• Aucun résultat trouvé

Immediate rehabilitation of completely edentulous jaws with fixed prostheses supported by implants placed into fresh extraction sockets and in healed sites: a 4-year clinical evaluation

N/A
N/A
Protected

Academic year: 2022

Partager "Immediate rehabilitation of completely edentulous jaws with fixed prostheses supported by implants placed into fresh extraction sockets and in healed sites: a 4-year clinical evaluation"

Copied!
9
0
0

Texte intégral

(1)

Article

Reference

Immediate rehabilitation of completely edentulous jaws with fixed prostheses supported by implants placed into fresh extraction sockets

and in healed sites: a 4-year clinical evaluation

COVANI, Ugo, et al .

Abstract

To evaluate the outcome of treatment in the rehabilitation of edentulous jaws with early loaded full-arch screw-retained prostheses after up to 4 years of function.

COVANI, Ugo, et al . Immediate rehabilitation of completely edentulous jaws with fixed prostheses supported by implants placed into fresh extraction sockets and in healed sites: a 4-year clinical evaluation. Implant Dentistry , 2012, vol. 21, no. 4, p. 272-9

DOI : 10.1097/ID.0b013e31825885e0 PMID : 22814550

Available at:

http://archive-ouverte.unige.ch/unige:111700

Disclaimer: layout of this document may differ from the published version.

1 / 1

(2)

Downloadedfromhttps://journals.lww.com/implantdentbyBhDMf5ePHKav1zEoum1tQfN4a+kJLhEZgbsIHo4XMi0hCywCX1AWnYQp/IlQrHD3mH5nK33R3QhMrhl8umFsejPq3oWQK1KotQiBofuxvi2Q4daa+mr13w==on11/07/2018

Downloadedfrom https://journals.lww.com/implantdentby BhDMf5ePHKav1zEoum1tQfN4a+kJLhEZgbsIHo4XMi0hCywCX1AWnYQp/IlQrHD3mH5nK33R3QhMrhl8umFsejPq3oWQK1KotQiBofuxvi2Q4daa+mr13w==on

11/07/2018

Immediate Rehabilitation of Completely Edentulous Jaws With Fixed Prostheses Supported by Implants Placed Into Fresh

Extraction Sockets and in Healed Sites:

A 4-Year Clinical Evaluation

Ugo Covani, MD, DDS,* Bruno Orlando, DDS,†Aniello D’Ambrosio, MD, DDS,‡Vincenzo Bucci Sabattini, MD, DDS,§

and Antonio Barone, DDS, PhDk

T

itanium dental implants have made fixed prostheses suitable for completely edentulous pat- ients, and most studies have reported predictable results when the proper guidelines are correctly followed.1–3 According to the Brånemark 2-stage protocol, after implant placement, a period of 3 to 6 months in the absence of occlusal loading was required to achieve successful osseointegration.4–6 This strict protocol required the wearing of a temporary prosthesis between sur- gery and prosthetic rehabilitation to maintain function and aesthetics.

Over the past 2 decades, however, some of the original concepts have been reassessed to satisfy the patients’ expectations for shorter rehabilitation time, improved aesthetic outcomes, and increased comfort during healing.

Because the recommended healing time that is necessary before implants can be

loaded has been proposed as a result of clinical observations rather than biolog- ical documentation, clinicians have questioned whether this period was actually necessary to achieve the high- est success rate or if it could in fact be shortened. The concept of immediate loading was therefore introduced.7

It has been seen that immediate loading reduces functional discomfort and also improves the outcome of the implants, thus avoiding the risk of implant failure due to the unexpected overload imposed on the top of the fixtures in the early healing phase.8

Survival rates of 96% to 100%

are reported for immediately loaded

full-archfixed prosthesis in the mandi- ble.9–11Few studies have evaluated the success of immediately loaded implants in the edentulous maxilla, but the pre- liminary results seem encouraging.12,13 Nevertheless, these protocols still include the use of a provisional remov- able device during the healing period between tooth extraction and implant placement, for instance, in those partially edentulous patients in whom extra- ction of all the remaining teeth was indicated and planned to undergo an implant-supported rehabilitation.14 For patients who have their own teeth but will lose them all and intend to receive an implant-supported rehabilitation, it

*Full Professor, Department of Surgery, University of Pisa, Pisa, Italy.

†PhD Student, Department of Oral and Biomedical Sciences and Technologies, University of Genova, Genova, Italy.

Private Practice, Napoli, Italy.

§Private Practice, Magenta, Italy.

kAssistant Professor, Dept. of Oral and Biomedical Sciences and Technologies, University of Genova, Italy.

