronary analysis from the aortic CTA would be of great Abbreviations:CAD, coronary artery disease; CNR, contrast-to-noise ratio; CTA,

computed tomography angiography; ECG, electrocardiogram; LAD, left anterior descending artery; LCX, left circumflex artery; LM, left main coronary artery; RCA, right coronary artery.

*Corresponding author. Radiology Division, University Hospitals of Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1211, Geneve 14, Switzerland.

E-mail address:anne-lise.hachullalemaire@hcuge.ch(A.-L. Hachulla).

Contents lists available atScienceDirect

Journal of Cardiovascular Computed Tomography

j o u r n a l h o m e p a g e :w w w . J o u r n a l o f C a r d i o v a s c u l a r C T . c o m

http://dx.doi.org/10.1016/j.jcct.2016.07.010

1934-5925/©2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

(3)

clinical value. However, CT acquisition parameters are different for aortic imaging and for coronary imaging. So, aortic exploration may not be optimal for the analysis of coronary arteries, and additional acquisition may be required. As a consequence, if the exploration of both the aorta and coronary arteries is required, the resulting dose deposition is significant.

The recent development of new generation dual-source CT, high-pitch CT and new iterative reconstructions have led to image improvement by decreasing movement artifacts, decreasing image noise and increasing CNR of vessels.6,7Published data addressing the ability of such protocols to allow accurate and combined ex- plorations of both aortic and coronary arteries during the same acquisition are scarce, especially with low radiation deposition and regardless of the heart rate.8e10

The purpose of this study was to evaluate the image quality and CNR of uniquely thoraco-abdominal ECG-gated acquisition with a high-pitch and iterative reconstructions algorithm for the explo- ration of both the aorta and coronary arteries.

2. Material and methods

2.1. Patient selection

This retrospective study was conducted in the radiology department of _. It was approved by the local institutional review board, and informed consents were waived.

The study was based on the CT data of 84 subsequent patients who underwent a contrast-enhanced CT of the complete aorta on the dual-source MDCT system from April to December 2013. CTA was performed for a suspicion of or a follow-up for aortic disease such as a dissection (n¼20, M/F: 16:4, mean age: 57±20); thoracic aortic (n¼15, M/F: 7:8, mean age: 66±14) or abdominal aneurysm

(n ¼ 39, M/F: 35:4, mean age: 74 ± 10) or in order to plan a transcatheter aortic valve replacement (n¼10, M/F: 4:6, mean age:

82±3). Patients therefore underwent coronary angiography when indicated for their management.

Thefinal study population consisted of 84 patients (62 males) with a mean age of 70±16 years.

2.2. CTA acquisition protocol

All examinations were performed on a second-generation, dual- source MDCT system (Somatom Definition Flash, Siemens Health- care, Forcheim, Germany). CT acquisition parameters were as fol- lows: pitch: 3.2; rotation time: 0.28 s; collimation:

6420.6 mm. An automated tube potential selection algorithm was used according to patient attenuation on the scout scan (CarekV) with a reference of 120 kVe250 mA, generating a kilo- voltage of 80e140 and modulated mAs according to patient attenuation on the scout scan. All patients received an injection of 120 mL intravenous contrast medium (Iohexol, 350 mg of iodine/

ml, GE Healthcare) followed by 50 mL salineflush at aflow rate of 6 mL/s. The acquisition was initiated with a bolus tracking (region of interest (ROI) placed in the ascending aorta; threshold: 100 HU, scanning delay: 15 s). The thoracic, abdominal and pelvic CT ac- quisitions were performed in the cranio-caudal direction after

synchronization to the ECG. Acquisition was designed to obtain diastolic images of the heart, i.e. by initiating the scanning so that the heart was scanned at 60% of the R-to-R-peak interval. Nob- blockers or nitrates were administered for heart rate control or coronary vasodilation.11 Supplementary unenhanced or delayed acquisitions were performed according to the clinical situation, especially for patients with treated abdominal aortic aneurysm or suspected dissection. But, only arterial phase was used to assess the feasibility of a combined assessment of both the aorta and the coronary arteries.

A thoracic and abdominal images data set was reconstructed with iterative reconstruction algorithms (SAFIRE®-strength 3ekernel I26f) with a section thickness and an increment of 1.5/

1 mm for the aortic analysis and 0.6/0.3 mm for the coronary artery analysis, respectively.

2.3. CT imaging analysis

2.3.1. Mean attenuation, image noise and contrast-to-noise ratio ROI were manually drawn to measure the attenuation in Hounsfield units (HU) and were made as large as possible but avoiding calcium plaques and stenoses. ROIs were placed: 1) in the ascending thoracic aorta, and abdominal aorta just previously mentioned the iliac bifurcation; 2) at the origin of coronary arteries i.e. left main coronary artery (LM), left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA);

and 3) in the adjacent perivascular fat tissue. Image noise corre- sponded to the standard deviation of the attenuation of the ascending aorta as previously described.10,12

CNR were also calculated at both the aortic levels and the origin of these four coronary arteries according to published data, as fol- lows10:

with attenuations expressed in HU.

