• Aucun résultat trouvé

Strain in a silicon-on-insulator nanostructure revealed by 3D x-ray Bragg ptychography

N/A
N/A
Protected

Academic year: 2021

Partager "Strain in a silicon-on-insulator nanostructure revealed by 3D x-ray Bragg ptychography"

Copied!
9
0
0

Texte intégral

(1)

HAL Id: hal-01205699

https://hal.archives-ouvertes.fr/hal-01205699

Submitted on 26 Sep 2015

HAL is a multi-disciplinary open access

archive for the deposit and dissemination of

sci-entific research documents, whether they are

pub-lished or not. The documents may come from

teaching and research institutions in France or

abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est

destinée au dépôt et à la diffusion de documents

scientifiques de niveau recherche, publiés ou non,

émanant des établissements d’enseignement et de

recherche français ou étrangers, des laboratoires

publics ou privés.

Strain in a silicon-on-insulator nanostructure revealed

by 3D x-ray Bragg ptychography

Virginie Chamard, Marc Allain, P. Godard, A. Talneau, G. Patriarche, M.

Burghammer

To cite this version:

Virginie Chamard, Marc Allain, P. Godard, A. Talneau, G. Patriarche, et al.. Strain in a

silicon-on-insulator nanostructure revealed by 3D x-ray Bragg ptychography. Scientific Reports, Nature

Publishing Group, 2015, 5, pp.9827. �10.1038/srep09827�. �hal-01205699�

(2)

Strain in a silicon-on-insulator

nanostructure revealed by 3D x-ray

Bragg ptychography

V. Chamard1, M. Allain1, P. Godard1, A. Talneau2, G. Patriarche2& M. Burghammer3

1Aix-Marseille Universite´, CNRS, Centrale Marseille, Institut Fresnel UMR7249, 13013 Marseille, France,2Laboratoire de

Photonique et de Nanostructures, CNRS, 91460 Marcoussis, France,3European Synchrotron Radiation Facility,

BP220, 38043 Grenoble, France.

Progresses in the design of well-defined electronic band structure and dedicated functionalities rely on the high control of complex architectural device nano-scaled structures. This includes the challenging accurate description of strain fields in crystalline structures, which requires non invasive and three-dimensional (3D) imaging methods. Here, we demonstrate in details how x-ray Bragg ptychography can be used to quantify in 3D a displacement field in a lithographically patterned silicon-on-insulator structure. The image of the crystalline properties, which results from the phase retrieval of a coherent intensity data set, is obtained from a well-controlled optimized process, for which all steps are detailed. These results confirm the promising perspectives of 3D Bragg ptychography for the investigation of complex nano-structured crystals in material science.

S

train fields in semiconductors are long proposed as a route for the design of well-defined electronic properties in microelectronic devices1. It relies on the modification of the electronic band structure,

reported for instance in silicon2or in germanium3,4. The case of the integration of strained semiconductors

to the widely used silicon-on-insulator (SOI) technology is of particular importance as the SOI technology offers the production of high-quality low-cost substrates associated to gains in device design, electronic performance and scalability5. In this context, the precise control of strain is mandatory. It includes the detailed knowledge of the

crystal lattice behavior within a given nanostructure morphology and with regards to the fabrication process. Indeed, not only the presence of surfaces and interfaces is susceptible to dramatically alter the expected electronic design, but the nanostructure elaboration itself6. This calls for experimental methods able to image the crystalline

properties in three dimensions (3D), over a large field of view, within a nanometer resolution and -ideally- in a non-pertubative way. Experimental approaches such as transmission electron microscopy7, x-ray Bragg

nano-diffraction8and finite-support Bragg coherent diffraction imaging9are well-established techniques for

strain analysis. They however only partly fulfill the required specifications justifying the development of an imaging approach capable of entirely answering this need.

The microscopy technique that we promote, namely Bragg ptychography, is an extension of the ptychography method which was originally implemented for electron microscopy applications10. It makes use of multiple

exposures that combine redundant information from partially overlapping illumination areas onto an extended sample11. A set of partially redundant far-field x-ray coherent intensity patterns is recorded while the sample is

translated through the finite-sized beam spot. As the measurement gives access only to the intensity (i.e. the squared amplitude) of the scattered wave-field, the image reconstruction relies on numerical approaches using iterative algorithms12. The retrieved complex-valued image is hence quantitative and contains information

directly related to structural parameters13. The main advantage of ptychography with regards to other x-ray

lens-less microscopy approaches9,14is its compatibility with the imaging of samples much larger than the

beam15,16. Indeed, x-ray beam sizes are primarily limited by the coherent lengths associated to the x-ray source

and/or detection scheme. They can be further decreased with focusing optics when the optimization of the flux at the sample position is required for the analysis of weakly scattering specimen. In addition, as ptychography is based on the deconvolution of the illumination and the sample scattering contrast functions, gains in resolution and sensitivity are achieved with regards to the ones obtained with the same experimental set-up used in a scanning mode approach17,18. Finally, in the particular case of the Bragg geometry, i.e. when the measurement is

SUBJECT AREAS: NANOSCALE MATERIALS MICROSCOPY Received 19 September 2014 Accepted 19 March 2015 Published 9 April 2015 Correspondence and requests for materials should be addressed to V.C. (virginie. chamard@fresnel.fr)

(3)

performed in the vicinity of a crystal Bragg reflection, ptychography acquires intrinsic 3D capabilities20–22together with, in principle, high

sensitivity to 3D crystalline displacement fields.

