Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants - a five-year case series

MORAGUEZ, Osvaldo, et al.

Abstract

To determine the survival rate of 10 four-unit fixed dental prostheses (FDPs) replacing the four maxillary incisors, supported by 20 narrow-diameter implants (NDIs), (2) to assess the incidence of mechanical and biological complications, and (3) to evaluate bone level changes longitudinally after final FDP insertion

MORAGUEZ, Osvaldo, et al . Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants - a five-year case series. Clinical Oral Implants Research , 2017, vol. 28, no. 7, p. 887-892

DOI : 10.1111/clr.12895 PMID : 27325154

Available at:

http://archive-ouverte.unige.ch/unige:89036

Disclaimer: layout of this document may differ from the published version.

(2)

Francesca Vailati Linda Gr utter € Irena Sailer Urs C. Belser

Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants – a five-year case series

Authors’ affiliation:

Osvaldo Moraguez, Francesca Vailati, Linda Gr€utter, Irena Sailer, Urs C. Belser,Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland

Corresponding author:

Osvaldo Moraguez

Division of Fixed Prosthodontics and Biomaterials, University Clinics of Dental Medicine, University of Geneva, Rue Barthelemy-Menn 19, Geneva 1205, Switzerland

Tel.: +41 22 379 4092 Fax: +41 22 379 4052

e-mail: [email protected]

Key words: case series, clinical study, esthetics, implant-supported fixed dental prostheses, maxillary incisors, narrow-diameter implants

Abstract

Objectives: (1) To determine the survival rate of 10 four-unit fixed dental prostheses (FDPs) replacing the four maxillary incisors, supported by 20 narrow-diameter implants (NDIs), (2) to assess the incidence of mechanical and biological complications, and (3) to evaluate bone level changes longitudinally after final FDP insertion.

Materials and methods: Ten patients (six women, four men), mean age 49.412.6 years, were treated with a four-unit anterior maxillary FDP (six screw-retained; four cemented). Biological parameters, eventual technical complications, radiographic measurements, and study casts were assessed at 1 (baseline), 3, and 5 years after implant placement. A multilevel logistic regression test was performed on clinical parameters and bone level changes (significance levelP<0.05).

Results: The 5-year implant and FDP survival rate was 100%. Mean modified plaque index (mPI) values were 0.03 and 0.02 at 3 and 5 years, significantly lower when compared to mPI (0.110.31) at 1 year. Mean modified sulcus bleeding index (mSBI) was 0.08, 0.08, and 0.15 over time. Probing depth (PD) values were 1.57, 1.64, and 2.03 mm. Statistically significant differences were found between 1 vs. 5 year (P=0.0003) and 3 vs. 5 year (P=0.001). Keratinized mucosa (3.65 mm) remained stable during observation period. DIB mean values were 2.010.34, 2.130.13, and 2.170.38 mm. Patient satisfaction based on visual analog scale revealed favorable fulfillment of overall treatment and esthetic expectations.

Conclusions: Two NDIs supporting a four-unit FDP to replace the four missing maxillary incisors may be considered a predictable treatment modality.

The replacement of the four maxillary incisors by means of an implant-supported prosthesis is challenging from an esthetic and biome- chanical point of view (Vailati & Belser 2007).

In contrast to the long-term studies related to esthetic single-tooth replacement (Buser et al.

2013a; Chappuis et al. 2015), little has been reported on implant-supported multiunit fixed dental prostheses (FDPs)(Zarb & Zarb 2002;

Krennmair et al. 2011). Open questions focus on the ideal number, dimension, and localiza- tion of the implants (Vailati & Belser 2007;

Krennmair et al. 2011), because reports in the literature are inconclusive on their esthetic outcomes, particularly with respect to the interimplant soft tissue contours (Belser et al.

2004a; Mitrani et al. 2005).