2.3.2. Image quality and artifacts

Coronary arteries were analyzed according to the 17 segments of the American Heart Association13 using an external workstation (Vitrea®Workstation, Vital Image, Minnetonka USA). The RCA in- cludes segments 1e4, and segment 5 was defined as the LM. The LAD includes segments 6e8. Segments 9 and 10 correspond to the first and second diagonal branches and segments 11e15 to the LCX.

Segment 16 was assigned to the posterior left ventricular branch originating from the RCA. The intermediate artery, if present, was defined as segment 17. Because of normal anatomical variations, not all coronary artery segments were present in all patients.

All CT were reviewed by two independent radiologists (_ and _) with 6 and 20 years experience in cardiovascular imaging. Readers were asked to grade the image quality and presence of respiratory motion and heart motion artifacts using a semi-quantitative 3- point scale, as follows: a score of 1 indicated excellent image quality without motion artifacts; 2, a moderate image quality with minor blurring of the vessel wall but diagnostic image quality; and 3, non-diagnostic image quality with severe blurring of the vessel wall or doubling of vessel contours. This analysis was performed at the level of the aortic valve, ascending aorta, descending aorta, CNR¼ðmean vessel attenuationmean perivascular fat tissue attenuationÞ

standard deviation of perivascular fat tissue attenuation

A.-L. Hachulla et al. / Journal of Cardiovascular Computed Tomography 10 (2016) 407e413 408

(4)

abdominal aorta and for each coronary segment. For each segment, the presence of stenosis was assessed and graded as follows: score 1, non-significant stenosis; score 2, significant stenosis (75%); and score 3, non-assessable stenosis (blooming artifacts due to calcifi- cations or a stent). A coronary artery lesion was defined as the presence of either a significant stenosis (score 2) or a non- assessable stenosis (score 3). When a significant stenosis was identified, the type of plaque was graded as: 1, non-calcified pla- ques (soft orfibrotic); 2, mixed plaques; 3, calcified plaques.

Finally, base on the heart rate (65 bpm and>65 bpm), two sub groups were analyzed.

2.3.3. Estimation of radiation dose

The effective radiation dose was estimated from the mean of the CT Dose Index volume (CTDIvol) and with a method proposed by the European Working Group for Guidelines on Quality Criteria for CT14using the doseelength product and a conversion coefficient (k). Conversion coefficients (mSv/(mGy cm)) vary from 0.015 for the abdomen to 0.014 for the chest, and 0.019 for the pelvis. We used the mean of these different region-specific conversion coefficients (k¼0.017 mSv/(mGy cm)), as previously described.9

2.4. Coronary angiography analysis

The coronary angiography images were retrospectively reviewed by a cardiologist (_) with 10 years of experience in interventional cardiology, blinded to the CTA images. The operator was asked to assess the image quality using the above-mentioned scale. He was then asked to perform the same analysis of the 17 segments of the coronary arteries using the above-mentioned scale.

2.5. Statistical analysis

Normal distribution of the data was assessed through a Kolmogorv-Smirnov test. Values were expressed as means (stan- dard deviations), or medians (ranges) according to the distribution of the variable, and percentages, as appropriate. Inter-reader agreements were analyzed by calculating the intraclass correla- tion coefficient (ICC), and by using Cohen kappa statistics. All an- alyses were performed using the Statistical Package for the Social Sciences (SPSS) software (version 20.0, SPSS Inc., Chicago,IL,USA).

3. Results

3.1. Patients

Eighty-four adult patients (62 males, mean age 70±16 years (range 19e94)) were included. No patient was excluded due to poor image quality. Patients had a mean body mass index of 26±5 kg/m2

(16e44). The mean heart rate was 71±14 beats/min (49e113). The patients' characteristics are summarized in theTable 1. The mean scan length was 615±34 mm (540e690). The mean duration of data acquisition was 1.4±0.1 s (1.1e1.6).

A total of 24 patients (29%) subsequently underwent planned coronary angiography according to the clinical management strat- egy (identification of CAD on the CT scan, planned TAVR, or pre- operative assessment).

3.2. CT acquisition

3.2.1. Mean attenuation, image noise and contrast-to-noise ratio The mean attenuation was 526 ± 154 HU (301e977) in the ascending aorta, 531±153 HU (282e973) in the abdominal aorta.

