Articles de congrès national avec comité de lecture : Congrès de la Société de Biomécanique : Toulouse 2012
Bernard J., Hayot C., Decatoire A., Lacouture P., ‘Comparison of motor strategy between confirmed and professional cyclists during an incremental maximal test’. Computer Methods in Biomechanics and Biomedical Engineering. (2012), 15: 220-223.
Congrès de la Société de Biomécanique : Marseille 2013
Hayot C., Domalain M., Bernard J., Decatoire A., Lacouture P., ‘Muscle force strategies in relation to saddle setback management in cycling’. Computer Methods in Biomechanics and Biomedical Engineering. (2013), 16: 106-108.
Articles de congrès international avec comité de lecture:
Congrès International Sports Engineering Association (ISEA): LongBeach 2012
Hayot C., Decatoire A., Bernard J., Monnet T., Lacouture P., ‘Effects of ‘posture length’ on joint power in cycling’. Procedia Engineering. (2012), 32: 212-217.
Congrès International Society of Biomechanics in Sports (ISBs): Poitiers 2015
Bernard J., Decatoire A., Lacouture P., ‘Comparison of two pedaling sensors, I-
Crankset and SRM, against a standard reference sensor’.
Publication affichée congrès national avec comité de lecture: Congrès de la Société de Biomécanique : Valencienne 2014
Bernard J., Decatoire A., Lacouture P., ‘Comparison of 2D vs 3D joint
Bibliographie
Abbiss [2009] Abbiss C.R., Quod M.J., Levin G., Martin D.T., Laursen P.B., ‘Accuracy of the Velotron ergometer and SRM power metre’. International Journal of Sports Medicine. (2009) ; 30, 107-112.
Alvarez [1996] Alvarez G., Vinyolas J., ‘A new bicycle pedal design for on-road measurments of cycling forces’. Journal of applied Biomechanics.
(1996); 12, 130-142.
Balmer [2000a] Balmer J., Davidson R.C., Colemen D.A., Bird S.R., ‘The validity of
power output recorded during exercise performance tests using a kingcycle air-braked cycle ergometer when compared with an SRM
powermeter’. International Journal of Sports Medicine. (2000);21, 195- 199.
Balmer [2000b] Balmer J., Davidson R.C., Bird S.R., ‘Reliability of an air- braked ergometer to record peak power during a maximal cycling test’. Medicine & Science in Sports & Exercise. (2000) ; 32, 1790-1793.
Bertucci [2003] Bertucci W., ‘Etude de l’interface homme/machine en cyclisme à partir de l’analyse biomécanique du pédalage et de la réalisation d’un ergomètre’. Thèse de l’université de Franche-Comté. (2003).
Bertucci [2005] Bertucci W., Grappe F., Girard A., Betik A., Rouillon J.D., ‘Effects
on the crank torque profile when changing pedalling cadence in level
ground and uphill road cycling’. Journal of Biomechanics. (2005); 38, 1003-1010.
Bertucci [2005b] Bertucci W., Duc S., Villerius V., Pernin J.N., Grappe F., ‘Validity
and reliability of the PowerTap cycling powermeter when compared
with the SRM device’. International Journal of Sports Medicine.
Bertucci [2011] Bertucci W., Grappe F., Crequy S., ‘Original characteristics of a new cycle ergometer’, Sports Engineering. (2011); 13, 171-179.
Bini [2008] Bin R.R., Diefenthaeler F., Mota C.B., ‘Fatigue effects on the coordinative pattern during: kinetics and kinematics evaluation‘. Journal of Electromyography and kinesiology. (2008); 20, 1: 102-107.
Bini [2009] Bini R.R., Diefenthaeler F., ‘Mechanical work and coordinative pattern of cycling: a literature review‘. Kinesiology. (2009); 41, 1:25-39.
Bini [2011] Bini, R.R., Hume P.A., Cervini A., ‘A comparison of cycling SRM
crank and strain gauge instrumented pedal measures of peak torque,
crank angle at peak torque and power output’. Procedia Engineering.
(2011); 13, 56-61.