Reprint requests and correspondence to: Bruno Orlando, DDS, Tirreno Dental Institute, Versilia General Hospital, Via Aurelia 335, 55041 Lido di Camaiore, Italy, Phone: +390584-6059889, Fax: +390584-6058716. E-mail: b_orlando@virgilio.it

ISSN 1056-6163/12/02104-272 Implant Dentistry

Volume 21Number 4

Copyright © 2012 by Lippincott Williams & Wilkins DOI: 10.1097/ID.0b013e31825885e0

Purpose: To evaluate the out- come of treatment in the rehabilita- tion of edentulous jaws with early loaded full-arch screw-retained pros- theses after up to 4 years of function.

Methods: Patients with com- pletely edentulous maxillae and/or mandibles, or presenting natural teeth with a poor or hopeless prog- nosis, received 6 implants each in the mandible and/or 8 in the upper jaw. All patients received a full-arch prosthetic reconstruction.

Results: A total of 19 patients were treated with a total of 164

implants. One hundred nineteen implants were placed immediately after tooth extraction, and 45 implants were placed in healed sites. Overall, 8 implants failed, leading to a 4-year cumulative survival rate of 95.1%.

Conclusions: The rehabilitation of the edentulous maxilla and man- dible with an early loaded prosthesis represents a viable alternative treat- ment to classic loading protocols.

(Implant Dent 2012;21:272–279) Key Words: immediate loading, immediate implants, cumulative survival rate

(3)

would be interesting to get a full-arch fixed prosthesis on implants immedi- ately after tooth extraction, in 1 single surgical procedure.

The results reported by several clinical studies suggested that placing implants at the time of tooth removal may have many advantages compared to the traditional approach, enabling the placement of wider and longer implants.15,16

Few reports are available in the literature regarding the possibility of immediate/early functional loading of implants placed into fresh extraction sockets. Some studies reported that immediately loaded implants placed in fresh extraction sockets are associated with a higher risk of failure compared to immediately loaded implants inserted into healed sites.17,18Nonetheless, other studies described similar success rates for premature loaded implants inserted in mature bone and immediately after tooth removal.19–23

Considering these premises, the aim of the present study was to evaluate the survival rate of implants placed in healed sites and fresh extraction sockets and immediately loaded with a full-arch screw-retained prosthesis after up to 4 years of function.

MATERIALS AND METHODS

Patient Population

Between February 2003 and Janu- ary 2006, a total of 19 patients (13 women and 6 men) ranging in age from 39 to 72 years, with a mean age of 60.26 years, were treated with a total of 164 implants.

All the patients requiring dental implants for a full-arch implant- supported rehabilitation who were 18 years or older and able to sign an informed consent form were considered eligible for inclusion in this study.

Eligible patients had to have sufficient bone volume allowing placement of implants, which should be used for a full-arch implant-supported rehabilita- tion. Patients with completely edentu- lous jaws and/or presenting natural teeth with a hopeless prognosis were included in the study. All the included patients were scheduled for a screw-retained full- arch rehabilitation selected on the basis

of the following inclusion criteria: age

$18 years; rehabilitation with oral implants considered elective; physical ability to tolerate conventional surgical and restorative procedures; all implants could be seated with a torque$45 N.cm and had initial primary stability; and finally had signed an informed consent form.

Patients were not included in the study on the basis of the following exclusion criteria:

• presence of acute infection or inflammation in the area scheduled for implant placement;

• systemic diseases that would con- traindicate implant surgery;

• severe skeletal jaw discrepancies (Class V to VI according to the classification of Cawood and Howell24);

• treatment with therapeutic radia- tion in the head or neck regions within the past 12 months;

• severe bruxism or clenching;

• poor oral hygiene;

• pregnancy.

A smoking habit was not consid- ered an exclusion criterion, but patients who smoked more than 10 cigarettes per day were excluded and those who smoked less than 10 cigarettes per day were advised to attend counseling sessions.

Preoperative Assessment

A complete examination of hard and soft oral tissues was conducted for each patient to assess the bone volume of the scheduled implant sites. Each case was accurately evaluated examin- ing diagnostic casts for the intraarch relationship, periapical and panoramic radiographs, and computed tomogra- phy if necessary.

Before surgery, the diagnostic casts were mounted in an articulator, and a diagnostic wax-up was prepared in which occlusion, aesthetic parameters, and relation between the teeth and alveolar ridge were evaluated. On the base of this setup, a cross-arch pro- visional template and a surgical custom guide in transparent heat-processed acrylic resin were provided by the dental technician.

Surgical Procedures

Antimicrobial prophylaxis was prescribed with 2 g of amoxicillin 1 hour before the surgery, and thereafter 1g twice per day for 5 days. All patients were operated without sedation under local anesthesia induced by infiltration with articaine/epinephrine (1:100000), and each patient received 6 implants in the mandible and/or 8 in the upper jaw.

A crestal incision, or an intrasulc- ular incision in the cases of immediate postextraction implants, was made from thefirst molar to thefirst contra- lateral molar, with one releasing incision at the midline to allow for an easierflap reflection. After this, a full mucoperiosteal flap was raised to expose the sites for implant placement.