Different treatment alternatives were first described in detail by Vailati and Belser (Vai- lati & Belser 2007). These authors stated that

consecutive single-implant rehabilitation of the four maxillary incisors is limited by ana- tomic parameters, with the notable disadvan- tage that the small interimplant distances (Tarnow et al. 2000; Belser et al. 2004a) may increase both marginal bone resorption and loss of papilla (Tarnow et al. 1992; Choquet et al. 2001; Martin et al. 2007; Chen & Buser 2012). The currently recommended strategy is to limit the number of implants, to avoid adja- cent implants, and to position the implants next to natural teeth to benefit from tissue support provided by these structures (Belser et al. 2004b). This clinical concept, based on a biological-prosthetic approach, has been pri- marily derived from clinical experience and prosthodontic principles, rather than from for- mal scientific evidence.

One possible option proposed by Vailati and Belser (Vailati & Belser 2007) is the Date:

Accepted 7 May 2016 To cite this article:

Moraguez O, Vailati F, Gr€utter L, Sailer I, Belser UC. Four- unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implantsa five-year case series.

Clin. Oral Impl. Res.00, 2016, 1–6.

doi: 10.1111/clr.12895

(3)

insertion of two narrow-diameter implants (NDIs) at the lateral incisor sites to support a four-unit FDP, comprising two central ovate pontics. In the described context, NDIs placed in the position of the lateral incisors offer both a distinct biological and an esthetic advantage, due to their small dimen- sion. They allow to respect the minimal interproximal distance (i.e., 1.5 mm) to the adjacent natural canines without interfering with the future embrasure between the lat- eral incisor implant crown and the central incisor pontic. Although the NDI was origi- nally designed for small single-tooth gaps (Buser et al. 2000; Romeo et al. 2006), it was progressively used to support multiunit FDPs replacing the maxillary and mandibular inci- sors (Cordaro et al. 2006), especially in patients with high esthetic expectations.

However, clinical data using this type of implants to support multiunit FDPs in case of extended edentulous spaces in the anterior maxilla are still scarce.

The aims of this longitudinal prospective case series study were (1) to determine the survival rate of 10 four-unit fixed dental pros- theses supported by 20 anterior maxillary NDIs through a clinical observation time of 5 years, (2) to assess the incidence of mechan- ical and biological complications, and (3) to evaluate peri-implant bone level changes lon- gitudinally after final FDP insertion.

Materials and methods

Study design

This case series was performed at the Divi- sion of Fixed Prosthodontics and Biomateri- als, University Clinics of Dental Medicine, University of Geneva, as part of a doctoral thesis (Moraguez 2015). Ten patients restored with a four-unit anterior maxillary FDP par- ticipated in this prospective study. The patient’s history before implant placement included failing tooth-borne conventional fixed restorations that needed replacement.

The study protocol was approved by the Human Research Ethics Commission of the University Hospitals of Geneva (Ref. 14-006).

Informed consent was obtained from all patients prior to their inclusion into the study.

The patients (six female and four male) with a mean age of 49.412.6 years (range 32–68 years) were treated with 10 metal–ce- ramic FDPs replacing the four maxillary inci- sors. Among these, nine prostheses were supported by 18 tissue-level NDIs (narrow neck implants: 3.5–∅ 3.3 mm; Straumann

Institute, Basel, Switzerland) and one by two tissue-level NDIs (regular neck 4.8–∅

3.3 mm; Straumann Institute, Basel, Switzer- land) inserted at the sites of the lateral inci- sors. Eighteen implants (8 of 10 mm length;

10 of 12 mm length) were placed according to the concept of early implant placement (including five with simultaneous facial con- tour augmentation), while two implants (12 mm length) were placed using a delayed approach. All implants were loaded following a conventional protocol. After a provisional phase (6–9 months), six screw-retained mul- tiunit FDPs (torqued to 35 Ncm) and four cemented multiunit FDPs (temporary cement; Temp-Bond, Kerr) were inserted. To avoid cement excess in the peri-implant tis- sues, dental floss (Johnson & Johnson Reach Dental Floss,) was used between interproxi- mal contact points, and below ovoid pontics (Oral-B Super Floss). Eight patients were non- smokers and two patients were light smokers (<10 cigarettes/day).