The mean image noise was 31±6 HU (16e46). The mean CNR of the ascending aorta, and abdominal aorta was 20.3±4.6 (11.4e33.7) and 20.6±4.8 (11.8e34.9), respectively. The mean attenuation and the mean CNR of the coronary arteries are reported inTable 2.

3.2.2. Image quality and artifacts

Global aortic image quality was graded excellent in 80/84 pa- tients (94%), and moderate in the remaining 4 patients (6%). No CT was considered of non-diagnostic quality (score 3). Respiratory motion artifacts were observed in only one patient and were considered as moderate. In 63/84 patients (75%), the acquisition was heart-beat-artifact free. Mild heart motion artifacts were pre- sent in 21/84 patients (25%). Non-diagnostic heart motion artifacts were never observed. Inter-observer agreement for global image quality and presence of artifacts are detailed inTable 3.

A total of 1082 CT coronary artery segments were evaluated. The inter-observer agreement for image quality grading was substantial (k¼0.75). For reader 1, image quality was rated as excellent for 75%

(810/1082) of the segments, moderate for 19% (206/1082), and non- diagnostic for 6% (66/1082). For reader 2, image quality was rated as excellent for 68% (724/1057) of the segments, moderate for 23%

(242/1057), and non-diagnostic for 9% (91/1057). Overall, coronary arteries were visualized with diagnostic image quality (scores 1e2) in 1016 and 966 segments (94% and 91%) and in 51 and 43 patients (60% and 51%) for reader 1 and 2, respectively. 426/436 (98%) and 408/424 (96%) coronary segments were diagnostic (scores1-2) with a heart rate65 bpm versus 590/646 (91%) and 558/633 (88%) segments with a heart rate>65 bpm for reader 1 and 2, respectively (p<0.001 and p<0.001). This corresponded to 27/33 (82%) and 22/

33 (67%) patients versus 24/51 (47%) and 21/51 (41%) patients for reader 1 and 2, respectively (p¼0.006 and p¼0.027).

When considering all patients with at least one non-diagnostic coronary segment, 45% and 37% of patients had only one non- diagnostic segment; and 33% and 29% had two non-diagnostic segments for reader 1 and 2, respectively.

Non-diagnostic image quality was most frequently found in the second segment of the RCA, 11/50 (22%) and 14/50 (28%) with heart Table 1

Patients' characteristics.

Patients' characteristics (n¼84)

Age (years) 70±16 [19e94]

Gender M/F (%) 62/22 (74/26)

BMI (kg/m2) 26±5 [16e44]

Average heart rate (beats/min) 71±14 [49e113]

Coronary angiography (%) 24 (29)

Aortic disease (age, gender M/F, average heart rate)

- Dissection: n¼20 (24%) 57±20 yrs; 16/4; 71±15 bpm - Thoracic aortic aneurysm: n¼15 (18%) 66±14 yrs; 7/8; 73±14 bpm - Abdominal aortic aneurysm: n¼39 (46%) 74±10 yrs; 35/4; 69±15 bpm - TAVR planning: n¼10 (12%) 82±3 yrs; 4/6; 73±10 bpm BMI: body mass index; values are expressed as mean±standard deviation (range);

TAVR: transcatheter aortic valve replacement.

Table 2

Mean attenuation and Contrast-to-noise ratio (CNR).

Mean attenuation CNR

Ascending aorta 526±154 20.3±4.6

Abdominal aorta 531±153 20.6±4.8

RCA 485±162 19.0±5.1

LM 505±169 19.7±5.1

LAD 504±174 19.7±5.2

LCx 511±159 20.5±4.8

CNR: Contrast-to-noise ratio; LAD: left anterior descending artery; LCx: left circumflex artery; LM: left main artery; ns: non significant; RCA: right coronary artery.

Values are expressed as mean±standard deviation.

(5)

rate>65 bpm, but only 2/33 (6%) and 2/33 (6%) with heart rate 65 bpm (p¼0.06 and p¼0.02) for reader 1 and 2, respectively.

The inter-reader agreement was excellent for the RCA and LM (k¼0.83±0.07, and k¼1.0±0.0, respectively), and substantial for the LAD and LCX (k¼0.68±0.05, and k¼0.76±0.06, respectively).

Overall the ICC was 0.76. The details for each segment are reported inTable 4.

Overall, 74 coronary artery lesions were detected in 1082 seg- ments, corresponding to 51 significant stenoses, and 23 non- assessable stenoses due to blooming artifacts. Regarding the 51 significant stenoses, 20 (39%) were non-calcified plaques, 23 (45%) mixed plaques, and 8 (16%) calcified plaques. The inter-reader agreement for the identification of coronary lesions was excellent (k¼0.84±0.03, k¼1.0±0.0, k¼0.91±0.05, and k¼0.9±0.03 for the RCA, LM, LAD, LCX, respectively).

