Positron emission tomography-computed tomography scan helps decision making in cardiac surgery

N/A
N/A
Protected

Academic year: 2021

Partager "Positron emission tomography-computed tomography scan helps decision making in cardiac surgery"

Copied!
1
0
0

Texte intégral

(1)

Positron emission tomography

–computed tomography

scan helps decision making in cardiac surgery

Sanjay Cherian

a

, René Nkoulou

b

, Afksendiyos Kalangos

a

and Mustafa Cikirikcioglu

a,

*

a Division of Cardiovascular Surgery, Medical Faculty, University Hospital of Geneva, Geneva, Switzerland b Division of Nuclear Medicine, Medical Faculty, University Hospital of Geneva, Geneva, Switzerland

* Corresponding author. Division of Cardiovascular Surgery, University Hospital of Geneva, Rue Gabrielle Perret-Gentil 4, Geneva, Switzerland. Tel: +41-22-3727663; fax: +41-22-3727634; e-mail: [email protected] (M. Cikirikcioglu).

Received 29 July 2012; accepted 8 August 2012

Keywords:

PET-CT

• Cardiac intervention

A 64-year old male who underwent a mechanical valve Bentall

pro-cedure at another institution presented 1 year postoperatively with

fever and dyspnoea. Laboratory investigations revealed

Candida

albicans infection with a periprosthetic collection. Confusion as to

whether the collection was infective endocarditis, a periprosthetic

transudate or a mass of haemostatic plugs used intraoperatively

was clari

fied by combined positron emission tomography–

computed tomography (PET

–CT scans; Fig.

1

).

Figure 1:Contrast CT scans (left panels) of the aortic root in axial (A), two-chamber (B) and three-chamber (C) views showing a collection surrounding the aortic walls (black arrows). Associated hypermetabolic uptake (white arrows) in 18-F-flouro-deoxyglucose (FDG) scans (right panels) was highly suggestive of an infectious process. The patient made an uneventful postoperative recovery following a replacement of the prosthesis with an aortic homograft. This case presentation rein-forces the role of the PET–CT scan as an important diagnostic tool in cases of difficult decision making in cardiac surgery.

© The Author 2012. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

European Journal of Cardio-Thoracic Surgery 43 (2013) 650

IMAGES IN CARDIO-THORACIC SURGERY

Figure

Figure 1: Contrast CT scans (left panels) of the aortic root in axial (A), two-chamber (B) and three-chamber (C) views showing a collection surrounding the aortic walls (black arrows)

Références

Documents relatifs

Quantitative Molecular Positron Emission Tomography Imaging Using Advanced Deep Learning Techniques.. ZAIDI, Habib, EL

Ultra-low-dose hybrid single photon emission computed tomography and coronary computed tomography angiography: a comprehensive and non- invasive diagnostic workup of suspected

Low-dose computed tomography coronary angiography and myocardial perfusion imaging: cardiac hybrid imaging below 3mSv..

Accordingly, imaging of apoptosis by means of whole body positron emission tomography, allowing for repetitive non- invasive in vivo detection of the site and the extent

Cardiac Func- tion Estimation Using Multislice Computed Tomography: A Comparison to Speckle Tracking Imaging.. Computers in Cardiology, Sep 2009, Park City, UT,

Aileen Mcgonigal, Marie Arthuis, Jean-Arthur Micoulaud-Franchi, Fabrice Bartolomei, Eric Guedj.. Positron emission tomography in patients with psychogenic

Utility of Computed Tomography to Predict Ventricular Arrhythmias in Patients With Nonischemic Cardiomyopathy Receiving Cardiac Resynchronization Therapy... Utility of Computed

Left ventricular wall thickness assessed by cardiac computed tomography and cardiac resynchronization therapy outcomes... Left ventricular wall thickness assessed by cardiac