• Aucun résultat trouvé

Polyelectrolytes Multilayer Films on titanium and titanium alloys for biomedical applications

N/A
N/A
Protected

Academic year: 2021

Partager "Polyelectrolytes Multilayer Films on titanium and titanium alloys for biomedical applications"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: hal-02004864

https://hal.univ-reims.fr/hal-02004864

Submitted on 2 Feb 2019

HAL is a multi-disciplinary open access archive for the deposit and dissemination of sci- entific research documents, whether they are pub- lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Polyelectrolytes Multilayer Films on titanium and titanium alloys for biomedical applications

C Brunot, L Mora-Ponsonnet, D Décoret, C Picart, B Beaugiraud, Brigitte Grosgogeat

To cite this version:

C Brunot, L Mora-Ponsonnet, D Décoret, C Picart, B Beaugiraud, et al.. Polyelectrolytes Multilayer

Films on titanium and titanium alloys for biomedical applications. eCells and Materials Journal, AO

Research Institute Davos, 2014, eCM-2014, 27 (suppl.1), pp.17. �hal-02004864�

(2)

European Cells and Materials

Polyelectrolytes Multilayer Films on titanium and titanium alloys for biomedical applications

C. Brunot

1,2

, L. Mora-Ponsonnet

3

, D. Décoret

1

, C. Picart

4

, B. Beaugiraud

5

, et B. Grosgogeat

1,6

1

Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université de Lyon, Equipe Biomatériaux et Interfaces Biologiques, UFR d’Odontologie, rue Guillaume Paradin, 69372 Lyon Cedex 08.

2

Faculté d’Odontologie, Université de Reims Champagne-Ardenne, 2 rue du Général Koenig, 51100 Reims.

3

Laboratoire de Bio-Ingénierie de Polymères Cardiovasculaires, INSERM U 698, Institut Galilée, Université Paris13, 99 avenue JB Clément, 93430 Villetaneuse.

4

Laboratoire des Matériaux et du Génie Physique, UMR CNRS 5628, MINATEC, 3 parvis Louis Néel, 38016 Grenoble.

5

Laboratoire de Tribologie et Dynamique des Systèmes, Ecole Centrale de Lyon, 36 avenue Guy de Collongue, 69134 Ecully Cedex.

6

Hospices Civils de Lyon, Service de Consultations et de Traitements Dentaires, 6-8 Place Depéret, 69365 Lyon Cedex 07.

INTRODUCTION: The aim of this research was to optimize titanium (Ti) and titanium alloy (NiTi) surfaces coated with Polyelectrolytes Multilayer Films (PMF)

[1]

. We studied different biomedical parameters related to this surface treatment in order to develop specific biomedical applications in the dental field (dental implants, endodontic instruments, orthodontic arches). Firstly, we determined if PMF had a detectable physisorbtion on Ti and NiTi. Secondly, we studied biocompatibility of poly-ethyleneimin (PEI), the precursor based- layer of PMF. Finally, sterilization tests were realized to analyze their potential impact on the physico-chemical structure of PMF.

METHODS: Two types of films were

caracterized : polystyrene-

sulfonate/polyallylamine hydrochloride films PEI-(PSS/PAH) and hyaluronic acid/poly-L- lysine films PEI-(HA/PLL). Physico-chemical characterization was carried out by tensiometry, atomic force microscopy (AFM), and confocal microscopy. A biological study using human fibroblasts was carried out. Cell response was observed after 0, 2, 4 and 7 days in vitro using morphologic criteria (scanning electron microscopy), adhesion (fluorescence microscopy image analysis), and proliferation (Methyl Tetrazolium Test). Three methods of PMF sterilization were compared: ultraviolets (UV), ethylen oxyde (ETO), and autoclave.

PSS/PAH films were characterized by the same physico-chemical tests and biological studies after the sterilization process.

RESULTS: Results showed that PSS/PAH films were more biocompatible than HA/PLL films on both metallic biomaterials. The precursor based-layer study demonstrated that

PEI was not biocompatible

[3]

. PMF sterilized by autoclave showed similar biocompatibility.

Such results could not be found with UV and ETO. Nevertheless, some investigations have to be realized to prove that the structure of PMF was not perturbed after these processes.

DISCUSSION & CONCLUSION: Based on our results, we decided to use PAH as the precursor based-layer (positively charged) and to stop using PEI on biomaterials made of Ti or NiTi. We are now planning to integrate bioactive molecules between layers of the PMF.

To this aim other parameters need to be studied to characterize in vivo potential biomedical application, such as films aging in the oral cavity, as well as in salivary or fluored environment.

REFERENCES:

[1]

Decher G. Fuzzy nanoassemblies: toward layered polymeric multicomposites. Science 1997,277:1232-7.

[2]

Brunot, C, Grosgogeat B, Picart C, Lagneau C, Jaffrezic-Renault N, Ponsonnet L. Response of fibroblast activity and polyelectrolyte multilayer films coating titanium. Dent Mater 2008,24(8):1025-35.

[3]

Brunot C, Ponsonnet L, Lagneau C, Farge P, Picart C, Grosgogeat B. Cytotoxicity of polyethyleneimine (PEI), precursor base layer of polyelectrolyte multilayers films.

Biomaterials 2007,28(4):632-40.

ACKNOWLEDGEMENTS: Timet

®

Savoie

society (Ugine, France) and AMF

®

society

(Lury sur Arnon, France) for providing

samples.

Références

Documents relatifs

Successive annealing of samples for 20 minutes at 450 °C (Fig. 6c) and 20 minutes at 500 °C shows the increase of TiO 2 cystallinity with the increase of the annealing temperature.

In other control experiments, we verified that no hydrogel films were produced when dry PAAm-PAAc spheres were immersed in 10wt% aqueous solutions of

Biomimetic implants can be provided from additive manufacturing with beta-titanium alloys We studied the properties of a Ti-Nb alloy elaborated with a laser deposition process.

Figures 6-14 shows the XRD diffractograms of the six sintered samples in the conditions defined. However, at 440°C, 10 min of processing is too long and crystallization occurs. By

On thicker titanium films (2-4 nm), when the two streaks g ω2 and g α1 are present, the silver layer exhibits a pecu- liar structure (figure 6 c). The diffraction pattern is composed

Cotton gauze samples modified with Cs and coated with HAp and Ag NPs (C- H2.5-Ag and C-H5-Ag) showed the highest peak intensity at 22.8 ◦ (Figure 5 b) compared with the

With the increase of a second crystalline phase (Ag) and the simultaneous growth of C(N) based amorphous phases, the films became slightly less porous. 6c) it is possible to see

The Al KB band from the alloys is shifted to lower energy and become sharpen band with narrow width compared with that of pure A l , because the change in the local density of