Coronary angiography revealed 39 significant stenoses. Four stenoses suspected on the CT images were not confirmed on the coronary angiography. They corresponded to non-assessable le- sions due to blooming artifacts. Conversely, four stenoses identified on the coronary angiography were missed on CTA images due to motion artifacts, notably on the second segment of the RCA. Overall, the agreement between CTA and coronary angiography was excellent (k¼0.91±0.06). Overall, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), and accuracy of CTA for the identification of stenosis were 90%, 98%,

88%, 99%, and 98%, respectively. Details of the agreement for each segment are given inTable 5.

3.2.3. Estimated dose deposition

The mean CTDIv was 3.4± 1.3 mGy and the mean DLP was 232±88 mGy cm for the complete aorta acquisition, corresponding to an effective dose of 3.9±1.5 mSv.

4. Discussion

The present study aimed at evaluating the image quality of CT angiography for the simultaneous analysis of the complete aorta and coronary arteries in patients suspected of having aortic disease.

Results showed that the use of dual-source CT with high-pitch and iterative reconstruction resulted in high image quality with limited artifacts and low dose deposition, and allowed combined analysis of the aorta and coronary arteries.

The possibility of a global analysis of both coronary and aortic abnormalities is a real challenge resulting from the combination of two different protocols. Dual-source CT scanners are characterized by two X-Ray tubes and two detectors offset by approximately 90. They offer an increased temporal resolution, almost twice that offered by single source CT scanners.

Several studies have demonstrated the added value of high- pitch on the image quality of ascending aorta CTA without ECG

Table 4

Image quality scores for all coronary artery segments.

RCA LM LAD LCx Inter. Total

Segment No 1 2 3 4 16 5 6 7 8 9 10 11 12 13 14 15 17

Nb of segments evaluateda

84 83 76 60 46 84 84 84 75 75 36 84 77 55 36 18 25 1082

Kappa value segments evaluated

1.00

±0.0 1.00

±0.0 1.00

±0.0 0.86

±0.06 0.95

±0.03 1.00

±0.0 1.00

±0.0 1.00

±0.0 0.94

±0.06 0.65

±0.12 0.80

±0.06 1.00

±0.0 0.69

±0.15 0.92

±0.05 0.88

±0.05 0.93

±0.05 1.00

±0.0 Image qualitya

Excellent (score 1)

62 41 48 39 33 81 76 65 59 58 30 63 56 40 23 14 22 810

Moderate (score 2)

19 29 18 15 9 3 8 18 10 14 6 14 16 11 9 4 3 206

Non diagnostic (score 3)

3 13 10 6 4 e e 1 6 3 e 7 5 4 4 e e 66

Intraclass Correlation Coefficient

0.96 0.96 0.97 0.90 0.87 0.90 0.80 0.84 0.92 0.82 0.86 0.93 0.93 0.92 0.92 0.76 0.91

Kappa value image quality

0.89

±0.05 0.86

±0.05 0.88

±0.05 0.70

±0.09 0.54

±0.11 1.0

±0.0 0.67

±0.13 0.68

±0.08 0.72

±0.08 0.60

±0.09 0.69

±0.15 0.83

±0.06 0.76

±0.07 0.72

±0.09 0.72

±0.1 0.60

±0.19 0.83

±0.16 Nb coronary

lesions

8 11 4 0 0 0 13 15 1 5 0 5 4 4 1 1 2 74

Kappa value lesions

1.0

±0.0 1.0

±0.0 0.74

±0.17 1.0

±0.0 1.0

±0.0 1.0

±0.0 0.91

±0.06 0.88

±0.07 1.0

±0.0 0.88

±0.11 1.0

±0.0 0.71

±0.15 1.0

±0.0 1.0

±0.0 1.0

±0.0 1.0

±0.0 1.0

±0.0

Nb stenosis 6 9 4 0 0 0 7 7 1 4 0 5 1 3 1 1 2 51

Non-calcified plaque

3 5 2 e e e e 2 1 1 e 1 e 1 1 1 2 20

Mixed plaque 3 4 2 e e e 4 3 e 1 e 3 1 2 e e e 23

Calcified plaque e e e e e e 3 2 e 2 e 1 e e e e e 8

LAD: left anterior descending artery; LCx: left circumflex artery; LM: left main artery; RCA: right coronary artery.

aValues are indicated as numbers of segments evaluated in 84 patients (n/84).

Table 3 Image quality.

Global quality Breathing motion Heart motion Aortic Valve Ascending aorta Descending aorta Abdominal aorta

Excellent qualitya 80 83 63 83 76 84 84

Moderate qualitya 4 1 21 1 8 0 0

Non diagnostica 0 0 0 0 0 0 0

Kappa 1.00±0.0 1.00±0.0 0.93±0.04 1.00±0.0 0.92±0.02 1.00±0.0 1.0±0.0

aValues are indicated as numbers of segments evaluated in 84 patients (n/84).

