• Aucun résultat trouvé

View of The Validity of an Objective, Inexpensive Measure of Relaxation

N/A
N/A
Protected

Academic year: 2021

Partager "View of The Validity of an Objective, Inexpensive Measure of Relaxation"

Copied!
3
0
0

Texte intégral

(1)

208 CanadianJournal of Counselling Revue Canadienne de Counseling 1989, Vol. 23:2

T h e V a l i d i t y o f a n O b j e c t i v e , I n e x p e n s i v e M e a s u r e o f R e l a x a t i o n

M a r t i n Weinstein, J o n a t h a n C. Smith, L y n n Turovetz Roosevelt University

Relaxation techniques such as progressive relaxation and meditation have become an integral part of the vast majority of stress management programs (Woolfolk & Lehrer, 1984). Heart rate is one of the most widely used hard signs of relaxation (Lichstein, 1988; Shapiro & Walsh, 1984; Woolfolk & Lehrer, 1984). While sophisticated E K G equipment may provide the ideal in accuracy and objectivity, such equipment is costly and often requires extensive training. In addition, polygraph readings can be difficult to take in naturalistic settings. There are, however, convenient and feasible alternatives. Two researchers have advocated self-monitored measures of heart rate (Hiebert, 1980; Lamott, 1975). Here subjects simply take their own pulses (either wrist or neck) for 30 seconds. Hiebert, Dumka and Cardinal (1983) studied the validity of this procedure by comparing self-monitored and machine-monitored pulse rate. They reported a .94 correlation between the two techniques.

Although self-monitoring provides an inexpensive alternative to polygraph equipment, it presents two problems. Perhaps the most significant is subject bias (i.e., the tendency to misread or misreport on the basis of personal expectations). Further, self-monitoring is an intru-sive procedure: the taking of one's own pulse may not only increase arousal, but interfere with completing an exercise sequence smoothly. In the past several years rapid development in technology has led to new, inexpensive and convenient ways of measuring pulse. Typically such devices (often found in athletic supply stores at a cost of approxi-mately $100) weigh less than one pound, are battery operated, and provide immediate digital feedback of heart rate. Three types of instru-ments are widely available. One involves a finger clamp; another, a monitor held in the hand; a third involves attaching a nonintrusive sensor to the earlobe. The aim of the present investigation was to examine whether such devices might provide a reasonable alternative to the polygraph.

METHOD Subjects

The subjects were 20 patients (9 males, 11 females) who had come for annual physical examinations from two specialists in Internal Medicine.

(2)

CanadianJournal of Counselling/Revue Canadienne de Counseling/ 1989, Vol. 23:2 209

Apparatus

The electrocardiogram (EKG) was taken with a 12-lead Burdick poly-graph, model EK5A. Pulse rate was assessed using the Deluxe Pulse-minder Heart Speedometer, model 8629 (Computer Instruments Cor-poration). With this device a photoelectric pulse sensor is clipped to the earlobe. The sensor is connected by wire to a small box (approximately 3"+5"x 1") which displays (a) direct pulse rate signalled by a flashing light (and, if desired, by a tone), (b) pulse rate in beats per minute (estimated) from the three previous beats), and (c) number of seconds and minutes elapsed.

Procedure

For the subject's EKG, an electrode was placed on each leg and shoulder. A fifth electrode was placed in the V l position at the third and fourth intercostal space on the right side of the chest. To measure pulse, the pulse sensor was attached to the subject's earlobe. First the poly-graph and the pulse monitor were turned on. After 10 seconds, a 20-second reading was taken. During this period the number of flashes on the pulse monitor was counted and recorded. (The indicator of the number of beats per minute was not used because this number changes rapidly, leading to the likelihood of considerable recording errors). A second experimenter counted the number of Q R S complexes, the most pronounced and easily identifiable portion of the electrocardiogram. This experimenter was kept blind to the pulse monitor count. RESULTS AND DISCUSSION

The mean number of pulses for the 20-second period as measured by both the polygraph and pulse monitor was 20.65 (5/)=4.48). The correlation between the readings on the two devices was 1.0.