In the cases of immediate postextrac- tion implants, the compromised teeth were carefully removed, and the residual extraction sockets were thor- oughly debrided. A periodontal probe was used to assess the integrity of the bony walls of the extraction sockets. If a lack of 1 or more bony walls was detected, the postextraction site was excluded. Subsequently, implants with a bioceramic, grit-blasted, and acid- etched surface (Ossean; Intra-Lock International, Inc, Boca Raton, FL) were placed using a sterile surgical technique, as recommended by the manufacturer, with the aid of surgical templates and inserted directly in some of the fresh extraction sockets as well as into healed edentulous sites adjacent to the sockets. Implants were inserted with a minimal torque of 45 Ncm. The resistance to implant insertion was evaluated with a hand torque controller device (Torque-Lock; Intra-Lock Inter- national, Inc). Depending on the size and anatomy of the extraction socket, if there was a bone defect larger than 2 mm between the bone walls and the implant body, it was grafted with autogenous bone chips collected during implant site drilling. According to the panoramic radiograph, in some of the patients, the residual bone height under the maxillary sinus was#8 mm. The osteotome sinus floor elevation tech- nique was applied by light malleting as previously described25; no grafting biomaterials were used during the osteotome sinusfloor elevation.

(4)

Flat abutments (FlatOne; Intra- Lock International, Inc) were then con- nected to the implants by applying a torque of 35 N.cm. After placing transfer copings on the abutments, the mucoperiosteal flaps margins were adjusted to adapt to the abutments and then accurately sutured.

Prosthetic Procedures

After the surgical procedure, impressions with impression copings were taken using a polyether elasto- meric material (Impregum Penta; 3M ESPE, Milan, Italy) and the provisional template; the analogs were then attached to the transfer copings in the impression and sent to the dental labo- ratory. After impression, the centric relation was registered with wax (Dental Wax; Moyco Technologies) and, subsequently,flat abutment cover screws were seated. The working model produced in the laboratory incorporated implant analogs. The cast- ing cylinders were placed onto the analogs and connected with a small amount of self-curing resin and the structure“waxed up.”On the following day, the vertical dimension, occlusion, aesthetics, phonetics, and fit of the wax-up were checked intraorally.

After the wax up was verified, a rigid 1-piece Cr-Co framework was fabri- cated. Finally, the full-arch screw- retained prosthesis was finalized and inserted within 48 hours after surgery.

The abutment screws were tightened, and the occlusion was carefully checked. At the time of prosthesis delivery, periapical radiographs were taken to check the presence of any mis- fits between the prosthetic framework and the implants. All prostheses were screw retained and fabricated with a metal framework combined with resin teeth.

Postoperative Care

Postsurgical analgesic treatment was prescribed with 100 mg of nime- sulide twice daily for the following 3 days. Patients were instructed to eat a soft diet for the first 8 weeks after implant placement. Oral hygiene was reinstructed with the soft manual tooth- brush and additionally with appropri- ate-sized interdental brushes.

Follow-up Evaluations

Patients were scheduled for follow- up evaluations at 6 and 12 months after implant insertion and then every 6 months up to a period of 4 years. At each visit, periapical radiographs were taken to evaluate the periimplant radio- lucency. Oral hygiene reinstructions were given when considered necessary.

All mobile implants were recorded as failures. All implants without signs of mobility, without pain or discomfort on pressure, and exhibiting radiographic evidence of osseointegration were con- sidered survivals. Cumulative implant survival over time was assessed using the Kaplan-Meyer analysis. The sur- vival function is used to represent the probability that implant survive from their placement to sometime beyond.

During the observation period, implant may fail, survive, or “be censored.” Censored observations arise whenever the dependent variable of interest repre- sents the time to a terminal event, and the duration of the study is limited in time. For some implants, the event of interest (failure) has occurred, and therefore, we know the exact survival time (their survival time is uncensored), whereas for others, it has not occurred, so the survival time exceeds the obser- vation time. An implant is censored when follow-up ends before the occur- rence of the event (failure) or comple- tion of the full period of observation (the observation of this implant is incomplete). About the result for this observation, it is known only that it occurs later than its indicated censor- ing time (Censoring is a form of mis- sing data problem that is common in survival analysis, the branch of statis- tics that deals with failure in biological and mechanical systems26). A log-rank test was used to explore the differences between the survival curves stratified for the variable of interest. The investi- gation considered the following param- eters: time of implant placement; jaw position; implant diameter and length;

andfinally, any additional augmentation procedures (osteotome sinusfloor eleva- tion). The null hypothesis, being no dif- ferences between groups, was rejected asP,0.05. All evaluations were per- formed using SPSS software version 6.1.2 for Windows.