A.-L. Hachulla et al. / Journal of Cardiovascular Computed Tomography 10 (2016) 407e413 410

(6)

triggering, resulting in a sensitivity and a specificity of 100% for the diagnosis of aortic dissection.15,16More recently, Bolen et al. have shown that high-pitch CTA with ECG-triggering provides higher image quality of the aortic root and ascending aorta when compared with a non-ECG-synchronized standard-pitch CT.17Dual- source CT with high-pitch and no ECG triggering provided accurate motion-artifact-free imaging of the ascending aorta, but not of the coronary arteries.18Therefore a high-pitch protocol is insufficient if coronary artery analysis is required.

Because an ECG-triggered high-pitch protocol leads to signifi- cantly fewer coronary motion artifacts, ECG triggering is mandatory if coronary arteries are to be explored with the same acquisition.

The second generation of dual-source CT scan permits ECG-gated protocols with high-pitch up to 3.48. Such ECG-gated high-pitch protocols have been used to increase the speed of the acquisition, thus reducing heart motion artifacts, permitting the screening of CAD with a reduced radiation dose deposition.8Present-day ma- chines offer a high temporal resolution19allowing the acquisition of the complete aorta together with coronary artery imaging. Indeed, at such high-pitch, 9.6e11.6 cm in the z-axis, acquisition can be performed in 250e300 ms, corresponding to a scan of the entire heart volume during a fraction of a single heartbeat. As a conse- quence, step-motion artifacts are virtually inexistent20

ECG-gated aortic CT has already been used for the combined assessment of the aorta and the coronary arteries. Nevertheless, authors reported limitations especially for the analysis of the cor- onary arteries. Scharf et al., recommended the administration ofb- blockers,8 while Goetti et al. and Fujioka et al. showed that acceptable image quality and diagnostic performance required a low heart rate (respectively less than 63 and 75 bpm), which may be related to a standardized CTA protocol with a tube voltage of 100 kV, a relative low-pitch protocol or the absence of iterative reconstructions.9,10The results of the present study show that such limitations can be overcome with an ECG-gated high-pitch protocol using iterative reconstructions. Indeed, image quality of the ascending aorta was found to be excellent, allowing reliable diag- nosis. In addition, the vast majority of coronary artery segments (94%) were of diagnostic value in spite of a high heart rate and the absence ofb-blocker administration, corresponding to 60% of the patients. Furthermore, significantly more coronary segments were diagnostic with a low heart rate (65 bpm), but image quality remained diagnostic in 91% and 88% of the segments in patients with a high heart rate for reader 1 and 2, respectively. Moreover, in most the patients only one or two segments were non-diagnostic

(78% and 66% for reader 1 and 2, respectively). We believe that it is a satisfying compromise for both analysis of the aorta and cor- onary arteries. As stated previously mentioned, in patients with non-diagnostic images, a dedicated segmented coronary acquisi- tion should be considered. (seeFig. 1)

The absence of medication administration is clinically relevant, becauseb-blocker administration is sometimes contraindicated in the emergency context, for patients with acute cardiovascular disease and at risk of developing hemodynamic instability.

Furthermore the workflow is not affected by ECG positioning or drug administration. Because relevant clinical information can be obtained for the ascending aorta and coronary arteries, we recommend this protocol for aortic disease.

The use of a systolic window for high heart rate has been pro- posed by Sun et al.21and Goetti et al.22to improve the image quality of coronary arteries. Systolic imaging was not used in patients with fast heart rate as it induces a significant change in aortic diameter by comparison to diastolic imaging and as our referring physician were used to diastolic imaging. However, the benefit of systolic acquisitions for combined aortic and coronary CTA remains clearly to be investigated in furthermore studies.

Indeed, another important advantage of the present CT protocol is the use of iterative reconstruction. Iterative reconstruction al- gorithms are now widely used routinely for vascular imaging23and aim at reducing image noise while increasing CNR. The use of iterative reconstructions has already been studied with coronary CTA. It offers high image quality and can provide high diagnostic accuracy for the detection of coronary artery stenosis.24In addition, iterative reconstruction algorithms are a post-processing option available for reducing radiation dose at CT. Several studies have shown that iterative reconstructions allowed a 50% reduction in dose deposition, while preserving image quality and diagnostic accuracy of coronary CTA.7,25,26 Schuhbaeck et al. demonstrated that for a coronary-CT, the addition of high-pitch with raw data- based iterative reconstruction results in a furthermore decrease in dose, while providing sufficient image quality with an estimated effective dose <0.1 mSv.27In the present study, the acquisition protocol was optimized for CTA of the thoraco-abdominal aorta and not exclusively for the heart. Yet the effective dose was a mean of 3.9±1.5 mSv. This is interesting, especially when compared with currently reported mean radiation dose for the assessment of the aorta and the coronary arteries in a single acquisition (ranging from 7.5 to 18.42 mSv).9,28,29

CAD screening is essential in these patients suffering from aortic Table 5

Comparison between 24 Coronary-CT vs 24 coronary angiographies.

