• Aucun résultat trouvé

Capillary Electrophoresis-Ultraviolet-Mass Spectrometry (CE-UV-MS) for the Simultaneous Determination and Quantification of Insulin Formulations

N/A
N/A
Protected

Academic year: 2022

Partager "Capillary Electrophoresis-Ultraviolet-Mass Spectrometry (CE-UV-MS) for the Simultaneous Determination and Quantification of Insulin Formulations"

Copied!
8
0
0

Texte intégral

(1)

Book Chapter

Reference

Capillary Electrophoresis-Ultraviolet-Mass Spectrometry (CE-UV-MS) for the Simultaneous Determination and Quantification of Insulin

Formulations

SCHAPPLER, Julie, RUDAZ, Serge

Abstract

This chapter describes a CE-UV-MS method for the identification and quantification of insulin in pharmaceutical formulations in a single run. The CE conditions are optimized to avoid the adsorption of the protein onto the capillary wall. Particular attention is paid regarding the choice of the internal standard. A strategy based on multiple injections is applied to correct both ionization and injection variabilities. The methodoligy is validated according to internal guidelines and the obtained accuracy profile demonstrates the ability of the CE-UV-MS method to quantify insulin in pharmaceutical formulations within a 15% acceptance range.

This strategy can be implemented in the field of quality control, as well as in the detection of counterfeits.

SCHAPPLER, Julie, RUDAZ, Serge. Capillary Electrophoresis-Ultraviolet-Mass Spectrometry (CE-UV-MS) for the Simultaneous Determination and Quantification of Insulin Formulations. In:

Nguyet Thuy Tran and Myriam Taverna. Capillary Electrophoresis of Proteins and Peptides - Methods and Protocols . France : Humana Press, 2016.

Available at:

http://archive-ouverte.unige.ch/unige:92042

Disclaimer: layout of this document may differ from the published version.

1 / 1

(2)
(3)
(4)
(5)
(6)
(7)
(8)

Références

Documents relatifs

In this section, we discuss the enumeration of partial injections on [[1, n]], the probability for an A-tuple of such partial injections to yield a labeled connected A-graph,

Purification by flash chromatography (hexane:ether =.. The 1H NMR spectrum matched the published spectrum.. Absolute Configuration Assignment for Table 2, entry 3:

of submitted results for Case 1 report a total duration estimate which is different by less than 1% compared to the true duration. Some participants arrived at the exact

L’autonomie  qui  a  donné  de  nouveaux  droits  aux  universités  suscite  évidemment  de 

In Maspero-Robert [31], the authors study linear Schr¨ odinger operators, obtain global well- posedness results and prove very precise polynomial bounds on the possible growth

of liquid chromatography combined with drift tube ion mobility-mass spectrometry. D., Peak capacity in

We chose to increase analysis time to separate all major phenolic compounds present in apple juice, especially to avoid, as much as possible, co-elutions that may affect

As was the case with the previous provision, the possibility to deprive somebody of its nationality was limited in time. It could only take place provided the person concerned