• Aucun résultat trouvé

Absorb bioresorbable scaffold versus xience metallic stent for prevention of restenosis following percutaneous coronary intervention in patients at high risk of restenosis: rationale and design of the COMPARE ABSORB trial

N/A
N/A
Protected

Academic year: 2021

Partager "Absorb bioresorbable scaffold versus xience metallic stent for prevention of restenosis following percutaneous coronary intervention in patients at high risk of restenosis: rationale and design of the COMPARE ABSORB trial"

Copied!
4
0
0

Texte intégral

(1)

1

Absorb Bioresorbable Scaffold Versus Xience Metallic Stent for Prevention

of Restenosis Following Percutaneous Coronary Intervention in Patients at

High Risk of Restenosis: rationale and design of the COMPARE ABSORB

trial

Chun Chin Chang, MD; Yoshinobu Onuma, MD, PhD; Stephan Achenbach, MD, PhD; Emanuele Barbato, MD, PhD; Bernard Chevalier, MD; Stéphane Cook, MD; Dariusz Dudek, MD, PhD; Javier Escaned, MD, PhD; Tommaso Gori, MD, PhD; Viktor Kočka, MD, PhD, Giuseppe Tarantini, MD, PhD, Nick E.J. West, MD, Marie-Claude Morice, MD, Jan G.P. Tijssen, PhD, Robert-Jan van Geuns, MD, PhD; Pieter C. Smits, MD, PhD; on behalf of the COMPARE ABSORB trial investigators

(2)

2

I. Sample size calculation

Primary hypothesis I

• Non-inferiority in TLF (CVD/MI/TLR) at 1 year • TLF in Xience EES is 8.5%

• Non-inferiority margin is 4.5% • Alpha = 0.05

• Power = 90%

• Required sample size: 808 x 2 = 1616 pts

Primary Hypothesis II

• Superiority after 3-year landmark

• Expected TLF rate after 3 years with Xience EES is 11.1%

• Relative risk ratio from 3 to 7 years of Absorb BVS against Xience EES = 0.60 • Expected TLF rate with Absorb BVS is 6.64%

• Attrition rate 0.9%/ year • Sample size = 2100 • Statistical power = 90.3%

• The trial still has 80% power even if relative risk ratio from 3 to 7 years of Absorb BVS against Xience EES is 0.65.

Additional Hypothesis

• Cumulative superiority in TLF at 7 years

• Expected TLF rate with Xience EES at 7 year is 22.9%

• Absorb BVS reduces TLF at 7 years to 19.1% (relative risk ratio from 3 to 7 years of Absorb BVS against Xience EES is 0.60)

• With 2 x 1004 pts, the study has approximately 55% power of showing superiority of Absorb BVS over Xience EES within 7 years (α=0.05, two sided).

Secondary Hypothesis

• Using the data of ABSORB II trial, the cumulative incidence of angina endpoint at one year in the Xience EES arm is assumed to be 25%. With 2 x 1050 patients, the study has a 90% power to statistically detect a decrease to 19.1% in the Absorb BVS arm.

(3)

3

II. Study Organization

Principal investigator

Pieter C. Smits

Co-Principal investigator

Robert-Jan van Geuns

Executive Committee

Pieter C. Smits

Robert-Jan van Geuns Marie-Claude Morice Yoshinobu Onuma

Steering Committee members

Pieter C. Smits

Robert-Jan van Geuns Jan Tijssen Viktor Kočka Dariusz Dudek Bernard Chevalier Tommaso Gori Stephan Achenbach Giuseppe Tarantini Emanuele Barbato Nick West Javier Escaned Marie-Claude Morice Yoshinobu Onuma

Data Safety Monitoring Board (DSMB)

Stefan James Eric Boersma Michel Bertrand

Safety Reporting

The CRO CERC (7 rue du Théâtre, 91300 Massy, France) is responsible for entering all Serious Adverse Events (SAEs) including the assessment regarding relationship to the device (SADEs) or to the procedure from the eCRF in a safety database and for reporting these SAEs and SADEs according to the MEDDEV 2.7/3 guidelines and national requirements.

Data Management, Site Management and Monitoring

Data management, site management and monitoring will be conducted by the Clinical Research Organisation (CRO) CERC (7, rue du theatre, 91300 Massy, France).

Core Laboratories

The independent QCA and IVUS Core Lab at Cardialysis (Cardialysis B.V., PO Box 2125, 3000 CC Rotterdam, The Netherlands) will analyze angiograms obtained during and/or

(4)

4

before procedure. Members of the Angiographic/IVUS Core Lab are not involved as investigators or co-investigators in this study.

Statistical Analysis

The Cardialysis (Cardialysis B.V., PO Box 2125, 3000 CC Rotterdam, The Netherlands) is responsible for the statistical analysis.

Références

Documents relatifs

This ideal of civil independence must not be confounded with the factual capability of relatives in a given situation, where they may feel overwhelmed by the challenge to participate

Parmi les pistes à suivre : une plus grande prise de conscience de tous les professionnels de soins, une prévention renforcée auprès des plus jeunes mais aussi l’émergence

In ihrer Zusammenfassung beurtei- len die Autoren 2 der untersuchten Stu- dien mit niedrigem Bias-Risiko als posi- tiv zugunsten der Homöopathie [15, 16], 2 Studien mit

The results of ADONIS support both views: alien mollusc species influence the structure of the native macroinvertebrate community in a sandy flat of the littoral zone of

Premières Informations - Février 2009 - N° 07.1 4 par rapport à l’année précédente (%) par rapport au trimestre précédent (%) au 3 ème trimestre 2008 Évolution trimes-

Resource Repository Network • Manage and discover list of sources and resources • Maintain authentication and credentials. • Support

Latitudinal variability of minor species in the deep atmosphere of Venus is thought to arise from two physical phenomena: (1) that these minor species exhibit non-uniform vertical