• Aucun résultat trouvé

FROILOC® a novel food safety technology through localised cold and clean airflow

N/A
N/A
Protected

Academic year: 2021

Partager "FROILOC® a novel food safety technology through localised cold and clean airflow"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: hal-01413485

https://hal.archives-ouvertes.fr/hal-01413485

Submitted on 13 Dec 2016

HAL is a multi-disciplinary open access

archive for the deposit and dissemination of sci-entific research documents, whether they are pub-lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Distributed under a Creative Commons Attribution - NonCommercial - NoDerivatives| 4.0 International License

FROILOC® a novel food safety technology through localised cold and clean airflow

Georges Arroyo, Johan Carlier, Philippe Georgeault, Anthony Guibert, Dominique Heitz, Laurence Wallian

To cite this version:

Georges Arroyo, Johan Carlier, Philippe Georgeault, Anthony Guibert, Dominique Heitz, et al.. FROILOC® a novel food safety technology through localised cold and clean airflow. 8th In-ternational Conference on the Food Factory of the Future, Oct 2016, Laval, France. 2016, �10.13140/RG.2.2.21607.65441�. �hal-01413485�

(2)

FROILOC

R

a novel food safety technology through

localised cold and clean airflow

G. Arroyo, J. Carlier, P. Georgeault, A. Guibert, D. Heitz, L. Wallian

Irstea, UR OPAALE, 17 avenue de Cucill´

e - CS64427, 35044 Rennes, France

Some industries (food, pharmaceutical) require cold and ultraclean atmospheres. FROILOC R

(Patent number: PCT/FR2012/050582) blows clean and cold air over the work space while improving thermal comfort for operators thanks to warmer temperatures in the

ambient air of the workshop (Standard ISO7730, Criteria PMV). The installation includes a work space with two edges facing each

other, the means for distributing airflow in a localised space (work surface) and a set of transparent guide walls located in the extension of the air distribution device. The arrangement of stable aeraulic barriers is achieved due to the specific layout of aspiration methods as well as the interior and exterior walls. The airflow temperature is between −2o C and 4o C whilst ambient air in the facility is at least

13o C. A two-way access to the work zone allows two operators to work simultaneously and face-to-face.

FROILOC R

: Technical description

(a) Principle

Improves the quality and channelling of airflow distribution

Reduces the risks of mixing blown air with ambient air. The clean and cold airflow is channelled over the work station

receiving the products. The difference between the

temperature of the diffused air and the ambient air is at least 10o C and the cold air is between −2o C and 4o C.

Improves sanitary performance Satisfies the ISO 14644-1 Standard

(Clean Rooms and Related Controlled Environments): Level ISO5 for clean air in contact with sensitive products.

Improves work conditions (particularly in the agri-food industry)

Lowers the risks associated with musculoskeletal disorders: the thermal comfort of the operators is improved (meets ISO7730 standard ”Ergonomics in Thermal Atmospheres” and the PMV Index).

Reduces energy consumption

Two-way access to the work area Two operators working across

from each other can handle products whilst keeping their partner within their field of vision.

FROILOC R

: Results on temperature distribution

(b) Temperature map from simulation (FLUENT)

(c) Temperature over the table from experiments

FROILOC R

: Results on cleanness

(d) Particle trajectory from simulation (FLUENT)

(e) Particle concentration map over the table from experiments

(f) FROILOC R in food industry

Focus on fluid mechanics

Horizontally stratified Wall jet

Mean vertical velocity maps

(g) Hot jet (h) Cold jet

(i) Balance between Momentum and buoyancy fluxes

⇒ Modelisation of the effects of initial momentum and buoyancy on the behavior of wall jet

Vertically stratified mixing layer

(j) Flow visualizations of the mixing layer in stably and unstably strat-ified configurations at low flux Richardson number

⇒ Study of the effects of buoyancy on entrainment and mixing in mixing layer

Références

Documents relatifs

Students extracted some experimen- tal data of growth rate obtained in their food product (which is rare) or mainly in culture medium for the main microbiological hazards they

In the last decades substantial research efforts in the field of food microbiology have been devoted to unravel the mechanisms underlying stress responses and resistance development

There is now an urgent requirement for the industry to ensure compliance with measures to protect food workers from contracting COVID-19, to prevent exposure to or transmission

In this issue, the focus was on yersiniosis-related foodborne illnesses, behav- ior of Yersinia in foods, incidence, persistence, survival, or growth, outbreaks and

The main result is that if two symmetric …rms compete both in the output and in the permits market, the new equilibrium is again symmetric; whether in this new equilibrium …rms

In particular, the cap on emissions will be more or less restrictive depending on the elasticity of output demand and, together with the increase on emissions e¢ ciency due to the

As in Katz and Shapiro (1985), we find the conditions for an innovation (non-innovation or partial adoption) equilibrium to arise in a local market when firms expect a

[48] gather the information in exploration origin, environment detection and planting process into the data source of traceability in the light of the cultivation standards