The possibility to image 3D extended crystals in a non invasive way using x-ray Bragg ptychography was proposed19and recently

experimentally demonstrated20–22. However, the capability to access a

relevant and therefore exploitable description of the 3D crystalline properties (e.g. displacement fields) at the nanoscale is still lacking in the Refs. [20–22]. In 2D, Hruszkewycz et al. demonstrated the pos-sibility to extract high fidelity structural information using Bragg projection ptychography23, 24. Here, we show that a highly controlled

experimental procedure allows to gain the ultimate robustness and sensitivity needed to produce a 3D high-fidelity image of the crys-talline properties. This ultimate control is achieved through an accurate knowledge of the x-ray illumination beam together with an optimized inversion procedure tested on shot-noise corrupted numerical data-sets. This crystal microscopy, applied to a litho-graphically patterned SOI structure, reveals displacement fields with details hardly accessible by other means.

Results

Experiments. The crystalline structure used for this study is patterned from a SOI wafer, whose top crystal, a 0:18 mm thick layer, is v110w oriented (see Methods). Scanning electron microscopy views of the structure external shape are presented in Figure 1. The shape of the patterned structure corresponds to the juxtaposition of two disks, a small and a large one, both of them

presenting inclined edges. Their diameters at the Siv110w/SiO2

interface are 0:77 mm and 0:26 mm, respectively. Although very simple, this shape exhibits only one symmetry plane, whose normal will be used as the translation direction during the ptychography experiments.

One major parameter of a ptychography experiment is the beam illumination function, whose knowledge is used for the deconvolu-tion operadeconvolu-tion performed during the ptychography inversion. Although blind deconvolution has been demonstrated for the ana-lysis of 2D ptychography intensity patterns25, 26, we observed, for 3D

Bragg ptychography, a significant increase of the retrieved image quality when the illumination is known21. This can be intuitively

understood by comparing the dimensionality of the problem to solve (the 3D phase of each intensity pattern) to the one of the acquired redundancy, which is only 2D at most (the two possible directions of the beam-to-sample scanning translations). Hence, prior to the 3D x-ray Bragg ptychography experiment itself, a detailed characteriza-tion of the profile of the x-ray nano-beam delivered by the synchro-tron experimental set-up was performed. The coherent nano-beam was produced by a partially and asymmetrically illuminated focusing lens27. In order to image the complex-valued illumination function at

the focal plane, a lens-less microscopy method was used, based on the simple and fast measurement of the over-focused direct beam intens-ity pattern, i. e., the freely propagated beam far from the focus. This latter was further phased with an error-reduction algorithm28,

wherein the wave propagation was performed by the Fresnel prop-agator. This approach requires the use of a well-defined support in a plane conjugated to the detection one (termed the numerical win-dow), in order to introduce a significant amount of known informa-tion (i.e., zero padding) allowing for the algorithm to converge. The ratio between the sizes of the numerical window and the support directly increases with the sampling frequency of the diffraction pattern. In our experimental set-up, this well-defined support con-straint was given by the slits defining the lens aperture. Hence, to guarantee that the numerical window located at the slit plane was much larger than the slit aperture (i.e., that the intensity was over-sampled), a high-resolution camera, with pixel size typically in the micrometer range, was used (see Methods). Figure 2a shows the over-focused direct beam intensity pattern, where the observation of the high frequency oscillations resulting from the slit truncated beam, demonstrates that the data quality fulfills this oversampling criterion. The resulting retrieved illumination function is shown in Figure 2b (see Methods). The asymmetry in the slit aperture results in an elongated central spot, with size of 0:75|0:56mm2 (distance

between the two first zeros), along the horizontal and vertical direc-tions, respectively, while the full-width-at-half-maximum (FWHM)

Figure 1|The crystalline silicon-on-insulator (SOI) structure as seen by scanning electron microscope. (a) Front view. (b) Same as (a), top view; The direction of the ptychography translation D (black arrow) and the scanning step D0are indicated. The projected direction of propagation of

the incident beam (white arrow) together with the beam footprint (FWHM of intensity, dotted ellipse) are shown. The gray ellipse corresponds to the beam footprint at the next beam-to-sample position. The (x,y,z) orthogonal laboratory frame is given.