RCA LM LAD LCx Int. Total

Segment No 1 2 3 4 16 5 6 7 8 9 10 11 12 13 14 15 17

No of segments CT

24 24 21 16 10 24 24 24 22 21 12 24 16 17 13 7 9 308

No of segments angiography

24 24 22 21 18 24 24 24 22 22 18 24 21 22 19 15 10 354

Kappa 1.0

±0.0 1.0

±0.0 0.78

±0.2 0.44

±0.18 0.23

±0.15 1.0

±0.0 1.0

±0.0 1.0

±0.0 1.0

±0.0 0.33

±0.29 0.33

±0.16 1.0

±0.0 0.44

±0.18 0.36

±0.19 0.3

±0.17 0.25

±0.15 0.91

±0.08

No of stenosis CT 5 9 4 0 0 0 3 4 1 3 0 2 3 2 0 1 2 39

No of stenosis angiography

3 8 5 1 0 0 3 3 1 3 0 2 3 3 0 2 2 39

Kappa 0.71

±0.19 0.91

±0.09 0.86

±0.13 0.0

±0.0 1.0

±0.0 1.0

±0.0 1.0

±0.0 0.83

±0.16 1.0

±0.0 1.0

±0.0 1.0

±0.0 1.0

±0.0 1.0

±0.0 0.77

±0.21 1.0

±0.0 0.63

±0.33 1.0

±0.0 0.91

±0.06

Sensibility 1.0 1.0 0.8 0.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.5 1.0 0.9

Specificity 0.9 0.94 1.0 1.0 1.0 1.0 1.0 0.95 1.0 1.0 1.0 1.0 1.0 0.95 1.0 1.0 1.0 0.98

PPV 0.6 0.89 1.0 0.0 1.0 1.0 1.0 0.75 1.0 1.0 1.0 1.0 1.0 0.66 1.0 1.0 1.0 0.88

PNV 1.0 1.0 0.95 0.95 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.93 1.0 0.99

Accuracy 0.92 0.95 0.95 0.95 1.0 1.0 1.0 0.95 1.0 1.0 1.0 1.0 1.0 0.95 1.0 0.94 1.0 0.98

LAD: left anterior descending artery; LCx: left circumflex artery; LM: left main artery; RCA: right coronary artery.

Values are indicated as numbers (n/24).

(7)

disease and who are at high risk of developing CAD. Importantly, sensitivity and negative predictive value of coronary abnormalities are excellent, allowing exclusion of CAD on a normal CTA and also avoiding diagnostic coronary angiography. If CAD was diagnosed on the CTA, characterization of the coronary plaque was possible, as previously reported.30 Moreover, regarding recent publications, coronary calcifications would not be a contraindication to perform a coronary CT whatever the calcium scoring.31(seeFig. 2)

Furthermore, aortic CTA was useful for planning a coronary

angiography before a procedure such as TAVR, coronary treatment or coronary artery by-pass graft analysis. In our study, after the identification of previously unknown CAD, the management of the aortic disease of two asymptomatic patients was completely changed. Finally, there are 2 clinical implications of our study:first, coronary arteries should always be carefully analyzed and reported in gated aortic high-pitch CTA as a very high number of coronary segments are of diagnostic quality even at heart rate>65 bpm.

Coronary artery analysis is no longer restricted to specialized Fig. 1.Aortic-CTA of 70 year-old male and 65 year-old female with aortic dissection with 63 beats per minute (Fig. 1a/1b/1c/1d) and with 86 beats per minute (Fig. 1e/1f/1g/1h) on different Volume Rendering techniques and curve MultiPlanar reconstructions of the aorta (1a/b/e/f) and of coronary arteries (1c/d/g/h). For these 2 patients, the analysis of the whole aorta and coronary arteries could be possible: aortic dissection was clearly seen and coronary artery disease was depicted or excluded (arrows) despite the relatively high heart rate.

Fig. 2.68-year-old man with RCA stenosis due to a mixed plaque on different curve MPR reconstructions (a/b). Coronary angiography confirmed the significant stenosis (c) with an excellent result of the angioplasty (d).

A.-L. Hachulla et al. / Journal of Cardiovascular Computed Tomography 10 (2016) 407e413 412

(8)

cardiac radiologist but really needs to be mastered by every radi- ologist. Then, when a combined examination of aorta and coronary arteries is required, a high pitch CTA protocol with ECG gating of the entire aorta could be performedfirst. In case of motion artifacts, and when clinically required, a dedicated segmented acquisition targeted to heart could be performed.