Results indicate that the pulse monitor is an accurate measure of pulse rate. Thus, the device appears to provide an inexpensive, objective means for therapists to monitor closely the progress made by clients learning relaxation techniques as well as a means for clients to monitor their own progress when practicing at home. While the E K G may provide significantly more information, such information is typically of little importance for those learning relaxation and is rarely reported in relaxation studies.

Clients could observe changes in heart rate just prior to beginning relaxation and at its conclusion with the device held in the client's hand or placed on a nearby table. Having an objective means of measuring progress may encourage clients to practice regularly as they may feel there is a more clear way to assess their progress. Therapists could indicate to clients that they should regularly chart changes at home which may provide further encouragement.

(3)

210 CanadianJournal of Counselling/Revue Canadienne de Counseling/1989, Vol. 23:2

In addition, the pulse monitor could be used for research in both applied and laboratory settings. Because the device is inexpensive and requires little training, it opens up the opportunity for more research, particularly when research budgets are severely limited and high levels of portability are required.

References

Heibert, B. (1980). Self-relaxation: Learn it, use it. Coquitlam: Per Man Consultants. Hiebert, B., Dumka, L., & Cardinal, J. (1983). The validity of self-monitored

physio-logical indices of relaxation. Canadian Counselor, 18, 47-48. Lamott, K. (1975). Escape from stress. New York: Putman. Lichstein, K. L. (1988) Clinical relaxation strategies. New York: Wiley.

Shapiro, D. H. & Walsh, R. N. (Eds.) (1984). Meditation: Classical and contemporary perspectives. New York: Aldine.

Woolfolk, R. L. & Lehrer, P. M. (Eds.) (1984). Principles and practice of stress management. New York: Guilford Press.

About the authors:

Martin Weinstein is currently chairman of the Psychology Department at Roosevelt University in Chicago, Illinois. His research interests are in the areas of preparation techniques for psychotherapy and mechanisms underlying relaxation techniques such as progressive relaxation.

Jonathan C. Smith is founder and director of Roosevelt University's Stress Institute. His is the author of four books, including two recent publications on cognitive-behavioural approaches to relaxation.

Lynn Turovetz is completing her Master's Degree in Clinical Psychology at Roosevelt University. She is an intern and works parttime at Proviso Family Services, a community mental health center in the suburbs of Chicago.

Address correspondence to Martin Weinstein, Psychology Deptartment, Roosevelt University, 430 S. Michigan Avenue, Chicago, Illinois, 60605.

Références

Documents relatifs

La circulation dans le système se fait par effet thermosiphon ; le fluide se met en mouvement des parties les plus chaudes (capteur plan) vers les parties les plus froides (bac du

Again, the colour image is converted into a grey-scale image and then the binary image obtained manually by means of GIMP (Figure 6, central panel).. As we can see, the white cell

A decision regarding the polarity of a financial news bases on the interplay of a social collection of agents (a swarm), which serve and assist the Artificial Companion while

The calculated SEDM lineshape using the superoperator formalism and assuming this spin flip relaxation mechanism shows a peak at this position for a rela- xation time of te =

Several authors have advocated utilizing self-monitored measures of heart rate, respira- tion rate and finger temperature as indicators of relaxation (cf.. Such procedures have

Figure 2 – Representative pictures of the root system as visualized using the PhenoRoots platform. A) Image of the root system of a cotton plant analyzed using the ImageJ toolset:

Socio-economic impacts : Mainly depend on business models (contract farming or not; labour intensity of production model) and land tenure context. Impacts on territory scale :

Compilation of the composite elastic modulus deduced from nano and microindentation tests applied to the porous oxide film as a function of the relative indentation depth where the