Figure 2|Experimental considerations for 3D Bragg ptychography: beam profile and Bragg diffraction geometry. (a) Intensity pattern of the over-focused direct beam (arbitrary units) measured with a high-resolution camera. (b) Color rendition of the complex-valued beam profile, retrieved from the inversion of (a) and shown in the Fresnel zone plate focal plane. The brightness and color correspond to the linear scale amplitudea and to the phase Q, respectively. (c) Description of the 3D Bragg diffraction geometry, including the Bragg angle (hB), the incident and exit wave vectors (ki,f, respectively)

and the Bragg vector (G220). The 3D non-orthogonal (q1,q2,q3) detection frame is defined in agreement with the detection acquisition modality,

corresponding to the 2D detector plane and to the rocking curve direction. The (x,y,z) laboratory frame is also shown.

www.nature.com/scientificreports

(4)

of the central spot intensity is 0:31|0:23mm2. Beside providing valuable information for our Bragg ptychography experiment, we want to underline the convenience of this nano-beam characteriza-tion method, similar to the one presented in29,30, which is fast and

robust as long as the data oversampling is verified. It permits a high flexibility in the characterization of the beam profile during long-lasting synchrotron experiments.

The 3D Bragg diffraction ptychography data set was then acquired in the vicinity of the silicon 220 Bragg reflection (notedG220, with

jG220j~3:27:104mm{1), following the detection scheme shown in

Figure 2c. Details about the acquisition procedure can be found in the Methods section. Due to the incidence angle hB, the beam

foot-print was elongated (1:2|0:23mm2, Figure 1b so that the structure

was fully illuminated along the scattering plane, i. e the plane defined by the incident and exit wave vectors (ki,f, respectively). With this

specific geometry, the whole structure could be investigated by scan-ning the beam-to-sample position D along the axis normal to the scattering plane. The scanning step D0was fixed to 50 nm, ensuring

enough overlapping between two successive positions. Typical coherent diffraction patterns acquired at different D values and plot-ted in the detection frame, that is (q1,q2,q3) as shown in Figure 2c and

described in Methods, are presented in Figure 3. Note that the most central position along q0is slightly shifted by q0with regards to the

origin of the reciprocal space. The continuity and reproducibility of the different features observed in the diffraction patterns, further emphasized in the integrated intensity patterns of Figure 3b, are strong evidences of the absence of beam drift or radiation damage. Analysis of the 3D data set. Before we present the result of the ptychographic reconstruction, we show in the following the detailed analysis of the intensity data set. In addition to allowing for the estimation of the data quality, the detailed observation of the intensity data set brings valuable information on the sample crystalline properties. In particular the presence of a displacement field in a crystal is directly revealed by its Bragg diffraction pattern. This relies on a simple property of the Fourier transform, which is well adapted to describe the propagation of the scattered wave from the sample plane to the far-field detector. Fourier transforming a purely real function leads to a centro-symmetric intensity pattern. This situation corresponds to the strain-free crystal case9. On the

contrary, when an arbitrary displacement field is present in the crystal, it can be modeled by a phase field in the sample (complex-valued) scattering contrast31. This imaginary component breaks the

centro-symmetry of the diffraction pattern, with regards to q1,2,3~09.

This kind of behavior is observed in our data set. It is becoming more obvious when the beam is moving away from the central posi-tion, that is when one of the edges of the structure is strongly illu-minated. This is shown in Figure 3a for D~+7D0. For D~{7D0,

the strongest intensity lobe, emphasized by the white arrows and arising from the presence of the inclined edges, is observed for q2w0, for all q3 values. This corresponds to the situation where the centro-symetry of the 3D intensity pattern is broken with regards to the center of the Bragg peak (q1,2,3~0). A similar situation is

observed for D~7D0. However, the fact that the intense lobe is

observed for q2v0 (and not q2w0) is the signature of a phase field of opposite sign with regards to the D~{7D0case. On the contrary,

when the central part of the structure is illuminated (D<0), the most intense lobe is appearing on opposite sides of the diffraction pattern for q3increasing from negative to positive, a situation closer to the

strain-free case. This whole behavior (centro-symmetry for the central illumination position and break of centro-symmetry with opposite behaviors at the edge illumination positions) argues in favor of the presence of a displacement field at the edge of the silicon structure. Finally, possible refractions effects have been estimated and found to be negligible in the SOI structure32.

A second specific behavior is evidenced on the plots of the intens-ity patterns that were obtained after integration along q3at each fixed

D. They are shown in Figure 3b for the same Ds as previously selected. At D~0, the vertical streak along q1, corresponding to the thickness

interference fringes, presents a symmetric distribution with regards

Figure 3|3D Bragg ptychography data set. (a) Intensity patterns extracted from the 4D coherent Bragg diffraction measurements. For each frame, measured in the q1,q2plane, only the central part of the pattern is shown. The steps along q3correspond to +2dq3, relatively to the most

central positionq0while along the ptychography translation D, the steps

are +7D0(dq3~7:4mm{1and D0~50 nm). The intensity values in

+2dq3have been increased by a factor of 4 for sake of clarity. The white

arrows emphasize the stronger intensity lobes, which are arising from the structure edges. (b) Intensity integrated along the q3direction, for a fixed D, identical to (a). The dotted ellipses emphasize the missing intensity along the vertical streaks. In (a) and (b), the vertical and horizontal zero intensity lines correspond to blind pixels in the detector. The common logarithmic photon scale is shown in (b).

