• Aucun résultat trouvé

DIAGNOSTIC PAR DIFFUSION THOMSON D'UN PLASMA CHAUFFÉ PAR LASER

N/A
N/A
Protected

Academic year: 2021

Partager "DIAGNOSTIC PAR DIFFUSION THOMSON D'UN PLASMA CHAUFFÉ PAR LASER"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: jpa-00215252

https://hal.archives-ouvertes.fr/jpa-00215252

Submitted on 1 Jan 1973

HAL is a multi-disciplinary open access archive for the deposit and dissemination of sci- entific research documents, whether they are pub- lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

DIAGNOSTIC PAR DIFFUSION THOMSON D’UN PLASMA CHAUFFÉ PAR LASER

C. Stenz, E. Fabre

To cite this version:

C. Stenz, E. Fabre. DIAGNOSTIC PAR DIFFUSION THOMSON D’UN PLASMA CHAUFFÉ PAR LASER. Journal de Physique Colloques, 1973, 34 (C2), pp.C2-16-C2-16. �10.1051/jphyscol:1973205�.

�jpa-00215252�

(2)

JOURNAL DE PHYSIQUE Colloque Cl, supplément au n° 11-12, Tome 34, Novembre-Décembre 1973, page C2-16

DIAGNOSTIC PAR DIFFUSION THOMSON D'UN PLASMA CHAUFFÉ PAR LASER

C. STENZ et E. FABRE

Laboratoire de Physique des Milieux Ionisés, Ecole Polytechnique Equipe de Recherche associée au CNRS, France

Résumé. — On étudie au moyen de la diffusion Thomson le chauffage par absorption d'un faisceau laser CO2, par un plasma au voisinage de la densité de coupure

(8 x lOis < n

e

^ 9

x

lOis

e

/cm3).

Le laser sonde utilisé est un laser à rubis dont la puissance crête est de 100 MW. Le spectre de la lumière diffusée à 90" est analysé à l'aide d'un dispositif multicanal à 10 voies dont la résolution est de 13 Â par canal. Dans ces conditions, et pour une température électronique du plasma cible de l'ordre de 10 eV, la valeur initiale du paramètre de diffusion a = 1,05 x 10

-8

(n

e

/Te)

ln

est de l'ordre de 10, et la position des composantes satellites électroniques par rapport à la raie laser, donnée par AA

S

(Â) 1,44 x 10-7 „i/2 [i 4. 2,7 x 10i« Te/ne]

1

/

2

est de l'ordre de ± 435 A.

Une élévation de la température électronique, résultant du chauffage, comprise entre 50 et 100 eV, contribue à modifier a dont la valeur finale sera comprise entre 6 et 3 respectivement. Les composantes électroniques sont alors déplacées par rapport à leur position initiale d'une quantité de l'ordre de 25 A à 55 Â. Les modifications du spectre diffusé et notamment le déplacement des composantes électroniques permettront donc une mesure précise de l'élévation de Te.

Abstract. — We study by means of Thomson scattering, the heating of a plasma near the cutoff density by CO2 laser beam absorption.

Using a multichannel spectral Analyzer (10 channels, 13 Â spectral resolution per channel) the scattered light is observed at right angles to the beam from a 100 MW Q-ruby laser focused in the center of the target plasma. At cutoff density and an électron température of 10 eV, the initial value of the scattering parameter a is of the order of 10, and the électron satellite lines are spaced close to ± 435 Â from the incident laser wavelength. As a resuit of heating, the électron température increases from an initial value of 10 to a final value between 50 and 100 eV, and a changes from 10 to a value between 3 and 6.

The electronic components are then shifted from their initial position by a quantity ranging from 25 Â to 55 A.

The modification of the spectral distribution of the scattered light and specially the position of the électron satellite lines will give a measurement of the électron température increase.

Article published online by EDP Sciences and available at http://dx.doi.org/10.1051/jphyscol:1973205

Références

Documents relatifs

Integrating the power spectral densities of the magnetic and electric fields in the 10 to 500 Hz frequency range shows that the energy density of waves is higher inside the

- The data acquisition system is fully automatic except for manual setting of the time of measurement, the radial scan position, and the laser energy. The output of

To this aim, I have generated a mouse line named mTOR MKOKI which is defective in endogenous muscle mTOR (mTOR MKO), while expressing a FLAG-tagged muscle-specific

It has also been shown that measuring the path-length distribution, and using the measured data in the standard DWS theory (instead of calculations based on the diffusion

2- Représentez le vecteur champ magnétique au niveau de chacun des conducteurs ; 3- En déduire la direction et le sens des forces électromagnétiques exercées sur les conducteurs

2- Représentez le vecteur champ magnétique au niveau de chacun des conducteurs ; 3- En déduire la direction et le sens des forces électromagnétiques exercées sur les conducteurs

This method is only based on calculations performed on experimental data, no model is used and results do not depend on the accuracy of the different hypothesis, the probe

Fluorescence spectra similar to the figure 1 inset were measured for various excitation energies in an effort to detect spectral changes as a function of the depth