• Aucun résultat trouvé

Smart co-phasing system for segmented mirror telescopes

N/A
N/A
Protected

Academic year: 2021

Partager "Smart co-phasing system for segmented mirror telescopes"

Copied!
1
0
0

Texte intégral

(1)

Smart co-phasing system for segmented mirror telescopes

SPIE: 9906-207

Juan F Simar*

a

, Yvan Stockman

a

, Jean Surdej

b

a

Centre Spatial de Liège, LIEGE Science Park, Avenue du Pré-Aily, 4031 Angleur, Belgium;

b

Institut d'Astrophysique et de Géophysique, Université de Liège, Allée du 6 Août 19c, 4000 Liège, Belgium

METHODS

INTRODUCTION

RESULTS

1. Applied Optics, Vol. 54, Issue 5, pp. 1118-1123 (2015), Single

wavelength coarse phasing in segmented telescopes

2. SPIE, vol. 7731, p 165 (2010), First steps of the development of a piston

sensor for large aperture space telescopes

3. Proc. SPIE 4003, Optical Design, Materials, Fabrication, and

Maintenance, 188 (July 20, 2000), Phasing the primary mirror segments of

the Keck telescopes: a comparison of different techniques

CONCLUSIONS

REFERENCES

*[email protected]; phone +32 (0)4 382.46.00; fax +32 (0)4 367.56.13; www.csl.ulg.ac.be

One of the main challenges in space observations is to observe always fainter and more compact

objects. This can be achieved by increasing the telescope diameters. So, increasing the primary

mirror diameters of the telescopes is the challenge solution but it is technically impossible to

manufacture monolithic mirrors larger than 10m in diameter. The use of segmented mirrors thus

becomes mandatory. This paper describes the results of a light co-phasing setup mounted in laboratory. This setup is able to correct a piston from 200μm to 15 nm based on coarse (200μm to 300nm) and fine (300nm to 15nm) measurement

methods. Both measurements are then chained in a feedback system in order to completely co-phase

and keep the segments aligned.

A very compact and light system has been presented. This system can be adapted to any type of space or ground segmented mirror.

The system speed and precision could still be improved using high speed camera and optimized hardware.

Compared with Keck, this system has advantages but

additional assessment must be performed to validate it for the case of a real segmented mirror.

Coarse measurement implementation

Fig. 1 Optical setup implementation

Table 1. Results of piston measurements after the co-phasing is finished. Average of 50 measurements (Left column), standard

deviation (Central column), HP55191A measurement (Right column, this measurement leads to a Standard Deviation of 10nm).

Optical Setup

The following optical setup has been implemented in order to verify the methods.

Fig. 2 PSF (left) and MTF (right) used for the coarse measurement

Fine measurement implementation

It was implemented in a feedback system for automated piston correction.

The PSF is measured to calculate the MTF (Modulation Transfer Function).

The peak heights of the MTF are measured so the distance (200µm to 300nm) between segments can be estimated.

The heights and inclinations of the PTF peaks are measured so the fine piston (300nm to 15nm) and tip/tilt between the segments can be found.

With the same PSF, the PTF (Phase Transfer Function) is calculated.

Fig. 3 PSF (left) and PTF (right) used for the fine measurement

Références

Documents relatifs

Monge-Kantorovich mass transport problem, Large deviations of empirical measures, Γ-convergence, Doubly indexed large deviation principle, relative

However, the model also shows that inhibitory cells, spiking activity and deep layers are non-negligible and should be taken into account in the com- putation of the optical

We prove an expo- nential deviation inequality, which leads to rate optimal upper bounds on all the moments of the missing volume of the convex hull, uniformly over all convex bodies

For a typical neutrino beam, which provides neutrinos in the energy range 2–8 GeV, the event rate dependence from baseline is shown in Figure 11.. An optimal separation between NH

Discharge tube (1), Thermostatic bath (2), only the lowest mode is acctually excised with Power supply for magnetic bench (3), Coaxial laun- launchers located outside the

Key words: Cluster analysis, clustering functions, clustering algorithm, categorical and real continuous data, experimental protocol..

We propose a solution to estimate the first two moments of the end-to-end delay experienced by the packets of a flow in a wired network based only on delay measurements

Biophysical cortical column model for optical signal analysis Sandrine Chemla* 1 , Frederic Chavane 2 , Thierry Vieville 1 and.. Pierre