RESULTS

No patients dropped out of the study, and the evaluation data of all patients was used for the statistical evaluation. In total, 132 of 164 implants inserted were of narrow diameter (3.3 mm) and the remaining 32 implants were of wide diameter (5 and 5.5 mm).

One hundred thirty-threefixtures were 13 and 15 mm long, whereas the remaining 31 were 8 mm long. Three patients received implant-supported reconstruction both in their maxilla and mandible, so that these 164 implants were distributed over 16 upper jaws and 6 lower arches. No patient dropouts were recorded during the observation period. Patients healed with minor discomfort or swelling and no surgical complication was recorded.

Four of the 16 upper jaws were healed edentulous maxilla, whereas 12 had some hopeless teeth that needed to be removed. Forty-nine implants required augmentation procedures and were inserted after a simultaneous sinusfloor elevation using the osteotome tech- nique. All the 6 lower arches treated with full-arch implant rehabilitation presented residual teeth, which were judged to be unrecoverable.

One hundred nineteen implants were placed immediately after tooth extractions (immediate implants), and 45 implants were placed in healed sites (delayed implants). One hundred twenty-eight implants were placed in the maxilla (85 immediate and 43 delayed) and 36 in the mandible (34 immediate and 2 delayed). For all 164 implants followed, the follow-up period ranged from 36 to 68 months (mean, 45.33 months). Eight implants failed and were consequently removed due to mobility after 12 months of loading, leading to a 4-year cumulative survival rate (CSR) of 95.1% (Table 1). All the failures occurred in the same patient and consisted in the loss of all the adjacent implants splinted together to complete a full-arch rehabilitation in the upper jaw.

The patient was a 61-year-old female, and the opposite denture was a full-arch tooth-supported fixed bridge. All the failed implants were placed in mature bone. As a consequence, for immediate implants, a survival rate of 100% was

(5)

achieved, whereas for delayed implants, the survival rate was 82.2% (P¼0.000).

The survival rate for the 128 maxillary implants was 93.8% and 100% for the 36 mandibular implants (P ¼ 0.125).

The 4-year survival rates of groups divided according to implant length (di- chotomized in,10 mm and.10 mm) were 74.2% and 100%, respectively (P ¼ 0.000). The 4-year survival rate of groups stratified according to implant diameter were 93.9% and 100% for diameter ,3.5 mm and for diameter .3.5 mm, respectively (P ¼ 0.155).

For implants placed in augmented sites, a survival rate of 91.8% was achieved, whereas for implants placed in pristine bone, it was 96.5% (P¼0.204). Figures 1 to 4 show different implant survival curves according to the Kaplan-Meier algorithm.

DISCUSSION

The majority of immediate implant loading studies reported similar success rates when compared to the traditional 2-stage approach.10–13,27–30 However, several factors may affect the outcome of immediate loading protocols. These could be divided into the following 4 categories: surgical, host, implant, and occlusion-related factors.31

Immediate loading of implants placed in postextraction sockets is a matter of current discussion because few reports have addressed this surgery- related factor. In some studies, immedi- ate implants are placed immediately after

the extraction of teeth presenting irre- versible endodontic and periodontal lesions, although the number of implants and the success rates obtained are not reported.20,31,32In a study by Pieri et al,33 implants placed immediately after tooth extraction were immediately loaded with a full-archfixed prosthesis, and the out- comes were clinically and radiographi- cally evaluated after 1 year of loading.

The high overall implant survival rate after 1 year (98.6%) and the limited mar- ginal bone changes encouraged the hy- pothesis that immediately loaded dental implants may be a predictable treatment modality when placed immediately after tooth removal. In a study of Degidi et al,34 388 implants were immediately loaded, of which 213 were inserted in healed bone and 175 in postextraction sockets.

At a 5-year follow-up, the overall sur- vival was 98%. No statistically signifi- cant differences were observed. In the present study, 164 implants were loaded within 48 hours after implant placement, of which 45 were inserted in healed bone and 119 in postextraction sockets. Over- all, only 8 implants failed and were con- sequently removed due to mobility after 12 months of loading, leading to a 4-year CSR of 95.1%. Surprisingly, all the failed implants were located in mature bone. As a consequence, for immediate implants, a survival rate of 100% was achieved, whereas for delayed implants, it was 82.2%. The difference between the groups was statistically significant. Con- sequently, the immediate loading of implants inserted in postextraction sites

could be considered a predictable clinical procedure.

It should be noted that host bone density plays a fundamental role in determining the success of immediate implant loading. It is well known that the mandible has better bone quality compared to the maxilla, and this is probably why the available documen- tation on immediate loading of implants mostly focused on completely edentulous mandibles. Interestingly, few investigations have shown similar predictability regardless of anatomical location.35,36In our study, we did not find statistically significant differences between mandible and maxilla, and we can conclude that the maxilla is also an appropriate site for immediate loading.