(5)

to q1~0. This symmetry is broken at other beam to sample position.

In D~{7D0, the streak is weaker for q1v0 (dotted ellipse in Figure 3b). This behavior is specific to the presence of a displacement field along the sample thickness. The fact that the opposite situation is observed for D~7D0shows that this displacement is not constant

along the translation direction.

Numerical simulations were performed in addition to the previous data analysis in order to evaluate qualitatively which displacement is producing a visible signature in the intensity data-set. This is par-ticularly relevant when dealing with limited signal to noise ratio intensities. In the following, the expected Bragg intensities calculated for different empirical crystalline strain states and using numerical parameters as close as possible to the experimental conditions (sam-ple shape and size, illumination function, sampling) are analyzed. The diffraction patterns shown for D~{7D0and plotted at

recip-rocal space coordinates identical to the ones used in Figure 3 are presented in Figure 4, for an intensity dynamical range comparable to the experimental data one. Three sample models have been chosen, with the same 3D shape and density, shown in Figure 4a. In Fig 4b and c, the strain-free case is first presented on the left column. The average intensity distribution reproduces fairly the experimental data. One notes that the edge streak is more inclined than the experimental one, showing a slight discrepancy between the edge inclinations in the model and in the silicon structure. More interestingly, the more intense lobe is appearing on opposite sides of the diffraction pattern when q3increases from negative to positive,

as expected for a centro-symmetric diffraction pattern produced by a strain-free crystal. The vertical streak evidenced in the integrated intensity pattern of Figure 4c is equally distributed along q1. The

middle column corresponds to the introduction of a displacement field developing at the edges of the structure. This leads to a break of the centro-symmetry, resulting in intensity lobes behaving similarly to the ones experimentally observed. However, the vertical streak visible in the integrated intensity plot of Figure 4c is still symmetric. The final introduction of an additional displacement at the interface (right column) breaks this symmetry along the thickness streak, leading to the definitive modification of the diffraction pattern, in good qualitative agreement with the experiment. It demonstrates that these simultaneous displacement fields at the edges and at the interface of the structure result to clear and observable signatures in the experimentally accessible data set. Reciprocally, the experiment-ally observed diffraction patterns could be explained by these dis-placement fields.

This preliminary experimental data analysis finally allows to pro-vide a relevant structural model, which is most likely representative of the structural features present in the SOI sample. Therefore, the optimization of the inversion procedure, which is presented in the following, is based on numerical tests performed on this very same structural model which is now the object to retrieve.

3D phase retrieval.Before the inversion of the experimental data set is performed, the inversion procedure needs to be optimized and quantified to ensure the pertinence of the retrieved image and its physical interpretation. Indeed, any inversion process brings its own artifacts due to the presence of photon shot noise33. Understanding

these effects requires a detailed analysis which allows to ensure that the best solution is found and permits to avoid over-interpretation of the retrieved image. Using the conclusion of the numerical simulation, different inversion procedures have been tested on an intensity data set produced by the third sample model of Figure 4, further described in Figure 5 (left column). Before inversion, the complete set of diffraction intensity patterns, calculated in the detection frame, was further corrupted by Poisson shot noise in order to take into account the limited amount of photons in the experiment.

Figure 4|Presence of a crystalline displacement field: numerical studies. Estimation of the expected diffraction patterns calculated for different 3D strained crystals with shape similar to the SOI structure. (a) Common 3D iso-surface rendering of the synthetic object together with the incoming beam shape (FWHM of intensity) for D~{7D0. The laboratory frame is

given; the length of the black lines is 100 nm. (b) Three synthetic models, corresponding to three different strain states and their corresponding diffraction patterns. The 2D sample description is shown in the plane indicated in (a) while the diffraction patterns are taken at the same D and q3values as the ones of (Figure 2, left column). (c) Intensity integrated along the q3direction, for the same D value. The specific features of the calculated diffraction patterns are emphasized by the white arrows and the dotted ellipse. The three strain states are as followed: (Left) The 3D strain-free crystal case. A 2D cut through the 3D amplitude is shown in (a). Note the assymetry in the spatial scale, which is underlined by the white lines, representing a 100 nm length. (Middle) Same calculation, obtained for a strained crystal: a displacement field with a radial symmetry is introduced at the edge of the structure. A 2D cut through the corresponding sample phase is shown at the top. (Right) Same as before with the simultaneous introduction of the displacement field at the edges and at the interface. This last model produces diffraction patterns in good agreement with the experimental ones.

www.nature.com/scientificreports

(6)

The inversion of the 4D intensity data was performed by optim-izing the approximation of the Poissonian likelihood proposed by Bouman and Sauer in Ref. [34] (see also Ref. [33] for details). This was done with a conjugate gradient algorithm chosen for its fast convergence property. The initial estimate was given by the shape of the synthetic model object (the phase was set to zero). Although the reconstruction shown in Figure 5 (second column) allows to recognize the sample structure, the image is clearly degraded, particularly with respect to the phase exact value in the vicinity of the edges. The obtained solution, which is of poor quality only, is therefore not acceptable for our purpose and calls for an improved inversion scheme. The next inversion corresponds to the same inver-sion process where an additional regularization has been introduced in order to bring reasonable physical information about the sample21.