Clinical examination

The clinical examination was performed 1 (baseline), 3, and 5 years after implant sur- gery. Eventual technical complications (chip- ping of the ceramic, screw loosening, loss of retention) were recorded, and analysis of bio- logical parameters was performed as indi- cated in detail below. In addition, radiographic evaluation and cast analysis were carried out at the time intervals. To standardize clinical and radiographic mea- surements by one examiner (OM), the base- line was established at 1 year after implant placement. FDPs were not removed at any time between the points of evaluation.

Biological parameters

Modified plaque index (mPI), modified sulcus bleeding index (mSBI), and probing depth (PD in mm) at six aspects around the implants (Mombelli et al. 1987) were assessed. In addi- tion, the width of the facial keratinized mucosa (KM) was measured on the mid-facial aspect of each implant (in mm).

Radiographic examination

Standardized periapical radiographs were taken at 1, 3, and 5 years using silicone bite blocks. The radiographic linear distance from the implant shoulder to the first bone-to- implant contact (DIB) was used to calculate the marginal bone levels at the mesial and dis- tal sites of the implants. For each implant and examination interval, the DIB value was cal- culated as the average of the obtained mesial and distal values (Weber et al. 1992). These measurements were obtained using the ImageJ 1.48v program (Wayne Rasband National Institutes of Health, USA). The digitized images were calibrated by setting the scale to the known distance between two implant threads (1 mm) (Fig. 1). The radiographic read- ings were performed by one calibrated exam- iner who was not involved in the surgical or prosthetic treatment of the patients. In addi- tion, a frequency analysis of the difference between DIB values from the 1-, 3-, and 5-year examination was performed (DDIB1toDDIB5) (Buser et al. 1999). A negativeDDIB indicated bone loss between two examinations.

Cast analysis

Impressions were taken at 1, 3, and 5 years to produce study casts of the maxilla. The mid-facial height of each implant crown (IC)

Fig. 1. DIB (Distance between Implant shoulder and first interproximal Bone-to-implant contact). Landmarks of the radiographic measurements: implant shoulder (yellow line); DIB (red line); reference measurement (1 mm between implant threads).

Moraguez et al. Anterior maxillary fixed dental prostheses based on two narrow-diameter implants

(4)

was measured to identify potential changes in clinical crown height or mucosal recession between time intervals.

Patient satisfaction based on questionnaire and related visual analog scale

Patient satisfaction was assessed using a 100- mm visual analog scale (VAS). The patients were asked to answer two questions by draw- ing a vertical mark on a horizontal line to indicate the esthetic and overall treatment satisfaction at the first recall examination.

The scale varied from 0 (very unsatisfied) to 10 (very satisfied) on the following questions:

“Did the final esthetic result correspond to your initial expectations?” and “How do you evaluate the overall treatment result ?”

Data analysis

To analyze all parameters measured at 1, 3, and 5 years after implant surgery, multilevel logistic regression for binary variables (mPI) and multilevel regression for continuous vari- ables (PD) were used. The multilevel model techniques were chosen to account for the non-independence of the data, namely that data stemming from sites of the same implant are more similar than data from dif- ferent implants, and data from implants of the same patient are more similar than data from different patients. Technically, a ran- dom intercept was included at the patient level in the multilevel models. Conditions of applications, including conditional normality, were checked using residual plots. Patient satisfaction parameters were expressed using mean values (standard deviation). All anal- yses were performed using R v3.1.0 program (R Foundation for Statistical Computing, Vienna, Austria), and the confidence level was 95% (P<0.05).

Results

All ten patients recruited attended the 1- (baseline), 3-, and 5-year follow-up

examinations. The 5-year survival rate of the 10 examined four-unit FDPs and 20 NDIs was 100%. None of the FDPs presented bio- logical or technical complications such as chipping of the ceramic, loosening of the screw/abutment, loss of retention, or failure between the first and fifth year.