The survival rate for the 128 maxillary implants was 93.8% and 100% for the 36 mandibular implants. Within the limited available information, it seems that primary stability, more than the arch (anatomical) location, may be the fundamental requirement for immedi- ate implant loading techniques.

In this study, all implants attained primary stabilization at placement, regardless of the amount of alveolar bone. Additional supporting bone for the implants was attained by augmen- tation with an osteotome technique, engaging the thin cortical bone of the antral floor in the maxilla to obtain bicortical primary stabilization.

Forty-nine implants required such augmentative procedures and were inserted after simultaneous sinusfloor elevation with the osteotome tech- nique. For implants placed in aug- mented sites, a survival rate of 91.8%

was achieved, whereas for implants placed in pristine bone, it was 96.5%.

No statistically significant difference was found.

Implant design, surface texture, length, and diameter are relevant implant-related factors. As a general concept, threaded-type implants ensure higher mechanical retention and greater capability to bear compressive forces.37 The screw design enhances initial stabil- ity, which is the principal requirement for the success of immediate loading success. All the immediately loaded implants in the present study were screw shaped and had roughened surfaces, Table 1. Life Table Analysis for the Whole Number of Implants

Interval Time (mo)

Number of Implants

Number of Failed Implants

Survival Rate (%)

CSR (%)

0–6 164 0 100 100

612 164 0 100 100

1218 164 8 95.1 95.1

1824 156 0 100 95.1

2430 156 0 100 95.1

3036 156 0 100 95.1

3642 156 0 100 95.1

42–48 128 0 100 95.1

4854 68 0 100 95.1

5460 16 0 100 95.1

6066 8 0 100 95.1

.66 8 0 100 95.1

The life table examines the extent to which a specific event occurs across intervals of time. In the analysis presented here, time intervals correspond to follow-up periods. During each observation period, it is calculated the possibility that an event will occur for those implants that have yet to experience the event.

(6)

which allow faster osseointegration, greater bone-to-implant contact, and shorter healing times compared to machined surfaces.38–43

Implant length is another important factor that may also influence the out- come of immediate implant loading.

The majority of studies have suggested

that implants should be$10 mm long to ensure high success rates.18,27,44,45

Given that the data from these studies are based mainly on a clinical experi- ence with a limited patient cohort, the critical length and diameter of immedi- ately loaded implants remains to be fully determined. However, in the case of immediate implants, using implants with the longest possible length for immediate insertion after tooth extrac- tion was of great importance in achiev- ing implant engagement in basal bone apical to the socket. In the present investigation,fixtures were between 8 and 15 mm long and between 3.3 and 5.5 mm wide. The 4-year survival rates of groups divided according to implant length, dichotomized in,10 mm and .10 mm, were 74.2% and 100%, respectively, and the difference bet- ween the groups was statistically signif- icant. Degidi and Piattelli18 found a different survival rate according to specific cutoff points for implant diam- eters: large diameter implants had a worse trend compared to those of a smaller diameter. The authors con- cluded that this may be due to both the excessive depletion of trabecular bone from the implant site and the stress pat- terns related to increased implant surface area. Otherwise, the reason that wider diameter implants showed a poorer prog- nosis is probably related to an inverse correlation between the quality of bone and the implant diameter. The 4-year survival rates of groups stratified accord- ing to implant diameter in our sample were 93.9% and 100% for diameters of ,3.5 mm and.3.5 mm, respectively.

No statistically significant difference was found between these groups.

It was previously pointed out that immediate loading results for full-arch implant-supported restoration are dep- endent on factors such as occlusion, type of prosthesis, and the number implants.46 Controlling functional forces is one of the conditions for obtaining success of immediate implant loading. Oblique or horizontal forces applied during function are more detri- mental to implant stability compared to vertical forces. As a consequence, it is often suggested that patients with paraf- unctional habits should be excluded or at least well-informed about the

Fig. 1. Diagram illustrating the cumulative implant survival rate. Censored observations are indicated by the+marks.

Fig. 2. Survival of delayed versus immediate implants. Censored observations are indicated by the+marks (D, delayed implants; I, immediate implants).

(7)

potential risks associated when immedi- ate loading protocols are performed.31 In our study, bruxism was considered a contraindication for immediate

implant loading. As regards the pros- thetic design, when cross-arch implant splinting is performed, primary stability can be enhanced. Taking into account

these preliminary considerations, the positive results described in this present study can be attributed to the interaction of several favorable contributing fac- tors: the use of implants with the longest possible lengths, an immediate cross- arch splinting of the implants with a pas- sivelyfitting bar minimizing micromo- bility, and an even occlusal load distribution on a sufficient number of implants. In our study, each patient received 6 to 8 implants: in the upper jaw, the implants were distributed at sites 3, 5, 6, 8, 9, 11, 12, and 14, whereas in the mandible, they were distributed at sites 19, 21, 23, 26, 28, and 30.