Here we choose to consider the thickness of the sample: the solution we are seeking at is contained only into a film-like support. Due to the limited number of photons resulting in an expected spreading of the object induced by resolution effects, the thickness of the film has to be slightly larger (10 %) than the true object thickness. As can be seen in Figure 5 (third column), this process increases clearly the quality of the reconstruction, which can be hardly distinguished from the syn-thetic model object, validating the capability of Bragg ptychography to retrieve with a high fidelity the displacement field. A final test is performed to further quantify the solution quality. The same inver-sion process is used with an initialization given by the synthetic model object. Indeed in this case, the only remaining discrepancies between the solution and the model are expected to result from the presence of shot noise in the data set: shot noise corrupted data are naturally producing a band-limited image of the sample and this latter is inevitably corrupted by the inversion procedure itself and

its capability to deal with shot noise (i.e. the noise model). As can be seen on the right column of Figure 5, the retrieved solution in this last test is in excellent agreement with the solution obtained in the previous test. It confirms that the inversion process is optimum. Moreover, it gives a upper limit of the image quality expected for the experimental data. Based on this result, we used this last inversion process to phase back the experimental data set, without assumption on the strain state of the sample.

The whole set of experimental 3D intensity patterns is now ana-lyzed with the optimized 3D Bragg ptychography algorithm (see Methods). The initial guess is the strain-free model object with external shape close to the SOI pattern nominal shape. The result of the reconstruction, plotted in the orthogonal laboratory frame is shown in Figure 6. As can be seen, the external shape is retrieved with a good agreement with the nominal object shape depicted by scanning electron microscopy (Figure 6a,b and Figure 1). The internal density is rather homogeneous (Figure 6c). Some internal fluctuations remain, related most likely to experimental imperfec-tions (e.g., positioning accuracy). Note as well the presence of a bit of aliasing in the data set, which results in a slight truncation of the object along its longer dimension. This could have been easily overcome with the approach developed in Ref. [21] and does not represent an intrinsic limit of the method. The 3D plot allows finally to quantify the resolution, using the presence of sharp edges along the three direct space directions. The resolution voxel size is estimated to about 50|45|15 nm3along the x, y and z directions,

respectively.

More interestingly, 3D Bragg ptychography gives access to the phase w(r) of the retrieved complex-valued quantity. This quantity holds in principle information about the crystalline properties of the

Figure 5|Optimizing the inversion scheme. (Left) The 3D synthetic model object used to test the inversion procedure. It corresponds to the model shown on the right column of Figure 4. (Second column) Retrieved image using a conjugate gradient optimization of the Bouman and Sauer maximum likelihood, initialized with the shape of the object. (Third column) Same as before introducing an additional regularization term to constrain the sample support. (Right) Same as before, initialized with the true synthetic object. The top, middle and bottom rows are different cuts of the 3D object, as defined on the 3D isosurface plot rendition on the right. The assymetric spatial scale is given on left (y,z) and (x,y) cuts. Each line corresponds to a 100 nm length. The sample density and the displacement field color scales are indicated on the right. The excellent agreement observed between the two last retrieved solutions shows that the found inversion process is optimum.

(7)

lithographic structure and more precisely about the displacement field u(r) since31

w(r)~G220:u(r) ð1Þ

where r is the direct space coordinate. Hence, the projection of the displacement u220(r) can be extracted from the phase map using

u220(r)~w(r)=jG220j. This is shown in Figures 6d and 6e. As

expected from the raw data analysis and from the numerical simula-tions introducing strain, the measured displacement field exhibits visible variations at the edges of the structure and at the interface (emphasized in Figure 6f and 6g). This definitively confirms the capability of x-ray Bragg ptychography experiments to provide high fidelity images of displacement fields in 3D.

Discussion

The aim of this work was to demonstrate that 3D Bragg ptychogra-phy is a microscopy technique able at imaging with strong accuracy the crystalline properties of nano-structured crystal and is able thereby to bring valuable information for the understanding of struc-tural properties of complex crystalline nano-architecture. We think that our careful analysis, which includes the detailed investigation of the raw data, the strained crystal numerical simulations and the optimization of the inversion process, brings the decisive arguments to this demonstration.

