• Aucun résultat trouvé

3D analysis of the osteonal tissue in human cortical bone

N/A
N/A
Protected

Academic year: 2021

Partager "3D analysis of the osteonal tissue in human cortical bone"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: hal-02441874

https://hal.archives-ouvertes.fr/hal-02441874

Submitted on 16 Jan 2020

HAL is a multi-disciplinary open access

archive for the deposit and dissemination of

sci-entific research documents, whether they are

pub-lished or not. The documents may come from

teaching and research institutions in France or

abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est

destinée au dépôt et à la diffusion de documents

scientifiques de niveau recherche, publiés ou non,

émanant des établissements d’enseignement et de

recherche français ou étrangers, des laboratoires

publics ou privés.

3D analysis of the osteonal tissue in human cortical bone

Rémy Gauthier, Hélène Follet, Cécile Olivier, David Mitton, Françoise Peyrin

To cite this version:

(2)

25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria

3D ANALYSIS OF THE OSTEONAL TISSUE IN HUMAN CORTICAL BONE

Rémy Gauthier (1,2), Hélène Follet (3), Cécile Olivier (2), David Mitton (1) and Françoise Peyrin (2)

1.Univ Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France; 2.Univ Lyon, CNRS UMR 5220, Inserm U1206, INSA Lyon, Université Claude Bernard Lyon 1, Creatis, F69621 Villeurbanne Cedex, France; 3.Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS

UMR1033, F69008, Lyon, France.

Introduction

The difficulty to predict human cortical bone fragility is partly due to its complex multiscale architecture1. In

particular, osteons, considered as bone structural units arise through the remodeling process that occurs at the canals surface, and are assumed to play a major role in bone mechanical properties2.

If 2D data can be found in the literature, there is, however, still few 3D quantitative data regarding bone osteonal systems3. This lack of data can be explained by

the difficulty to distinguish the osteon from the interstitial tissue using standard 3D imaging techniques. However, due to its sensitivity, synchrotron radiation micro-computed tomography (SR-µCT) in the quantitative phase retrieval mode was shown to be a good candidate to enhance the contrast of the osteons4.

The objective of the current study was to investigate morphometric parameters of osteons in human cortical bone and their relation with osteocyte lacunae and micro-cracks using SR quantitative phase µCT.

Materials and Methods

Rectangular cortical bone samples were extracted and prepared from eight female donors radii (50 to 91 y.o.). The image acquisition was performed on beamline ID19 at the European Synchrotron Radiation Facility (ESRF, France) using a “pink beam” with an energy of 31 keV. The effective pixel size on the detector was 0.7 µm. Phase contrast was obtained by propagation with a sample-to-detector distance set to 40 mm and phase retrieval was performed using Paganin’s method5. The

final Volume Of Interest (VOI) was 1x1.4x1.4 mm3.

The osteons were segmented manually using Avizo software (Thermal Fischer Scientific). The Haversian canals, osteocyte lacunae and micro-cracks were segmented automatically using a home-made previously described method6.

The bone volume (BV) was considered as being the complementary of the Haversian canals volume. The osteons volume fraction (Ost.V/BV), lacunar density (Lc.N/BV) and micro-cracks volume fraction (µCr.V/ BV) were computed both in the osteonal volume (Ost.V) and interstitial volume (Inter.V). A Wilcoxon test for paired samples was used to investigate for differences between properties in osteonal and interstitial volumes.

Results and discussion

Table 1 reports the quantitative morphometric values and Figure 1 illustrates the original gray level volume and after the segmentation of the different structural features.

Table 1: Morphometric parameters (Average (SD)).

Morphometric

parameters Bone Ost.V Inter.V

Ost.V/BV (%) 43.2 (8.4) Lc.N/BV (mm-3) 19621* (2171) 20832 (2522) 18621 (1682) µCr.V/BV (%) 8.3 * (7.4) 2.4 (2.9) 12.2 (10.2)

*Significant difference between Ost.V and Inter.V (p < 0.05)

The difference of lacunar density between osteonal and interstitial tissue may reflect the remodeling process occurring within the osteons. The higher volume fraction of micro-cracks in the interstitial tissue suggests that they are formed in this older tissue, and that they cannot enter the osteons.

a. b.

Figure 1: 3D rendering of the VOI from a donor radius cortical bone (50 y.o.). a.: original phase contrast; b.: segmented volume (osteons surfaces: green, osteocytes lacunae: yellow, micro-cracks: red). Scale bar = 100 µm. These novel 3D quantitative results regarding the osteocyte lacunae and micro-cracks properties in osteonal and interstitial tissue highlight the major role played by the osteons as structural units within human cortical bone.

References

1. Seeman and Delmas, N Eng J Med, 354:2250-2261, 2006 2. Burr et al., J Biomech, 21:939-945, 1988

3. Hannah et al., Bone, 47:866-871, 2010 4. Langer et al., PLoS One, 7:e35691, 2012 5. Paganin et al., J Microscopy , 206:33-40, 2002 6. Gauthier et al., J Struct Biol, 204:182-190, 2018

Acknowledgements

Références

Documents relatifs

In the current study, we assessed the morphometric parameters of human cortical bone on eight paired femoral diaphyses, femoral necks, and radial diaphyses.. Results show that

More recently, further studies, comprehensively quoted and reviewed in the papers of this Special Issue, have been performed using the above-mentioned invasive

3D analysis of the osteonal and interstitial tissue in human radii cortical bone.. Rémy Gauthier, Helene Follet, Cécile Olivier, David Mitton,

3D X-Ray imaging of bone tissue from micro to nano scale and associated inverse

Compared with the Flight group, the cortical bone structure, material properties and osteocyte parameters in the Habitat Control group were preserved, even when endosteal

Therefore, in this study we investigate the influence of critical mechanical loading on 3D micro-crack morphology in human cortical bone from different paired

While interictal and preictal discharges are transient events, epileptic seizures are complex dynamic events with variable oscillatory components (Baud et al., 2018; Eissa et

Voxel-based analysis was then applied in a 3D histology study investigating the impact of the over-expression of the ADAM30 gene on Aβ plaque deposition in a transgenic mouse model