Whenever possible, depending on the opposing dentition, the cross-arch implant-supported restoration was given a fully balanced occlusion and articulation with an equal spread of the load to all implants. Moreover, a brand new abutment shape was employed in the present experimenta- tion. Such abutments, having a specially designed screw joint and aflat bottom fitting with the head of thefixture, were preferred in the current application.

This is due to the fact that they apply uniform pressure around the entire radius of their planar surface extension under occlusal loading and because they are designed to be compressedflat and maintain their tension when abut- ment retaining screws are torqued.

Finally, it should be considered that the total number of failures occurred in a single patient and consisted in the loss of all the adjacent implants. We were unable to evaluate the causes of this distribution of the implant failures. The opposing denture in the patient con- cerned was a full-arch tooth-supported fixed prosthesis. It is reasonable to hypothesize that increased functional loads in the posterior quadrants may have represented an important factor, which resulted in implant failure.33Nev- ertheless, a similar cluster trend has been widely observed in implant fail- ures. Previous studies have examined thefinding that implant failures are not randomly distributed in the treated pop- ulation.47–49 Because failures tend to cluster within subjects, suggesting het- erogeneous risk among patient popula- tion, some authors developed and applied newer survival methodologies

Fig. 3. Distribution according to implant length. Censored observations are indicated by the

+marks (for length,10 mm and length.10 mm, respectively) (l, length).

Fig. 4. Distribution according to implant diameter. Censored observations are indicated by the+marks (for diameter,3.5 mm and diameter.3.5 mm, respectively) (Ø, diameter).

(8)

to adjust survival estimates for both within-subject clustering of observations and heterogeneous risk among subjects.

They found that risk for implant failure among subjects varied to a statistically significantly degree.50–52Actually, these findings indicate the presence of patient- related factors, which affect the survival of all implants within a given patient pop- ulation and may cause multiple implant failures. Occlusal factors, such as inade- quate adjustment of the prosthodontic appliance and overload, could play a role in this pattern behavior. Rather, in this individual, implant failure triggered a“domino”effect resulting in further im- plant failures, as previously reported.47 Such a phenomenon and its triggering causes should be the subject of further investigation.

CONCLUSION

In conclusion, the present report has shown that immediate occlusal loading of implants with full-archfixed restora- tions is a reliable surgical procedure, and it can be done successfully either in immediate extraction sites or in sound edentulous ridges. The overall success rate was high and appeared stable over time, regardless of anatomical location.

The use of implants with the longest possible length and favorable occlusal loads seemed to play a fundamental role for the success of this protocol. Finally, the beneficial contribution of an osseo- conductive implant surface should also be further investigated.

DISCLOSURE

The authors claim to have no financial interest, either directly or indirectly, in the products or informa- tion listed in the article.

REFERENCES

1. Lindquist LW, Carlsson GE, Jemt T.

A prospective 15-year follow-up study of mandibularxed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss.Clin Oral Implants Res. 1996;7:329336.

2. Astrand P, Ahlqvist J, Gunne J, et al.

Implant treatment of patients with edentu- lous jaws: a 20-year follow-up.Clin Implant Dent Relat Res. 2008;10:207217.

3. Fugazzotto PA, Gulbransen HJ, Wheeler SL, et al. The use of IMZ osseoin- tegrated implants in partially and com- pletely edentulous patients: success and failure rates of 2,023 implant cylinders up to 60+ months in function.Int J Oral Max- illofac Implants. 1993;8:617–621.

4. Branemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experi- ence from a 10-year period.Scand J Plast Reconstr Surg Suppl. 1977;16:1132.

5. Branemark PI, Adell R, Breine U, et al. Intra-osseous anchorage of dental prostheses. I. Experimental studies.Scand J Plast Reconstr Surg. 1969;3:81100.

6. Adell R, Lekholm U, Rockler B, et al.

A 15-year study of osseointegrated im- plants in the treatment of the edentulous jaw.Int J Oral Surg. 1981;10:387–416.

7. Cochran DL, Morton D, Weber HP.

Consensus statements and recommen- ded clinical procedures regarding loading protocols for endosseous dental implants.

Int J Oral Maxillofac Implants. 2004;19:

109113.

8. De Bruyn H, Van de Velde T, Collaert B. Immediate functional loading of TiOblast dental implants in full-arch edentulous mandibles: a 3-year prospective study.Clin Oral Implants Res. 2008;19:717–723.

9. Testori T, Meltzer A, Del Fabbro M, et al. Immediate occlusal loading of Os- seotite implants in the lower edentulous jaw. A multicenter prospective study.Clin Oral Implants Res. 2004;15:278284.

10. Maló P, Rangert B, Nobre M.All- on-Fourimmediate-function concept with Brånemark System implants for com- pletely edentulous mandibles: a retrospec- tive clinical study.Clin Implant Dent Relat Res. 2003;5:29.