Bini [2012] Bini R.R., Hume P.A., Lanferdini F.J., Vaz M.A., ‘Effects of moving
forward and backward on the saddle on knee joint forces during
cycling’. Physical Therapy in Sport. (2012); 14, 1: 23-27.
Bini [2012a] Bini, R.R., ‘Patellofemoral and tibiofemoral forces in cyclists and triathletes: effects of saddle height’. Journal of Science and Cycling.
(2012); 1, 1: 9-14.
Bini [2013] Bini R.R., Hume P.A., ‘Between-day reliability of pedal forces for
cyclists during an incremental cycling test to exhaustion’. Isokinetics and Exercise Science. (2013); 21, 203-209.
Bini [2013a] Bini R.R., Hume P., Croft J., Kilding A., ‘Pedal force effectiveness in cycling: a review of constraints and training effects’. Journal of Science and Cycling. (2013); 2, 1: 11-24.
Bini [2014] Bini R., Carpes F.P., ‘Biomechanics of Cycling’. Edition Springer.
(2014).
Bland [1986] Bland J.M., Altman D.G., ‚Statistical methods for assessing agreement
between 2 methods of clinical measurement’. Lancet. (1986); 1,307-
310.
Boucher [2005] Boucher M., ‘Limite et précision d’une analyse mécanique de la performance sur ergocycle instrumenté’. Thèse de l’université de Poitiers. (2005).
Boyd [1996] Boyd T., Hull M.L., Wootten D., ‘An improved accuracy six-load component pedal dynamometer for cycling’. Journal of Biomechanics.
(1996); 24, 8: 1105-1110.
Broker [1990] Broker J.P., Gregor R.J., ‘A dual piezoelectric element force pedal for kinetic analysis of cycling’. International Journal of Sport Biomechanics. (1990); 6, 394-403.
Coyle [1991] Coyle E.F., Feltner M.E., Kautz S.A., Hamilton M.T., Montain S.J., Baylor A.M., Abraham L.D., Petrek G.W., ‘Physiological and
biomechanical factors associated with elite endurance cycling
performance’. Medicine and Science in Sports and Exercise. (1991); 23, 1: 93-107.
Davis [1981] Davis R.R., Hull M.L., ‘Measurement of pedal loading in bicycling: II. Analysis and results’. Journal of Biomechanics. (1981); 14: 12, 857- 872.
Debraux [2010] Debraux P., ‘Etude des déterminants de la performance en cyclisme: puissance musculaire et aérodynamisme application en BMX’. Thèse de
l’université de Reims Champagne-Ardenne. (2010).
De Leva [1995] De Leva P., ‘Adjustments to Zatsiorsky-Seluyanov’s segment inertia
parameters’. Journal of Biomechanics. (1995); 29, 9, 1223-1230.
Dorel [2008] Dorel S., Couturier A., Hug F., ‘Intra-session repeatability of lower limb muscles activation pattern during pedaling’. Journal of Electromyography and Kinesiology. (2008); 18, 857-865.
Dorel [2009] Dorel S., Couturier A., Hug F., ‘Influence of different racing positions on mechanical and electromyographic patterns during pedaling’. Scandinavian Journal of Medicine and Science in Sports and Exercise.
(2009); 19, 1: 44-54.
Duc [2005] Duc S., Betik A.C., Grappe F., ’EMG activity does not change during a time trial in competitive cyclists’. International Journal of Sports Medicine. (2005); 26: 145-150.
Earnest [2005] Earnest C.P., Wharton R.P., Church T.S., Lucia A., ‘Reliability of
the Lode Excalibur sport ergometer and application to computrainer
electromagnetically braked cycling training device’. The Journal of Strength & Conditioning Research. (2005); 19: 344-348.
Elmer [2011] Elmer S., Barratt P.R., Korff T., Martin C.J., ‘Joint-specific power production during submaximal and maximal cycling’. Medicine & Science in Sports & Exercise. (2011); 43, 10: 1940-1947.
Ettama [2009] Ettama G., Loras H., Leirdal S., ‘The effects of cycling cadence on the
phases of joint power crank power, force and force effectiveness.’