Biological outcomes

Detailed results of peri-implant soft tissue parameters are listed in Table 1. All implants were still firmly integrated, without suppura- tion in the peri-implant sulcus. The patients exhibited very good oral hygiene with mean mPI values of 0.03 and 0.02 at the 3- and 5- year examination, respectively. These results showed statistically significant differences compared to the mean mPI value (0.110.31) obtained at the 1-year follow- up. The peri-implant soft tissues appeared clinically healthy with little tendency to bleed after probing. The mean mSBI were 0.08, 0.08, and 0.15 at the 1-, 3-, and 5-year follow-ups, showing no significant difference between examinations. The mean PD was 1.57 mm at the 1-year examination. These values slightly increased to 1.64 and 2.03 mm during the follow-up period. The mean PD values were statistically different between the 1- vs. 5-year (P = 0.0003) and 3- vs. 5-year examination (P = 0.001). The mean KM value at the 5-year follow-up was 3.65 mm, showing a stable and wide band of KM on the facial aspect of the implant crowns. There were no differences between the 3- and 5-year follow-ups.

Radiographic bone level outcomes

The radiographs obtained of each implant did not reveal any signs of continuous peri- implant radiolucency during the entire obser- vation period (Fig. 2).

The mean DIB value (Table 2) after 1 year was 2.010.34, 2.130.13 mm (range 1.75–2.8 mm) after 3 years, and 2.170.38 mm (range 1.65–3.05 mm) after 5 years. The

differences between the mean DIB values for the three time points analyzed were not sta- tistically significant (DIB 1–3 year: P = 0.12;

DIB 1–5 year: P = 0.06; DIB 3–5 year:

P = 0.31). The frequency analysis of the 20 implants evaluated between the 1- and 3-year follow-up (D DIB 1–3 year) showed that all the implants exhibited either a slight bone gain or bone loss between +0.50 and 0.74 mm (Fig. 3). Similar results were found between the 1- and 5-year examination (D DIB 1–5 year) within+0.75 and 0.75 mm of bone gain or loss. The maximum bone loss was 0.75 mm for one implant (Fig. 4).

Cast analyses

Clinical implant crown height values remained stable over 5 years. The mean IC values were 13.06 mm (SD 1.83 mm), 12.49 mm (SD 3.09 mm), and 13.96 mm (SD 1.90 mm) at the three time points (Table 3).

The differences between IC values of the three examinations were not statistically sig- nificant (IC 1–3 year: P = 0.74; IC 1–5 year:

P = 0.95; IC 3–5 year: P = 0.82). The mean distance measured between the mesial sur- faces of the canines was 35.35 mm (SD 1.96 mm; range 32.5–39.5 mm).

Patient satisfaction

The patient feedback based on VAS analyses revealed an overall treatment satisfaction of 96.9% (SD 0.51), and an esthetic satisfaction of 92.7% (SD 0.96).

Discussion

The results of this prospective case series indicate that the use of two NDIs placed at the lateral sites may be sufficient to support a four-unit FDP as a predictable modality to replace four missing maxillary incisors. The examined implants maintained successful tis- sue integration during the entire 5-year examination period as documented by both biological and radiographic parameters.

The standard soft tissue parameters mPI, mSBI, PD as well as KM values revealed healthy peri-implant soft tissues. Patients showed significant improvement in plaque control at the 3- and 5-year follow-up, com- pared to the 1-year examination. Concerning PD values, the measurements slightly increased from the 1-year follow-up, showing some differences at the 3- and 5-year exami- nation. None of the other parameters showed statistically significant differences over time.

The mean values obtained are in accordance with data from long-term studies evaluating Table 1. Biological outcomes of the 20 implants (meanSD; range)

Examination mPI mSBI PD (mm) KM (mm)

1 year 0.110.31ab 0.080.28 1.570.66a (P= 0.0003) 3.401.31

median 0 0 1 4

range 0–0.33 0–0.58 1.08–2.33 1.0–5.5

3 years 0.030.18a (P= 0.03) 0.080.28 1.640.71b (P= 0.001) 3.501.15

median 0 0 2 4

range 0–0.16 0–0.33 1.17–2.42 2.0–5.5

5 years 0.020.13b (P= 0.01) 0.150.36 2.030.92ab 3.651.23

median 0 0 2 4

range 0–0.08 0–0.58 1.25–3.08 2.0–5.5

Statistically significant differences between the gingival parameter scores are marked with the same letters. mPI, modified plaque index; mSBI, modified sulcus bleeding index; PD, probing depth; KM, keratinized mucosa.

