• Aucun résultat trouvé

Accuracy of Cockcroft&Gault and CKD-EPI equations to estimate glomerular filtration rate in obese population

N/A
N/A
Protected

Academic year: 2021

Partager "Accuracy of Cockcroft&Gault and CKD-EPI equations to estimate glomerular filtration rate in obese population"

Copied!
1
0
0

Texte intégral

(1)

Abstract N°1

Accuracy of Cockcroft&Gault and CKD-EPI equations to estimate glomerular filtration rate in obese population.

Antoine Bouquegneau1, Emmanuelle Vidal-Petiot2, François Vrtovsnik2, Etienne Cavalier3, Jean-Marie

Krzesinski1, Martin Flamant2, Pierre Delanaye1

1 Department of Nephrology-Dialysis-Transplantation, University of Liège, CHU Sart Tilman,

Liège, Belgium

2 Department of Renal Physiology, Hôpital Bichat, AP-HP and Denis Diderot University,

Paris, France

3 Department of Clinical Chemistry, University of Liège, CHU Sart Tilman, Liège, Belgium 4 Department of Diabetology, University of Liège, CHU Sart Tilman, Liège, Belgium

Introduction:

The prevalence of obesity is dramatically rising worldwide. When drug dosing is considered, KDIGO recommends using estimated glomerular filtration rate (eGFR), which is not adjusted to the body surface area (BSA). We have tested the performances of two creatinine-based equations: Chronic Kidney Disease

Epidemiology Collaboration (CKD-EPI) “de-indexed” by BSA, and Cockcroft&Gault (CG) equation (non-indexed by BSA) with actual body weight or adjusted ideal body weight (AIBW). We test the performance of these equations by comparing them with measured GFR (mGFR) also expressed in mL/min.

Methods:

Patients with body mass index (BMI) higher than 30 kg/m² were included. The reference method for GFR measurement was plasma clearance of 51Cr-EDTA. We have “de-indexed” CKD-EPI, which is a BSA-adjusted

value, by multiplying eGFR by each individual’s body surface area and by dividing this intermediate result by 1.73 m2 (CKD-EPI

deindexed). We calculated bias (defined as the mean difference between estimated and measured

GFR), precision (defined as the SD around the bias) and accuracy 30% (defined as the percentage of estimations within ± 30% of measured GFR).

Results:

The population included 366 patients (185 women) from two different areas. Mean age was 55 ± 14 years and mean BMI was 36 ± 7 kg/m2. Mean mGFR was 71 ± 35 mL/min. In the global population, bias of CG and

CGAIBW was + 25 ± 39.8 mL/min and + 2.6 ± 21.7 mL/min, respectively. Accuracy 30% was 57% and 78%,

respectively(p<0.05). For the CKD-EPIdeindexed equation, the bias was + 6.2 ± 19.7mL/min and the accuracy 30%

was 76%. Conclusion:

CG is actually the equation used for drug dosing adaptation. Its accuracy to estimate GFR is however not optimal in obese patients, as expected by the bias induced by the actual body weight in the equation. Using adjusted ideal body weight in CG avoids this inadequacy and significantly improves the performance of the CG. We

demonstrated that CKD-EPIdeindexed had globally the same performance as the CGAIBW equation to estimate

non-indexed mGFR.

De-indexed mGFR

(mL/min) CG CGAIBW CKD-EPIdeindexed

Bias 25.0 2.6 6.2

Precision 39.8 21.7 19.7

Accuracy 30% 57 78 76

Références

Documents relatifs

Similarity aggregation method (Marcotorchino, 1981) Input: n individuals described by p qualitative variables,.. or: a symmetric square array of

Cette méthode directe repose sur le point de cours suivant, appelé parfois lemme d’Euclide (à ne pas confondre avec le lemme d’Euclide portant sur les nombres premiers).. Dans

Compared with sitagliptin 100 mg, all clinical trials performed with empagliflozin or canagliflozin (no such comparative trial available with dapagliflozin) showed a similar

the ability to recall memoranda independently of their serial position within a list, is typically enhanced by long-term memory (LTM) knowledge.. In contrast, the interactions

Brlek, Enumeration of factors in the Thue-Morse word, DAM’89.. Varricchio, On the factors of the Thue-Morse word on three

t.20(1866-1867): http://www.biodiversitylibrary.org/item/194576 Article/Chapter Title: Rectification et addition à la note sur un problème d'analyse indéterminée. Author(s):

[r]

Ces systèmes, jusque là non ou très peu exploités dans le secteur, visent non seulement à faciliter l’incorporation et la stabilisation des composés