Journal ofElectromyography and Kinesiology. (2009); 19, 94-101.
Gardner [2004] Gardner A.S., Stephens S., Martin D.T., Lawton E., Lee H., Jenkins D., ‘Accuracy of SRM and PowerTap power monitoring systems for
bicycling’. Medicine & Science in Sports & Exercise. (2004) ; 36, 7 :
1252-1258.
Ferrari [2010] Ferrari A., Cutti A.G., Capello A., ‘A new formulation of the
coefficient of multiple correlations to assess the similarity of waveforms
measured synchronously by different motion analysis protocols’. Gait&
Posture. (2010); 31:4,540-542.
Grappe [2000] Grappe F., ‘Etude des variables de la performance en sport : Application au cyclisme’. Candidature à une habilitation à diriger des recherches. (2000).
Grappe [2009] Grappe F., ‘ Cyclisme et optimisation de la performance’. Edition De Boeck Université, seconde édition. (2009)
Gregor [1994] Gregor R., Wheeler J., ‘Biomechanical factors associated with shoe/pedal interfaces, implication for injury’. Sports Medicine. (1994); 17:2, 117-131.
Hintzy [1999] Hintzy F., Belli A., Grappe F., Rouillon J.D., ‘Optimal pedalling
velocity charcteristics during maximal and submaximal cycling in
humans’. European Journal of Applied Physiology. (1999); 79, 426- 432.
Hopker [2010] Hopker J., Myers S., Jobson S.A., Bruce W, Passfield L., ‘Validity and reliability of the Wattbike Cycle ergometer’. International Journal of Sports Medicine. (2012); 31, 1-6.
Hoshikawa [2007] Hoshikawa H., Takahashi K., Ohashi K., Tamaki K., ‘Contribution
of the ankle, knee and hip joints to mechanical energy in cycling’.
Huang [2013] Huang L., Liu Y., Wei S., Li L., Fu W., Sun Y., Feng Y., ‘Segment-
interaction and relevance to the control of movement during sprinting’.
Journal of Biomechanics. (2013); 46, 2018-2023.
Hull [1981] Hull M.L., Davis R.R., ‘Measurement of pedal loading in bicycling: I. Instrumentation’. Journal of Biomechanics. (1981); 14: 12, 843-856.
Jones [1998] Jones S.M., Passfield L., ‘The dynamic calibration of bicycle power measuring cranks’. The Engineering of Sport. (1998); 265-275.
Kautz [1991] Kautz S.A., Feltner M.E., Coyle E.F., Baylor A.M., ‘The pedaling
technique of elite endurance cyclists: changes with increasing workload
at constant cadence’. International journal of sport biomechanics.
(1991); 7, 29-53.
Kautz [1993] Kautz S.A., Hull M.L., ‘A theoretical basis for interpreting the force applied to the pedal in cycling’. Journal of Biomechanics. (1993); 26, 2: 155-165.
Kautz [2002] Kautz S.A., Neptune R.R., ‘Biomechanical determinants of pedaling energetics: internal and external work are not independent’. Exercise and Sport Sciences Reviews. (2002) ; 30,4 : 159-165.
Korff [2007] Korff T., Romer L.M., Mayhew I., Martin J.C., ‘Effect of pedaling technique on mechanical effectiveness and efficiency in cyclists’. Medicine and Science in Sports and Exercise. (2007); 39: 6, 991-995.
Lawton [1999] Lawton E.W., Martin D.T., Lee H., ‘Validation of SRM power cranks using dynamic calibration’. Fifth IOC World Congress; Oct 31- Nov 5; Syndey. Sydney: International Olympic Committee. (1999).
Lepers [2004] Lepers R., Millet G, Maffiuletti N., ‘Etiologie et cinétique d’apparition de la fatigue neuromusculaire lors d’exercices prolongés de cyclisme’. Science et Motricité. (2004); 2, 52, 83-107.
Lloyd [2003] Lloyd D.G., Besier T.F., ‘An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo’. Journal of Biomechanics. (2003); 36, 765-776.