(5)

bone-level (Buser et al. 2011; 2013a; Sanz et al. 2015) and tissue-level (Buser et al.

2013b) implants supporting single crowns in the esthetic zone.

Clinical long-term data on anterior maxil- lary implant-retained FDPs are scarce. The clinical data published by Krennmair et al.

(Krennmair et al. 2011) in a retrospective study using two standard diameter implants to replace the four maxillary incisors are in line with the mean clinical values obtained in this study.

The DIB values obtained from the 20 implants indicated overall stable peri-implant

bone crest levels on the mesial and distal aspects. As stated in previous studies (Buser et al. 2013b; 1999), mean DIB values alone are not indicative of the stability of peri-implant bone crest levels, because some implants will lose or gain bone over time. Thus, frequency analyses of D DIB values were calculated between 1-, 3-, and 5-year examinations. In the present study, all of the implants exhibited either a slight bone gain or loss within 0.75 and 0.75 mm. These results are in line with previous studies presenting a frequency analy- sis of D DIB values (Bornstein et al. 2005;

Buser et al. 2013b; 1999). The favorable clini- cal and radiographic results were also con- firmed by the cast analyses.

Concerning patient satisfaction, it would be essential to create a white and pink esthetic index for multiunit implant recon- structions that allows the assessment of esthetic outcomes with objective parameters (Benic et al. 2012). Such an “objective” analy- sis, correlated with the “subjective” evalua- tion of the patient, would help clinicians to identify parameters that make restorations more esthetically pleasing for the patient (Annibali et al. 2012).

Different treatment options for the replace- ment of the four maxillary incisors with an implant-supported FDP were first discussed by Vailati and Belser (Vailati & Belser 2007), including the proposal to routinely use only two NDIs positioned at the lateral incisor sites. However, only case reports (Vela-Nebot et al. 2011; Petropoulou et al. 2013) and a Fig. 2. Patients 2 and 10 with screw-retained fixed dental prostheses at 5-year follow-up.

Table 2. Radiographic bone level outcomes of the 20 implants (DIB; mm)

Examination period

1 year 3 years 5 years

Mean 2.01 2.13 2.17

SD 0.34 0.30 0.38

Median 2.00 2.08 2.20

Minimum 1.50 1.75 1.65

Maximum 2.70 2.80 3.05

No statistically significant differences among DIB (distance from the implant shoulder to the first bone-to-implant contact) values were found over the course of 5 years (DIB 1–

3 year:P = 0.12; DIB 1–5 year:P = 0.06; DIB 3 –5 year:P = 0.31).

Fig. 3. Frequency analysis ofD DIB 13 year (in mm). A negative value reveals bone loss between the time intervals.

Moraguez et al. Anterior maxillary fixed dental prostheses based on two narrow-diameter implants

(6)

retrospective study (Krennmair et al. 2011) have been published on this subject since those recommendations were made.

This case series has certain limitations. To standardize all measurements, the baseline was not established at implant placement or FDP delivery, but started at the 1-year fol- low-up examination. The period between final insertion and 1-year follow-up ranged only between 1–4 months. Nevertheless, no biological or technical complications were detected during this interval. As the FPDs were not removed at any time between the points of evaluation, no method to evaluate implant mobility was required.

This study examined 10 patients where two NDIs were used at the lateral incisor sites to support an FDP replacing the four maxillary incisors. The occlusal analysis revealed an overjet that varied between 2 and 7 mm (mean 3.9 mm), and an overbite between 2 and 6 mm (mean 3.2 mm). Fur- thermore, three patients presented bilateral canine guidance, six patients showed bilat- eral group function, whereas one patient exhibited a right canine guidance and left group function. Although reasonable con- cerns have been raised about the lower mechanical strength of the NDI (Schwarz 2000; Zinsli et al. 2004), particularly in case of non-ideal occlusal schemes, no mechanical complications or failures were observed in this 5-year clinical study. These results are in agreement with recent reviews (Klein et al. 2014) that concluded that survival rates of NDIs appear to be similar compared to those of regular-diameter implants. More- over, clinical studies including NDIs with a new titanium–zirconium alloy (TiZr) (Barter et al. 2012; Ioannidis et al. 2015) have shown promising results that point to an incremen- tal gain in the mechanical properties of this type of implants. Further, in patients with high esthetic expectations and limited

horizontal bone volume, NDIs seem to be a choice with a predictable long-lasting biologi- cal result.