Aside from its retrospective design, this study has several limi- tations. First, the smaller detector of the dual-source system covers afield of view of 60 cm2. Thus a portion of subcutaneous abdominal structures may be cropped, especially in obese patients. Never- theless, the analysis of central arteries has never been compro- mised, including the iliac and femoral arteries. Secondly, the diagnostic performance of coronary CAT was verified in only 24 patients with invasive coronary angiography. Coronary CTA has become a robust clinical tool for the diagnosis and exclusion of CAD.

Due to its high sensitivity and negative predictive value, only pa- tients with suspected CAD underwent coronary angiography.

Thirdly, because half the patients included underwent CTA for abdominal aneurism or before TAVR, this is responsible for a pre- dominantly elderly and male population, well correlated with the literature32but no different diagnostic accuracy of the coronary-CT or of the coronary angiography has been so far reported in the literature between female and male and therefore it should not affect the significance of our results. Finally, the amount of contrast media injected was not correlated to patient weight. Furthermore studies should address the amount of contrast media needed and aim at reducing its volume.

In conclusion, ECG-gated aortic CT with high-pitch acquisition yields an accurate exploration of aorta with limited dose deposi- tion. In addition, despite the lack ofb-blocker injection and rela- tively high heart rate, the quality of coronary arteries was diagnostic in 94% of the segments. Therefore, screening for coro- nary artery disease could be feasible in aortic examination.

Conflicts of interest None.

IRB statement

The local institutional review board approved the study.

Acknowledgements

Our thanks to Angela Frei for her help in proofreading this paper.

References

1. Ko SF, Hsieh MJ, Chen MC, et al. Effects of heart rate on motion artifacts of the aorta on non-ECG-assisted 0.5-sec thoracic MDCT. AJR Am J Roentgenol.

2005;184:1225e1230.

2. Woodard PK, White RD, Abbara S, et al. ACR Appropriateness Criteria chronic chest pain-low to intermediate probability of coronary artery disease.J Am Coll Radiol JACR. 2013;10:329e334.

3. Mammen L, White RD, Woodard PK, et al. ACR Appropriateness Criteria(R) on chest pain, suggestive of acute coronary syndrome.J Am Coll Radiol JACR.

2011;8:12e18.

4. Abdulla J, Abildstrom SZ, Gotzsche O, Christensen E, Kober L, Torp-Pedersen C.

64-multislice detector computed tomography coronary angiography as po- tential alternative to conventional coronary angiography: a systematic review and meta-analysis.Eur Heart J. 2007;28:3042e3050.

5. Budoff MJ, Dowe D, Jollis JG, et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial.J Am Coll Cardiol. 2008;52:1724e1732.

6. Yin WH, Lu B, Hou ZH, et al. Detection of coronary artery stenosis with sub- milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction.Eur Radiol. 2013;23:2927e2933.

7. Yin WH, Lu B, Li N, et al. Iterative reconstruction to preserve image quality and diagnostic accuracy at reduced radiation dose in coronary CT angiography: an intraindividual comparison.JACC Cardiovasc Imaging. 2013;6:1239e1249.

8. Scharf M, Bink R, May MS, et al. High-pitch thoracic CT with simultaneous assessment of coronary arteries: effect of heart rate and heart rate variability on image quality and diagnostic accuracy.JACC Cardiovasc Imaging. 2011;4:

602e609.

9. Fujioka C, Horiguchi J, Kiguchi M, Yamamoto H, Kitagawa T, Ito K. Survey of aorta and coronary arteries with prospective ECG-triggered 100-kV 64-MDCT angiography.AJR Am J Roentgenol. 2009;193:227e233.

10. Goetti R, Baumuller S, Feuchtner G, et al. High-pitch dual-source CT angiog- raphy of the thoracic and abdominal aorta: is simultaneous coronary artery assessment possible?AJR Am J Roentgenol. 2010;194:938e944.

11. Sun Z, Ng KH. Prospective versus retrospective ECG-gated multislice CT coro- nary angiography: a systematic review of radiation dose and diagnostic ac- curacy.Eur J Radiol. 2012;81:e94e100.

12. Wuest W, Anders K, Schuhbaeck A, et al. Dual source multidetector CT- angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.Eur Radiol. 2012;22:51e58.

13. Hoffmann U, Pena AJ, Cury RC, et al. Cardiac CT in emergency department patients with acute chest pain.Radiogr A Rev Publ Radiol Soc N Am Inc. 2006;26:

963e978. discussion 979e980.

14. Menzel HG, Harrison JD. Doses from radiation exposure.Ann ICRP. 2012;41:

12e23.