Louvet [2007] Louvet S., ‘Analyse couplée de paramètres mécaniques et physiologiques au cours de tests d’effort de longue durée sur ergocycle instrumenté’. Thèse de l’université de Poitiers. (2007).
Lucia [2001] Lucia A., Hoyos J., Chicharro J.L., ‘Preferred pedaling cadence in
professional cycling’. Medicine & Science in Sports & Exercise.
(2001) ; 33, 8 : 1361-1366.
MacIntosh [2001] MacIntosh B.R., Bryan S.N., Rishaug P., Norris S.R., ‘Evaluation of
the Monark Wingate ergometer by direct measurement of resistance and
Velocity’. Canadian Journal of Applied Physiology. (2001) ; 26 : 543 – 558.
Martin [2009] Martin J.C., Brown N.A.T., ‘Joint-specific power production and fatigue during maximal cycling’. Journal of Biomechanics. (2009); 42; 474-479.
Millet [2003] Millet G.P., Tronche C., Fuster N., Bentley D.J., Candau R., ‘Validity and reliability of PolarS710 mobile cycling powermeter’. International Journal of Sports Medicine. (2003); 24: 156-161.
Mornieux [2006] Mornieux G., Zameziati K., Mutter E., Bonnefoy R., Belli A., ‘A
cycle ergometer mounted on a standard force platform for three-
dimensional pedal forces measurement during cycling’. Journal of Biomechanics. (2006); 39, 1296-1303.
Nabinger [2002] Nabinger E., Iturrioz I., Zaro M.A., ‘Development of a triaxial force
platform for the measurement of force at a bicycle pedal’. International
Symposium of Biomechanics in Sports. (2002); 290-293.
Neptune [1997] Neptune R.R., Kautz S.A., Hull M.L., ‘The effect of pedaling rate on coordination in cycling’. Journal of Biomechanics. (1997); 30, 1051- 1058.
Neptune [1999] Neptune R.R., Herzog W., ‘The association between negative muscle work and pedaling rate’. Journal of Biomechanics. (1999); 32, 1021- 1026.
Neptune [2000] Neptune R.R., Kautz S.A., Zajac F.E., ‘Muscle contributions to
specific biomechanical functions do not change in forward versus
backward pedaling’. Journal of Biomechanics. (2000); 33, 155-164.
Padilla [1996] Padilla S., Mujika I., Cnesta G., Polo J.M., Chatard J.C., ‘Validity of
a velodrome test for competitive road cyclists’. European Journal of
Palmer [1996] Palmer G.S., Dennis S.C., Noakes T.D., Hawley J.A., ‘Assessment of
the reproducibility of performance testing on an air-braked cycle
ergometer’. International Journal of Sports Medicine. (1996) ; 17 : 293– 298.
Patterson [1990] Patterson R.P., Moreno M.L., ‘Bicycle pedaling forces as a function of pedaling rate and power output’. Medicine and Science in Sport and Exercise. (1990); 22, 512-516.
Paton [2001] Paton C.D., Hopkins W.G., ‘Tests of cycling performance’. Sports Medicine. (2001); 31, 7: 489-496.
Paton [2006] Paton C.D., Hopkins W.G., ‘Ergometer error and biological variation in power output in a performance test with three cycle ergometers’. International Journal of Sports Medicine. (2006); 27: 444–447.
Perrey [2003] Perrey S., Grappe F., Girard A., Bringard A., Groslambert A., Bertucci W., Rouillon J.D., ‘Physiological and metabolic responses of
triathletes to a simulated 30-min time-trial in cycling at self-selected
intensity’. International Journal of Sports Medicine. (2003); 24; 138- 143.
Peveler [2011] Peveler W.W., Green J.M., ‘Effects of saddle height on economy and
anaerobic power in well-trained cyclists’. Journal of Strength and
Conditioning Research. (2011); 25, 3: 629-633.
Poirier [2009] Poirier E., ‘Influence de paramètre biomécaniques et
électrophysiologiques sur la technique de propulsion: transition de la
posture classique vers la posture danseuse chez le cycliste’. Thèse de
l’université de Toulouse. (2009).
