(1)Copyright © NRC 1941 - 2019 World Rights Reserved © CNRC 1941-2019 Droits réservés pour tous pays. NATIONAL RESEARCH COUNCIL OF CANADA ASSOCIATE COMMITTEE ON THE NATIONAL BUILDING CODE. ERRATA to the SUPPLEMENT TO THE NATIONAL BUILDING CODE OF CANADA 6980. Ottawa January 1981.

(2) Copyright © NRC 1941 - 2019 World Rights Reserved © CNRC 1941-2019 Droits réservés pour tous pays. ERRATA t o the Supplement t o the National Building Code of Canada 1980 Page. Reference. Correction. 34. Table 2.3.A.. In the heading change "TIMED" to read "TIME.". 36. Table 2.3.D.. In the heading change "Article 2.3.6." t o read "Article 2.3.7.". 37. Table 2.3.E.. In the heading change "Article 2.3.7." t o read "Article 2.3.8.". 38. Table 2.3.F.. In the heading change "Article 2.3.8." to read "Article 2.3.9.". Table 2.6.E.. In the third entry of Column 3 change "0.64 mm o.c." to read "200 mm 0.c.)'. In the first line of the second entry in Column I change "in" t o read "if.". Table 2.8.A.. In the heading after "Factor f" add notations "(3), (4)." Add the following Notes (3) and (4) at the end of the Table: "") Where the factor, "f", selected from Column 3 results in a "t" greater than 300 mm, the appropriate factor "f" in Column 4 is applicable.. Where "p" is equal to or less than 3 per cent and the factor, "f," selected from Column 4 results in a "t" less than 300 mm, the minimum thickness should be 300 mm." L C 25" ''25 w In the first entry of Column 5 change - t o read -. 1 00 50. (4). Table 3.1.A. Clauses (g) and G ). Change " 120 ft" to read "36 m.". Sentence (5). In the last line change "(13)" to read "(14).". Third Paragraph, Clause (c). In the second line change "Graph 10" to read "Graph 9.". Sentence 10. In the second line change "Sentence (6)" to read "Clause (5)(b).". Table A-1. In the heading of Column 4 change "S16.1-1978" S 16.1-M78. ". Paragraph 33, seventh line. Change "(> 0.5 per cent of surface area)" to read "(< 0.5 per cent of surface area). ". t o read "CAN3-. Change "See Fig. B-19" to read "See Fig. B-21." Fig. B-23, fourth and seventh columns Paragraph 34. In the last line change "H-6" to read "H-7.". Paragraph 35. In the last line change "H-7" t o read "H-6.". Paragraph 21, Case 3, Clause (b). In the fourth line change "CSA (340.21-1976, 'Structural Quality Steel' " to read "CSA G40.21-M1978, 'Structural Quality Steels'.". Paragraph 2 1 , Case 5. In the first line change "infills or" to read "infills of.". Paragraph 3 1. Change equation "(9)" t o read. "Vx = F,. +. n. 1 F,.', 1 = x.

(3) #. Copyright © NRC 1941 - 2019 World Rights Reserved © CNRC 1941-2019 Droits réservés pour tous pays. Page. Reference. Correction. Paragraph 40. In the fourth line from the top of the page change "ith mode" to read "yi for the ith mode.". Paragraph 46. In the last formula change "Cjk9' t o read "ejk.". 239 and 240. Reference No. (14) and (38). Change "(29)" t o read "(31).". 239. Reference No. (26) t o (28). Change "(14)" to read "(16).". 239 and 240. Reference No. (29) and (37). Change "(30)" t o read "(32).". 243. to read "+'." Note * at bottom of Change page Table L-6 In Column 3 change "5 to 1" t o read "0.5 to 1.". "+". Paragraph 24. In the last line change "2" t o read "2 s.". List of Standards. Change "C3 15-78b" to read "C315-78c." In the last line of the title of ASTM Standard C646-78a change "Guage" t o read "Gauge. ". List of Standards. Delete reference t o CGSB 19-GP-15M, "Sealing Compound, Multi Component, Polyurethane Base, Chemical Curing.". List of Standards. Change "38-GP-8M" to read "37-GP-8M.". List of Standards. Change the Code reference for CAN2-5 1.33-M77 from "9.26.3.3." "9.26.3.4.". List of Standards. Change the Code reference for CAN3-A23.3-M77 from "4.1.4.2.(6)" read "4.1.4.2.(8).". List of Standards. In the title opposite A123.7-1973 change "Constructing" to read "Construction of.". List of Standards. Change "0177-M 1978" to read "0177- 1977.". List of Standards. Change "CAN3-S350-M79" to read "S350-M79" and its Code reference from "8.2.6.1." t o read "8.1.1.3.". to read to.

(4)

Références

Documents relatifs

Plastic Pipe, Fittings and Solvent Cement Used Above Ground 1 Plastic pipe, fittings and solvent cement used inside or under a building in a drainage or venting system shall conform

Test Procedures 1 When Measure G is used to limit smoke movement as provided in Chapter 3, "Measures for Fire Safety in High Buildings" of the Supplement to the NBC, a switches at

liquids permitted to be located outside of a storage room or storage cabinet, in any one fire co~npartrnent of a building, shall not be more than a 600 L of flammable liquids

Concrete in Contact with Sulphate Soil 1 Concrete in contact with sulphate soil deleterious to normal cement shall conform to the requirements in Section 16 of CAN3-A23.1,

Delete the first 4 lines and substitute: 2 Where there is a common attic or roof space above more than 2 suites of residential occupancy or above more than 2 patients' bedrooms,

The First and Second Revisions dated January 1986 and January 1987, respectively, included updating of the referenced documents to 30 June 1986.. The revisions contained herein

Par exemple, lorsqu'un bâtiment doit être protégé par des extincteurs automatiques à eau, la norme NFPA 13 relative ti l'installation des extincteurs exige que le vide dissimulé

Ajouter l'article suivant: 1 Sous réserve du paragraphe 3, dans les bâtiments ayant des ascenseurs qui desservent des étages au-dessus du premier étage et qui sont équipés