11. Gallucci GO, Bernard JP, Bertosa M, et al. Immediate loading with xed screw-retained provisional restorations in edentulous jaws: the pickup technique.

Int J Oral Maxillofac Implants. 2004;19:

524533.

12. Collaert B, De Bruyn H. Immediate functional loading of TiOblast dental im- plants in full-arch edentulous maxillae:

a 3-year prospective study. Clin Oral Implants Res. 2008;19:12541260.

13. Testori T, Del Fabbro M, Capelli M, et al. Immediate occlusal loading and tilted implants for the rehabilitation of the atro- phic edentulous maxilla: 1-year interim results of a multicenter prospective study.

Clin Oral Implants Res. 2008;19:227232.

14. Brånemark P-I, Zarb GA, Albrektsson T.Tissue-Integrated Prosthe- ses: Osseointegration in Clinical Dentistry.

Chicago, IL: Quintessence; 1985:201–208.

15. Schwartz-Arad D, Laviv A, Levin L.

Survival of immediately provisionalized dental implants placed immediately into

fresh extraction sockets. J Periodontol.

2007;78:219223.

16. Crespi R, Cappareè P, Gherlone E, et al. Immediate occlusal loading of im- plants placed in fresh sockets after tooth extraction.Int J Oral Maxillofac Implants.

2007;22:955962.

17. De Bruyn H, Collaert B. Early load- ing of machined surface Brånemark implants in completely edentulous mandi- bles: healed bone versus fresh extraction sites.Clin Implant Dent Relat Res. 2002;4:

136142.

18. Degidi M, Piattelli A. Comparative analysis study of 702 dental implants sub- jected to immediate functional loading and immediate nonfunctional loading to tradi- tional healing periods with a follow-up of up to 24 months. Int J Oral Maxillofac Implants. 2005;20:99–107.

19. Grunder U. Immediate functional loading of immediate implants in edentu- lous arches: two-year results. Int J Periodontics Restorative Dent. 2001;21:

545551.

20. Cooper LF, Rahman A, Moriarty J, et al. Immediate mandibular rehabilitation with endosseous implants: simultaneous extraction, implant placement, and load- ing.Int J Oral Maxillofac Implants. 2002;

17:517525.

21. Balshi SF, Wolnger GJ, Balshi TJ.

A prospective study of immediate func- tional loading, following the Teeth in a Day protocol: a case series of 55 con- secutive edentulous maxillas.Clin Implant Dent Relat Res. 2005;7:2431.

22. Balshi TJ, Wolnger GJ. Teeth in a day for the maxilla and mandible: case report.Clin Implant Dent Relat Res. 2003;

5:11–16.

23. Balshi TJ, Wolfinger GJ. Teeth in a day.Implant Dent. 2001;10:231233.

24. Cawood JI, Howell RA. A classifi- cation of the edentulous jaws. Int J Oral Maxillofac Surg. 1988;17:232236.

25. Barone A, Cornelini R, Ciaglia R, et al. Implant placement in fresh extraction sockets and simultaneous osteotome sinus oor elevation: a case series.Int J Periodon- tics Restorative Dent. 2008;28:283289.

26. Singh R, Mukhopadhyay K. Sur- vival analysis in clinical trials: Basics and must know areas. Perspect Clin Res.

2011;2:145148.

27. Chiapasco M, Gatti C, Rossi E, et al. Implant-retained mandibular over- dentures with immediate loading. A retro- spective multicenter study on 226 consecutive cases. Clin Oral Implants Res. 1997;8:4857.

28. Gatti C, Haeiger W, Chiapasco M.

Implant-retained mandibular overdentures with immediate loading: a prospective study of ITI implants.Int J Oral Maxillofac Implants. 2000;15:383388.

(9)

29. Sennerby L, Gottlow J. Clinical outcomes of immediate/early loading of dental implants. A literature review of re- cent controlled prospective clinical studies.

Aust Dent J. 2008;53:8288.

30. Ganeles J, Zöllner A, Jackowski J, et al. Immediate and early loading of Straumann implants with a chemically modied surface (SLActive) in the poste- rior mandible and maxilla: 1-year results from a prospective multicenter study. Clin Oral Implants Res. 2008;19:

11191128.

31. Gapski R, Wang H-L,

Mascarenhas P, et al. Critical review of im- mediate implant loading. Clin Oral Impl Res. 2003;14:515527.

32. Wolnger G, Balshi T, Rangert B.

Immediate functional loading of Brånemark system implants in edentulous mandibles:

clinical report of results of developmental and simplified protocols.Int J Oral Maxillo- fac Implants. 2003;18:250–257.

33. Pieri F, Aldini NN, Fini M, et al. Im- mediate occlusal loading of immediately placed implants supportingxed restora- tions in completely edentulous arches: a 1- year prospective pilot study.J Periodontol.

2009;80:411421.