Reiser [2000] Reiser M., Meyer T., Kindermann W., Daugs R., ‘Transferability of workload measurements between three different types of ergometer’. European Journal of Applied Physiology. (2000); 82, 245-249.
Reiser [2003] Reiser R.F., Perterson M.L., Broker J.P., ‘Instrumented bicycle pedals for dynamic measurement of propulsive cycling loads’. Sports Engineering. (2003); 6, 41-48.
Riquet [2001] Riquet A., ‘Contribution à l’évaluation de l’énergie mécanique
dépensée par un athlète, lors d’exercices intenses et de courte durée sur
Rocha [2006] Rocha E., Bonezi D., Molenda D., Cantergi D., Candotti C., Loss J., ‘Place of the force and emg peak in different cadences in the cycling’. Journal of Biomechanics. (2006); 39, 1: 193.
Rossato [2008] Rossato M., Bini R.R., Carpes F.P., Diefenthaeler F., Moro A.R.P., ‘Cadence and workload effects on pedaling technique of well-trained cyclists’. International Journal of Sports Medicine. (2008); 29: 746-752.
Ruby [1993] Ruby P., Hull M.L., ‘Response of intersegmental knee loads to foot/pedal platform degrees of freedom in cycling’. Journal of Biomechanics. (1993); 26, 11: 1327-1340.
Sanderson [1991] Sanderson D.J., ‘The influence of cadence and power output on the
biomechanics of force application during steady-rate cycling in
competitive and recreational cyclists’. Journal of Sports Sciences.
(1991); 9, 191-203.
Sanderson [2003] Sanderson D.J., Black A., ‘The effect of prolonged cycling on pedal forces’. Journal of Sports Sciences. (2003); 21: 191-199.
Sarre [2004] Sarre G., ‘Caractérisation du pattern mécanique et neuromusculaire du
pédalage en cyclisme: effets de la cadence et de la fatigue au cours de
l’exercice prolongé’. Thèse de l’université de Bourgogne. (2004).
Sassi [2009] Sassi A., Rampinini E., Martin D.T., Morelli A., ‘Effects of gradient
and speed on freely chosen cadence : the key role of crank inertial load’.
Journal of Biomechanics. (2009); 42, 171-177.
Soden [1979] Soden P.D., Adeyefa B.A., ‘Forces applied to bicycle during normal cycling’. Journal of Biomechanics. (1979); 12: 527-541.
Stapelfeldt [2007] Stapelfeldt B., Mornieux G., Oberheim R., Belli A., Gollhoer A., ‘Development and evaluation of a new bicycle instruments for measurements of pedal forces and power output in cycling’. International Journal of Sports Medicine. (2007);28, 326-332.
Stepniewski [2014] Stepniewski A.A., Grudzinshi J., ‘The analysis of pedaling techniques with platform pedals’. International Journal of Applied Mechanics and Engineering. (2014); 19, 3: 633-642.
Umberto [2012] Umberto E., Denoth J., ‘Power-cadence relationship in endurance cycling’. European Journal of Applied Physiology.(2012) ; 112, 1 : 365- 375.
Umberger [2001] Umberger B.R., Martin P.E., ‘Testing the planar assumption during ergometer cycling’. Journal of Applied Biomechanics. (2001) ; 17, 55- 62.
VanPraagh [1988] Van Praagh E., ‘Etude sur ergocycle des métabolismes anaérobie et aérobie chez l’enfant (filles et garçons): essai de validation de tests de terrain’. Thèse de l’université de Poitiers. (1988).
Vergara [2014] Vergara C., ‘Pedaling torque sensor device for each cyclist’s leg and power meter apparatus’. United States Patent Application Publication.
(2014).
Wu [1995] Wu G., Cavanagh P.R., ‘ISB recommendations for standardization in the reporting of kinematic data’. Journal of Biomechanics. (1995); 28:
10, 1257–1261.
Wu [2002] Wu G., Siegle S., Allard P., Kirtley C., Leardini A., Rosenbaum D.,
Whittle M., D’Lima D.D., Cristofolini L., Wittle H., Schmid O.,