15. Tsai TT, Trimarchi S, Nienaber CA. Acute aortic dissection: perspectives from the International Registry of Acute Aortic Dissection (IRAD).Eur J Vasc Endovasc Surg off J Eur Soc Vasc Surg. 2009;37:149e159.

16. Beeres M, Schell B, Mastragelopoulos A, et al. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: initial experi- ence.Eur Radiol. 2012;22:129e137.

17. Bolen MA, Popovic ZB, Tandon N, Flamm SD, Schoenhagen P, Halliburton SS.

Image quality, contrast enhancement, and radiation dose of ECG-triggered high-pitch CT versus non-ECG-triggered standard-pitch CT of the thor- acoabdominal aorta.AJR Am J Roentgenol. 2012;198:931e938.

18. Liu Y, Xu J, Li J, et al. The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography.J Cardiothorac Surg.

2013;8:228.

19. Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system.Eur Radiol. 2006;16:256e268.

20. Stolzmann P, Leschka S, Scheffel H, et al. Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose.Radiology.

2008;249:71e80.

21. Sun K, Han RJ, Ma LJ, Wang LJ, Li LG, Chen JH. Prospectively electrocardiogram- gated high-pitch spiral acquisition mode dual-source CT coronary angiography in patients with high heart rates: comparison with retrospective electrocardiogram-gated spiral acquisition mode.Korean J Radiol. 2012;13:

684e693.

22. Goetti R, Feuchtner G, Stolzmann P, et al. High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates.Eur Radiol. 2010;20:

2565e2571.

23. Gosling O, Loader R, Venables P, et al. A comparison of radiation doses between state-of-the-art multislice CT coronary angiography with iterative recon- struction, multislice CT coronary angiography with standard filtered back- projection and invasive diagnostic coronary angiography. Heart. 2010;96:

922e926.

24. Achenbach S, Goroll T, Seltmann M, et al. Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography.JACC Cardiovasc Imaging. 2011;4:328e337.

25. Oda S, Utsunomiya D, Funama Y, et al. A knowledge-based iterative model reconstruction algorithm: can super-low-dose cardiac CT be applicable in clinical settings?Acad Radiol. 2014;21:104e110.

26. Ebersberger U, Tricarico F, Schoepf UJ, et al. CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction.Eur Radiol. 2013;23:125e132.

27. Schuhbaeck A, Achenbach S, Layritz C, et al. Image quality of ultra-low radia- tion exposure coronary CT angiography with an effective dose<0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction.Eur Radiol. 2013;23:597e606.

28. Li Y, Fan Z, Xu L, et al. Prospective ECG-gated 320-row CT angiography of the whole aorta and coronary arteries.Eur Radiol. 2012;22:2432e2440.

29. Willemink MJ, Meijs MF, Cramer MJ, et al. Coronary artery assessment on electrocardiogram-gated thoracoabdominal multidetector computed tomo- graphic angiography for aortic evaluation.J Comput Assist Tomogr. 2014;38:

185e189.

30. Saremi F, Achenbach S. Coronary plaque characterization using CT.AJR Am J Roentgenol. 2015;204:W249eW260.

31. den Dekker MA, de Smet K, de Bock GH, Tio RA, Oudkerk M, Vliegenthart R.

Diagnostic performance of coronary CT angiography for stenosis detection according to calcium score: systematic review and meta-analysis.Eur Radiol.

2012;22:2688e2698.

32. George J, Rapsomaniki E, Pujades-Rodriguez M, et al. How does cardiovascular diseasefirst present in women and men? incidence of 12 cardiovascular dis- eases in a contemporary cohort of 1 937 360 people.Circulation. 2015;132:

1320e1328.

Références

Documents relatifs

Title Page Abstract Introduction Conclusions References Tables Figures ◭ ◮ ◭ ◮ Back Close Full Screen / Esc. Printer-friendly Version

Left column: 1914 to 1964 variation in Earth-surface radial mag- netic field, for the geomagnetic field model COV-OBS (top), the ensemble average of the assimilation started in

But 10 compare the dynamics which contributed 10 the Holocaust with those fuelling the present nuclear threat is 10 overlook the unique horror of each of those two

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des

Ilseraitégalementutiledebénéficierdesrésultatsd’une étude de prévention secondaire au long cours, comparant l’efficacité d’une faible dose d’edoxaban

Professor Zolt- vany's rational approach to Du- plessis and the formation of L'U- nion Nationale gives a needed historical perspective to the &#34;Quiet Revolution.&#34;

Mentionnons entre autres: la mise en place de parcours de formation capables de susciter l’intérêt de celles et ceux que la formation traditionnelle éloigne de

Variance components and Q SC values for eight phenotypic traits and seven phenotypic plasticity indices calculated for 10 populations in each of the native