LabVIEW-Based data acquisition system for eddy current testing probe

Meziane Hamel, Mouloud Zaidi, Farid Hocini, Hassane Mohelleb

Abstract : This paper presents the implementation aspects of a LabVIEW-Based data acquisition system intended for an eddy current testing (ECT) probe. The goal of this work is to design and develop a data acquisition system that can be used for automated non destructive testing tests and measurements applications. The system deals with a pancake type coil, placed above a flat copper plate with a crack. The probe coil moves along the crack length direction and is connected to a National Instruments (NI) data acquisition board. The system developed under this work has the capability to acquire the impedance of the coil. The experimental results are compared with LCR-meter measurements

Keywords : Data acquisition, eddy current testing, LabVIEW, sensor, impedance

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

We have used a 2D numerical model based on the Finite Element Method (FEM) to simulate the NDT inspection process and to predict the corresponding signal sensed by the GMR

A LabVIEW-Based data acquisition program was developed to continuously monitor the variation in the impedance of the coil and is observed on the computer

In order to make time resolved X-ray measurements from muscle one needs a suitable X-ray detector equipped with special electronics and software.. The requirements

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des

On each subsystem the main process has various message queue links with the EVB: an input queue for receiving control messages (also from other processes in the subsystem DAQ),

Le méningocoque est une bactérie sensible à de très nombreux antibiotiques, mais pour être utiles en cas de méningite cérébrospinale, ceux-ci doivent avoir une

the trajectories of upper and lower lip markers can be confused when the mouth closes and then opens. Reliable temporal trajectories, possibly incomplete, are built

VEGF increases the fibrinolytic activity of endothelial cells within fibrin matrices: involvement of VEGFR-2, tissue type plasminogen activator and matrix metalloproteinases....