Conclusions

The 5-year survival rate of both the examined 4-unit anterior metal–ceramic FDPs and the supporting implants was 100%.

The clinical and radiographic parameters of all 20 implants remained stable throughout the observation period.

No technical complications were registered during the entire study duration.

The investigated treatment approach in gen- eral and the esthetic outcome in particular were favorably perceived, as expressed by a high degree of patient satisfaction.

Within the limitations of this prospective case series study, two soft tissue-level NDIs supporting a four-unit FDP to replace the four missing maxillary incisors may be con- sidered a predictable treatment modality, including the potential of becoming the treat- ment of choice. However, additional well- controlled clinical studies based on larger patient populations are needed to confirm these favorable data.

Acknowledgements:

Our gratitude is expressed to Professors Daniel Buser and Jean- Pierre Bernard for their surgical contribution in this study and Dr. Pierre Guex for the surgical and prosthetic procedures in two of the cases presented. Statistical analysis was provided by the Clinical Research Center, University of Geneva and Geneva University Hospitals (Delphine Courvoisier). This study was presented on November 7, 2015, during the SSOI Research Award competition held in Lausanne, Switzerland.

Conflict of interests

The authors declare no conflict of interest related to the study.

References

Annibali, S., Bignozzi, I., La Monaca, G. & Cristalli, M.P. (2012) Usefulness of the aesthetic result as a success criterion for implant therapy: a review.

Clinical Implant Dentistry & Related Research 14: 3–40.

Barter, S., Stone, P. & Bragger, U. (2012) A pilot study to evaluate the success and survival rate

of titanium-zirconium implants in partially edentulous patients: results after 24 months of follow-up. Clinical Oral Implants Research 23: 873–881.

Belser, U., Buser, D. & Higginbottom, F. (2004b) Consensus statements and recommended clini- cal procedures regarding esthetics in implant

dentistry. The International Journal of Oral &

Maxillofacial Implants19(Suppl): 73–74.

Belser, U.C., Schmid, B., Higginbottom, F. & Buser, D. (2004a) Outcome analysis of implant restora- tions located in the anterior maxilla: a review of the recent literature.The International Journal of Oral & Maxillofacial Implants19(Suppl): 30–42.

Fig. 4. Frequency analysis ofD DIB 1–5 year (in mm). A negative value reveals bone loss between the time intervals.

Table 3. Cast analysis regarding the height of the 20 implant crowns (mm; SD)

Examination

period IC (mm)

DIC (vs. 1-year examination)

1 year 13.061.83 –

Median 12.80 –

3 years 12.493.09 0.582.23

Median 12.65 0

5 years 13.961.90 0.110.39

Median 12.55 0

No statistically significant differences among IC length values were found over the course of 5 years (IC 1–3 year:P = 0.74; IC 1–5 year:

P = 0.95; IC 3–5 year:P = 0.82).

(7)

Benic, G.I., Wolleb, K., Sancho-Puchades, M. &

Hammerle, C.H. (2012) Systematic review of parameters and methods for the professional assessment of aesthetics in dental implant research. Journal of Clinical Periodontology 39 (Suppl 12): 160–192.

Bornstein, M.M., Schmid, B., Belser, U.C., Lussi, A.

& Buser, D. (2005) Early loading of non-sub- merged titanium implants with a sandblasted and acid-etched surface. 5-year results of a prospective study in partially edentulous patients. Clinical Oral Implants Research16: 631–638.

Buser, D., Chappuis, V., Bornstein, M.M., Wit- tneben, J.G., Frei, M. & Belser, U.C. (2013b) Long-term stability of contour augmentation with early implant placement following single tooth extraction in the esthetic zone: a prospective, cross-sectional study in 41 patients with a 5- to 9-year follow-up. Journal of Periodontology 84: 1517–1527.