34. Degidi M, Piattelli A, Felice P, et al.

Immediate functional loading of edentulous maxilla: a 5-year retrospective study of 388 titanium implants. J Periodontol.

2005;76:10161024.

35. Capelli M, Zuffetti F, Del Fabbro M, et al. Immediate rehabilitation of the completely edentulous jaw withxed pros- theses supported by either upright or tilted implants: a multicenter clinical study.

Int J Oral Maxillofac Implants. 2007;22:

639–644.

36. Perry J, Lenchewski E. Clinical per- formance and 5-year retrospective evalua- tion of Frialit-2 implants. Int J Oral Maxillofac Implants. 2004;19:887–891.

37. Misch CE. Implant design consid- erations for the posterior regions of the mouth.Implant Dent. 1999;8:376386.

38. Grassi S, Piattelli A, de Figueiredo LC, et al. Histologic evaluation of early human bone response to different im- plant surfaces. J Periodontol. 2006;77:

17361743.

39. Cochran D, Oates T, Morton D, et al. Clinicaleld trial examining an implant with a sand-blasted, acid-etched surface.

J Periodontol. 2007;78:974982.

40. Cochran DL. A comparison of en- dosseous dental implant surfaces.

J Periodontol. 1999;70:2339.

41. Yang GL, He FM, Yang XF, et al.

Bone responses to titanium implants sur- face-roughened by sandblasted and dou- ble etched treatments in a rabbit model.

Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;106:516524.

42. Maló P, Nobre Mde A, Petersson U, et al. A pilot study of complete edentu- lous rehabilitation with immediate function using a new implant design: case series.

Clin Implant Dent Relat Res. 2006;8:223 232.

43. Marin C, Granato R, Suzuki M, et al.

Removal torque and histomorphometric evaluation of bioceramic grit-blasted/

acid-etched and dual acid-etched implant surfaces: an experimental study in dogs.

J Periodontol. 2008;79:19421949.

44. Tarnow DP, Emtiaz S, Classi A.

Immediate loading of threaded implants at stage 1 surgery in edentulous arches:

ten consecutive case reports with 1- to

5-year data.Int J Oral Maxillofac Implants.

1997;12:319–324.

45. Horiuchi K, Uchida H, Yamamoto K, et al. Immediate loading of Brånemark system implants following placement in edentulous patients: a clinical report. Int J Oral Maxillofac Implants. 2000;15:

824830.

46. Chiapasco M. Early and imme- diate restoration and loading of implants in completely edentulous patients. Int J Oral Maxillofac Implants. 2004;19:

7691.

47. Schwartz-Arad D, Laviv A, Levin L.

Failure causes, timing, and cluster behav- ior: an 8-year study of dental implants.

Implant Dent. 2008;17:200207.

48. Weyant RJ, Burt BA. An assess- ment of survival rates and within-patient clustering of failures for endosseous oral implants.J Dent Res. 1993;72:2–8.

49. Ekfeldt A, Christiansson U, Eriksson T, et al. A retrospective analysis of factors associated with multiple implant failures in maxillae. Clin Oral Impl Res.

2001;12:462467.

50. Haas R, Mensdorff-Pouilly N, Mailath G, et al. Survival of 1,920 IMZ im- plants followed for up to 100 months.Int J Oral Maxillofac Implants. 1996;11:581 588.

51. Lekholm U, Gunne J, Henry P, et al. Survival of the Brånemark implant in partially edentulous jaws: a 10-year prospective multicenter study. Int J Oral Maxillofac Implants. 1999;14:639645.

52. Chuang SK, Wei LJ, Douglass CW, et al. Risk factors for dental implant failure:

a strategy for the analysis of clustered fail- ure-time observations.J Dent Res. 2002;

81;572–577.

Références

Documents relatifs

The results obtained from the present and other clinical investigations may lead to the assumption that immediate provisional restoration of one-piece implants placed in healed bone

Objective: The aim of this study was to assess the influence of patient characteristics on edentulous subjects’ preferences for different prosthodontic treatments with

The aims of this longitudinal prospective case series study were (1) to determine the survival rate of 10 four-unit fixed dental pros- theses supported by 20 anterior maxillary

Many different techniques analyzing the accuracy of IOS have been reported; however, using reference scan data from an industrial high-precision scanner is still regarded as the

In this paper we are concerned with the normal form of a completely integrable Hamiltonian system near an equilibrium point.. hn are

The primary objective of the present study was to evaluate and compare the clinical out- comes for implants placed with a high insertion torque (50–100 N cm) and a regular insertion

The patients were randomly assigned to either the test group (zirconia frameworks veneered with pressed ceramic; IPS e.max ZirPress, Ivoclar Vivadent AG, Schaan, Liechtenstein; n =

Keywords: free‐handed; flapless surgery; mini dental implants; CBCT evaluation; surgical complications; maxillary