Exploring the origin of the observed displacement field is out of reach of this work. A deeper understanding would require additional local structural information. Transmission electron microscopy (TEM) could provide the desired strain sensitivity and resolution, but the sample preparation, which requires the thinning down of the isolated SOI structure is particularly tricky and subjected to the introduction of relaxations or defects. The investigation of a series of patterned Si structure prepared from varying lithographic para-meters is mandatory to explore the precise relationship between the crystalline structure and the sample shape, size and preparation pro-cesses. In spite of these difficulties, we can however argue that the

crystalline behavior at the interface is likely related to the fabrication process of the SOI wafer. A similar interfacial structure was observed in Ref. [20]. In addition, the investigation of the considered interface, performed with TEM on the un-patterned SOI wafer, shows as well a strain field (ezz) at the interface (Figure 7). However, the detailed

comparison between the TEM and the x-ray results is vain due to the strong difference in the image resolution. Indeed, this requires the introduction of the resolution function parameters (resolution func-tion model, relative posifunc-tion of interface in TEM and x-rays) for which a good agreement between TEM and x-rays images can always be found. In addition, finite element models (FEM) were performed in order to bring some insights to the presence of the displacement field located at the edge of the structure. This calculation is based on continuum elasticity theory, using the intrinsic properties of the materials (i.e. the elastic constants) and does not take into account the preparation history. The fact that the displacement fields could not be reproduced by FEM is an argument in favor of a lithograph-ically induced strain field at the edges.

To conclude, we have shown that an optimized 3D x-ray Bragg ptychography method, including illumination function knowledge and regularized inversion procedure, possesses the capability to pro-vide high fidelity images of strain fields in nanostructured crystals without dedicated sample preparation. These specificities are required for addressing pending problems in a wide variety of phys-ical or biologphys-ical material science. We expect that this method will generalize together with the development of the forthcoming x-ray sources and instruments.

Methods

Sample preparation.The SOI wafer is composed of a Siv110w top layer (0:18 mm) and SiO2layer (0:02 mm) on a Siv001w substrate. The patterning method involved

e-beam lithography and SF6-based reactive ion etching to produce inclined edges. Due to the crystallographic orientation difference between the top layer and the substrate, it was possible to image solely the Si top structure.

Experiment: beam profile determination.The x-ray experiment was performed at the ID13 beamline at ESRF (European Synchrotron Radiation Source) with a monochromatic beam of wavelength l~0:1 nm and bandwidth dl=l<10{4.

Figure 6|3D x-ray Bragg ptychography image of the SOI structure. (a) 3D Isosurface plot rendition of the retrieved crystalline SOI structure density, shown in the laboratory frame (threshold at 30%). The length of the frame black lines corresponds to 0.1 mm. (b) Same as (a), other view. (c) Orthogonal 2D cuts of the density. (d) Orthogonal 2D cuts of the displacement field component u220. The color scale used to plot the u220images is given

at the bottom. (e) 2D cut in the (y,z) plane extracted from (d). The specific behavior of u220is emphasized in the 1D cuts taken along the colored lines in

(f) and (g).

www.nature.com/scientificreports

(8)

The finite-sized beam spot needed for the ptychography scan resulted from the focalisation of a fully coherent beam using a Fresnel zone plate (FZP) with focal length of 0:14 m. For this purpose, the FZP aperture was reduced to 60|40mm2in the

vertical and horizontal direction, respectively, so that the illumination area matched the beam transverse coherence lengths. As the FZP central part was occluded by a beam stop to avoid direct beam contribution, the aperture was shifted laterally by 60 mm.

The overfocused direct beam measurement was performed with a high-resolution camera (pixel size of about 1:8mm) located at 1.72 m from the lens focal plane. The intensity pattern is the result of 100 acquisitions of 1s each, where the zero photon background has been subtracted. The inversion of the intensity data is performed as described in29, using a rough estimate of the beam profile as a starting guess.

Numerical tests introducing photon shot noise show that a solution of relevant quality is obtained even if the support knowledge is known within 615%.

Experiment: 3D Bragg ptychography acquisition.The sample was mounted vertically onto a three-axis piezo stage, fixed on the top of an hexapod. The accurate alignment of the sample center of rotation with regards to the focal plane was ensured by the use of an optical microscope with a depth of focus of about 1 mm. The sample was rotated to the Bragg angle hBof the 220 reflection (hB~15:10), which resulted in

an elongated focal spot size of 1:2|0:23 mm2, as schematically shown in Figure 1b.

The intensity acquisition was performed with a Maxipix single photon detector (516 x 516 pixels of 55 mm size), located at 2.25 m from the sample. At each position of the beam onto the sample, the sample was rotated in steps of 0.0130, along the rocking

curve. This angular sampling allowed to ensure that the exit field was fully contained into the conjugated space associated to the detector frame21. The 20 frames were then

stacked in order to provide the full 3D intensity pattern, for a given beam to sample position. Each intensity pixel was associated to a reciprocal space vector q~kf{ki,

with coordinates q1,q2, and q3. Precisely, q1and q2are defined along the detector

frame, parallel and perpendicular to the incident plane, respectively, while q3

corre-sponds to the direction of the rocking curve, i.e., is tangent to the 220 Bragg vector. In order to acquire partially redundant information, the sample position D was scanned along y in steps of 50 nm (Figure 1b), resulting in an overlapping of 78 %. The total scanning range (21 steps) ensured that the whole structure was explored. The acquisition time (30 s per frame) led to an intensity maximum of about 5700 photons/pixel.