Buser, D., Chappuis, V., Kuchler, U., Bornstein, M.M., Wittneben, J.G., Buser, R., Cavusoglu, Y.

& Belser, U.C. (2013a) Long-term stability of early implant placement with contour augmenta- tion.Journal of Dental Research92: 176S–182S.

Buser, D., Mericske-Stern, R., Dula, K. & Lang, N.P. (1999) Clinical experience with one-stage, non-submerged dental implants. Advances in Dental Research13: 153–161.

Buser, D., von Arx, T., ten Bruggenkate, C. & Wein- gart, D. (2000) Basic surgical principles with iti implants. Clinical Oral Implants Research 11 (Suppl 1): 59–68.

Buser, D., Wittneben, J., Bornstein, M.M., Grutter, L., Chappuis, V. & Belser, U.C. (2011) Stability of contour augmentation and esthetic outcomes of implant-supported single crowns in the esthetic zone: 3-year results of a prospective study with early implant placement postextraction. Journal of Periodontolology82: 342–349.

Chappuis, V., Bornstein, M.M., Buser, D. & Belser, U. (2015) Influence of implant neck design on facial bone crest dimensions in the esthetic zone analyzed by cone beam CT: a comparative study with a 5-to-9-year follow-up. Clinical Oral Implants Research1–12. doi:10.1111/clr.12692.

Chen, S. & Buser, D. (2012) Surgical Considerations and Treatment Procedures for Extended Edentu- lous Spaces in the Esthetic Zone. In: Wismeijer, D., Chen, S. & Buser, D., eds. ITI Treatment Guide: Extended Edentulous Spaces in the Esthetic Zone, Vol.6, 43–64. Berlin: Quintessence.

Choquet, V., Hermans, M., Adriaenssens, P., Daele- mans, P., Tarnow, D.P. & Malevez, C. (2001)

Clinical and radiographic evaluation of the papilla level adjacent to single-tooth dental implants. A retrospective study in the maxillary anterior region.Journal Periodontoly72: 1364–1371.

Cordaro, L., Torsello, F., Mirisola Di Torresanto, V.

& Rossini, C. (2006) Retrospective evaluation of mandibular incisor replacement with narrow neck implants. Clinical Oral Implants Research 17: 730–735.

Ioannidis, A., Gallucci, G.O., Jung, R.E., Borzangy, S., Hammerle, C.H. & Benic, G.I. (2015) Tita- nium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premo- lar single crowns: 3-year results of a randomized controlled clinical study.Journal of Clinical Peri- odontology42: 1060–1070.

Klein, M.O., Schiegnitz, E. & Al-Nawas, B. (2014) Systematic review on success of narrow-dia- meter dental implants. The International Jour- nal of Oral & Maxillofacial Implants 29(Suppl):

43–54.

Krennmair, G., Seemann, R., Weinlander, M., Wegscheider, W. & Piehslinger, E. (2011) Implant- prosthodontic rehabilitation of anterior partial edentulism: a clinical review.The International Journal of Oral & Maxillofacial Implants 26: 1043–1050.

Martin, W.C., Morton, D. & Buser, D. (2007) Pre- operative Analysis and Prosthetic Treatment Planning in Esthetic Implant Dentsitry. In: Buser, D., Belser, U.C & Wismeijer, D. eds. ITI Treat- ment Guide: Implant Therapy in the Esthetic Zone—Single-Tooth Replacements, Volume 1, p.

9–24. Berlin: Quintessence.

Mitrani, R., Adolfi, D. & Tacher, S. (2005) Adjacent implant-supported restorations in the esthetic zone: understanding the biology. Journal of Esthetic and Restorative Dentistry17: 211–222;

discussion 222–223

Mombelli, A., van Oosten, M.A., Schurch, E., Jr &

Land, N.P. (1987) The microbiota associated with successful or failing osseointegrated titanium implants.Oral Microbiology and Immunology2: 145–151.

Moraguez, O. (2015) Ponts fixes remplacßant les qua- tre incisives maxillaires soutenus par deux implants a diametreetroit– etude pilote sur 5 ans. These Doctorat en Medecine Dentaire, Fac- ulte de Medecine, Universite de Geneve.

