• Aucun résultat trouvé

Power Control of DFIG Driven by MatrixConverterUnder Super and Sub SynchronousOperationModes

N/A
N/A
Protected

Academic year: 2021

Partager "Power Control of DFIG Driven by MatrixConverterUnder Super and Sub SynchronousOperationModes"

Copied!
1
0
0

Texte intégral

(1)

J. Automation & Systems Engineering

Volume 11, Issue 2, 2017, Pages 141-151

Power Control of DFIG Driven by Matrix ConverterUnder Super and Sub Synchronous

OperationModes

K. Bedoud, T. BAHI, H. MERABET

Abstract: In this paper, we present the modeling and control of the wind energy conversion systemsbased on the doubly fed induction generator fed by AC/AC matrix converter. Firstly, wedeveloped the models of the different elements of the conversion chain. After, we consider thevector control strategy of the active and reactive powers in order to ensure an optimum operation.Finally, the dynamic model of a doubly fed induction generator and wind turbine grid connectedsystem is determined in the d-q synchronous reference frame.Therefore, the powers control isverified using software Matlab/Simulink. The behaviours of the sub-synchronous and supersynchronous operation modes is presented and discussed. The results prove that the power controlstrategy is well adapted to this kind of system.

Keywords : wind systems, doubly fed induction generator, Bidirectional DC-DC Converter, Variable Speed Wind Turbine

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

The bandwidth and controller gains for the current, power, torque and DC-link voltage control loops, tuned for the rated conditions, are presented in Table-3.2.. Table 3.2

Kumar, “Flux Based Sensorless Speed Sensing and Real and Reactive Power Flow Control with Look-up Table based Maximum Power Point Tracking Technique for Grid

It turns out that the true values of wind velocity, aerodynamic torque and rotor speed are needed in control systems meeting the MPPT objective.. The point is that mechanical

Index Terms —Wave energy converter (WEC), doubly-fed induction generator (DFIG), predictive power control..

Therefore, using robust control, such as the second-order sliding mode, will allow one to directly track the DFIG torque leading to maximum power extraction.. Moreover, the

Seifeddine BENELGHALI, Mohamed BENBOUZID, Jean-Frederic CHARPENTIER - Modeling and Control of a Marine Current Turbine Driven Doubly-Fed Induction Generator - IET Renewable

Index Terms—Doubly-fed induction generator (DFIG), high-order sliding mode (HOSM), marine current turbine (MCT), modeling, nonlinear controlM.

Sensorless Control of Doubly-Fed Induction Generator-Based Wind urbines using a High-Order Sliding Mode Observer... Sensorless Control of Doubly-Fed Induction Generator-Based Wind