Inversion of the experimental data set.The inversion of the intensity data set was performed directly in the detector frame in order to keep the truly measured intensity value in each detector pixel. It preserves thereby the statistical properties of the photon shot-noise corrupted signal. Consequently, the conjugated direct space frame into which all the parameters linked to the sample are described is non-orthogonal21.

During the inversion procedure, the illumination function was kept fixed. Its 3D

distribution was derived from the beam profile estimated in Figure 2, which was considered as constant along the propagation depth into the sample.

The inversion cycle was initialized by the sample starting estimate, a strain-free structure with external shape close to the SOI pattern nominal shape. In addition, in order to avoid the reconstruction of ambiguous solutions due to the lack of diversity along the beam propagation direction, the search of regularized solutions was enforced21, penalizing the reconstruction of the object outside a film-like support

(0:2 mm thick). The conjugate gradient algorithm was used for the inversion, together with a Bouman and Sauer description of the shot-noise probability distribution function34, 33. This latter was chosen for its capacity to emphasize the low frequency

components, leading to smooth solutions. Other noise models were tested, resulting qualitatively to the same results.

Transmission electron microscopy (TEM).High-resolution TEM observations were obtained on a JEOL 2200FS microscope equipped with an ultra-high resolution pole piece and working at 200 keV. The v001w cross-sectional preparations have been done by mechanical polishing followed by an argon ion beam milling until the electron transparency (with a low voltage of 2 kV at the end, to limit the thickness of amorphous layer on the sides of the preparation). Strain mapping analysis were performed using the geometrical phase analysis (GPA) software (for more informations see Refs. [35, 36]). The z axis of the sample (Figure 1) corresponds to the v110w direction.

1. Bedell, S. W., Khakifirooz, A., and Sadana, D. K. Strain scaling for CMOS. MRS Bulletin 39, 131–137, 2 (2014).

2. Roberts, M. M., et al. Elastically relaxed free-standing strained-silicon nanomembranes. Nat. Mater. 5, 388–393, 2006.

3. Liu, J., Sun, X., Camacho-Aguilera, R., Kimerling, L. C., and Michel, J. Ge-on-Si laser operating at room temperature. Opt. Lett. 35, 679–681, 2010.

4. Suess, M. J., et al. Analysis of enhanced light emission from highly strained germanium microbridges. Nat. Phot. 7, 466 (2013).

5. Celler, G. K., and Cristoloveanu, S. Frontiers of silicon-on-insulator. J. Appl. Phys. 93, 4955 (2003).

6. Xiong, G., et al. Elastic relaxation in an ultrathin strained silicon-on-insulator structure. Appl. Phys. Lett. 99, 114103 (2011).

7. Hy¨tch, M., Houdellier, F., Hu¨e, F., and Snoeck, E. Nanoscale holographic interferometry for strain measurements in electronic devices. Nature 453, 1086–1089 (2008).

8. Stangl, J., Mocuta, C., Chamard, V., and Carbone, D. Nanobeam X-ray Scattering: Probing matter at the nanoscale. Wiley (2013).

9. Newton, M. C., Leake, S. J., Harder, R., and Robinson, I. K. Three-dimensional imaging of strain in a single ZnO nanorod. Nat. Mater. 9, 120 (2010). Figure 7|Transmission electron microscopy at the Si/SiO2interface (a) Transmission electron microscopy image of the Si ,110./SiO2interface

measured on the un-patterned SOI wafer. The crystallographic directions of the Siv110w layer are indicated. (b) The ezzstrain component extracted

from (a), in absolute units. The inset shows the mean value of ezzas a function of the distance to the interface, calculated in the region delimited by the

(9)

10. Hoppe, W. Beugung im inhomogenen Primrstrahlwellenfeld. Prinzip einer Phasenmessung von Elektronenbeungungsinterferenzen. Acta Crystallograph. A. 25, 495 (1969).

11. Rodenburg, J. M., and Bates, R. H. T. The theory of super-resolution electron microscopy via Wigner-distribution deconvolution. Philos. T. Roy. Soc. A 339, 521 (1992).

12. Faulkner, H. M. L., and Rodenburg, J. M. Movable aperture lensless transmission microscopy: A novel phase retrieval algorithm. Phys. Rev. Lett. 93, 023903 (2004). 13. Diaz, A., et al. Quantitative x-ray phase nanotomography. Phys. Rev. B 85, 020104

(2012).

14. Chamard, V., et al. Three-dimensional x-ray Fourier transform holography: the Bragg case. Phys. Rev. Lett. 104, 165501 (2010).

15. Rodenburg, J. M., et al. Hard-x-ray lensless imaging of extended objects. Phys. Rev. Lett. 98, 034801 (2007).

16. Dierolf, M., et al. Ptychographic X-ray computed tomography at the nanoscale. Nature 467, 436 (2010).

17. Mocuta, C., et al. Beyond the ensemble average: X-ray microdiffraction analysis of single SiGe islands. Phys. Rev. B 77, 245425 (2008).