Petropoulou, A., Pappa, E. & Pelekanos, S. (2013) Esthetic considerations when replacing missing maxillary incisors with implants: a clinical report.Journal of Prosthetic Dentistry109: 140– 144.

Romeo, E., Lops, D., Amorfini, L., Chiapasco, M., Ghisolfi, M. & Vogel, G. (2006) Clinical and radiographic evaluation of small-diameter (3.3- mm) implants followed for 1–7 years: a longitudi- nal study. Clinical Oral Implants Research 17: 139–148.

Sanz, M., Ivanoff, C.J., Weingart, D., Wiltfang, J., Gahlert, M., Cordaro, L., Ganeles, J., Bragger, U., Jackowski, J., Martin, W.C., Jung, R.E., Chen, S.

& Hammerle, C. (2015) Clinical and radiologic outcomes after submerged and transmucosal implant placement with two-piece implants in the anterior maxilla and mandible: 3-year results of a randomized controlled clinical trial.Clinical Implant Dentistry & Related Research17: 234– 246.

Schwarz, M.S. (2000) Mechanical complications of dental implants.Clinical Oral Implants Research 11(Suppl 1): 156–158.

Tarnow, D.P., Cho, S.C. & Wallace, S.S. (2000) The effect of inter-implant distance on the height of inter-implant bone crest.Journal of Periodontoly 71: 546–549.

Tarnow, D.P., Magner, A.W. & Fletcher, P. (1992) The effect of the distance from the contact point to the crest of bone on the presence or absence of the interproximal dental papilla. Journal Peri- odontology63: 995–996.

Vailati, F. & Belser, U.C. (2007) Replacing four missing maxillary incisors with regular- or nar- row-neck implants: analysis of treatment options.

European Journal of Esthetic Dentistry2: 42–57.

Vela-Nebot, X., Mendez-Blanco, V., Rodriguez-Ciur- ana, X., Segala-Torres, M. & Gil-Lozano, J.A.

(2011) Implant positioning when replacing the four maxillary incisors: a platform-switched treat- ment option.The International Journal of Peri- odontics and Restorative Dentistry31: 375–381.

Weber, H.P., Buser, D., Fiorellini, J.P. & Williams, R.C. (1992) Radiographic evaluation of crestal bone levels adjacent to nonsubmerged titanium implants. Clinical Oral Implants Research 3: 181–188.

Zarb, J.P. & Zarb, G.A. (2002) Implant prosthodon- tic management of anterior partial edentulism:

long-term follow-up of a prospective study.Jour- nal of the Canadian Dental Association68: 92– 96.

Zinsli, B., Sagesser, T., Mericske, E. & Mericske- Stern, R. (2004) Clinical evaluation of small- diameter iti implants: a prospective study. The International Journal of Oral & Maxillofacial Implants19: 92–99.

Moraguez et al. Anterior maxillary fixed dental prostheses based on two narrow-diameter implants

Références

Documents relatifs

For mean bone loss according to smoking status adjusted for jaw, there was a significant difference in estimated mean bone loss at 10 year-follow-up between smokers and non-smokers (p

Elle s’applique lorsque la responsabilité de l’exposition dans la survenue de l’événement d’intérêt n’est plausible que dans un intervalle de temps limité,

6 60/M T3N0M0 Total maxillectomy þ radiation therapy þ chemotherapy Local recurrence, death 2 months later Sonobe, 1989 [17].. 7 53/M T4N0M0 Total maxillectomy þ craniofacial

The diagnosis of AHA is based on demonstrating an isolated prolongation of activated prothrombin thromboplastin time (APTT), not corrected by incubating for 2 h at 37 °C

Single-visit chairside adjustment of a metal-acrylic resin implant-supported fixed complete dental prosthesis on an unloaded implant using a novel fixed attachment system: a

Objectives: The aim of the present review was to compare the outcomes, that is, survival and complication rates of zirconia- ceramic and/or monolithic zirconia implant-

Nevertheless, wake hackle lines on the fracture surface of the glass layer indicate the crack propagation direction (black arrows) moving from the margin upwards towards the LS

[28] Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for pos- terior fixed partial dentures. Changes in the outcome