18. Vine, D. J., et al. Simultaneous X-ray fluorescence and ptychographic microscopy of Cyclotella meneghiniana. Opt. Express. 20, 18287 (2012).

19. Hruszkewycz, S. O., et al. Framework for three-dimensional coherent diffraction imaging by focused beam x-ray Bragg ptychography. Opt. Lett. 36, 2227 (2011). 20. Godard, P., et al. Three-dimensional high-resolution quantitative microscopy of

extended crystals. Nat. Commun. 2, 568 (2011).

21. Berenguer, F., et al. X-ray lensless microscopy from undersampled diffraction intensities. Phys. Rev. B 88, 144101 (2013).

22. Huang, X., et al. Three-dimensional Bragg coherent diffraction imaging of an extended ZnO crystal. J. Appl. Crystallogr. 45, 778 (2012).

23. Hruszkewycz, S. O., et al. Quantitative nanoscale imaging of lattice distortions in epitaxial semiconductor heterostructures using nanofocused x-ray Bragg projection ptychography. Nanolett. 12, 5148 (2012).

24. Hruszkewycz, S. O., et al. Imaging local polarization in ferroelectric thin films by coherent x-ray Bragg projection ptychography. Phys. Rev. Lett. 110, 177601 (2013). 25. Thibault, P., et al. High-resolution scanning x-ray diffraction microscopy. Science

321, 379–382 (2008).

26. Maiden, A. M., and Rodenburg, J. M. An improved ptychographical phase retrieval algorithm for diffractive imaging. Ultramicroscopy 109, 1256 (2009). 27. Schroer, C. G., et al. Coherent x-ray diffraction imaging with nanofocused

illumination. Phys. Rev. Lett. 101, 090801 (2008).

28. Fienup, J. R. Reconstruction of a complex-valued object from the modulus of its Fourier transform using a support constraint. J. Opt. Soc. Am. A 4, 118 (1987). 29. Quiney, H. M., Peele, A. G., Cai, Z., Paterson, D., and Nugent, K. A. Diffractive

imaging of highly focused x-ray field. Nat. Phys. 2, 101 (2006).

30. Mastropietro, F., et al. Coherent x-ray wavefront reconstruction of a partially illuminated Fresnel zone plate. Opt. Express. 19, 19223 (2011).

31. Takagi, S. A dynamical theory of diffraction for a distorded crystal. J. Phys. Soc. Jpn. 26, 1239 (1969).

32. Harder, R., Pfeifer, M. A., Williams, G. J., Vartaniants, I. A., and Robinson, I. K. Orientation variation of surface strain. Phys. Rev. B 76, 115425 (2007). 33. Godard, P., Allain, M., Chamard, V., and Rodenburg, J. Noise models for low

counting rate coherent diffraction imaging. Opt. Express. 20, 25914 (2012). 34. Bouman, C. A., and Sauer, K. A unified approach to statistical tomography using

coordinate descent optimization. IEEE Trans. Image Process. 5, 480–492 (1996). 35. Ishizuka, K., A dedicated Site for Quantitative Electron Microscopy, date of access

06/01/2015, http://www.hremresearch.com.

36. Hytch, M. J., Snoeck, E., and Kilaas, R. Quantitative measurement of displacement and strain fields from HREM micrographs. Ultramicroscopy 74, 131–146 (1998).

Acknowledgments

We are grateful to L. Capello from SOITEC, who provided the SOI substrate. J. Daillant and C. Chevallard are warmly acknowledged for their help during the synchrotron experiment. J. Stangl and N. Hrauda are warmly acknowledged for fruitful discussions. The ESRF is acknowledged for allowance of beamtime and the use of the ESRF source. This work is funded by the French ANR under project number ANR-11-BS10-0005.

Author contributions

The research project was designed by VC. The sample was prepared by AT and the TEM experiments were performed by GP. MB prepared the experimental set-up at the synchtrotron and performed the x-ray measurements together with VC. VC analysed the data together with the help of MA. The manuscript was written by VC, PG and MA with the help of all others.

Additional information

Supplementary informationaccompanies this paper at http://www.nature.com/ scientificreports

Competing financial interests:The authors declare no competing financial interests. How to cite this article:Chamard, V. et al. Strain in a silicon-on-insulator nanostructure revealed by 3D x-ray Bragg ptychography. Sci. Rep. 5, 9827; DOI:10.1038/srep09827 (2015). This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder in order to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

www.nature.com/scientificreports

Figure

Figure 2 | Experimental considerations for 3D Bragg ptychography: beam profile and Bragg diffraction geometry
Figure 4 | Presence of a crystalline displacement field: numerical studies.
Figure 7 | Transmission electron microscopy at the Si/SiO 2 interface (a) Transmission electron microscopy image of the Si ,110./SiO 2 interface measured on the un-patterned SOI wafer

Références

Documents relatifs

La dernière partie présente une hybridation entre les métaheuristiques de base (AG-RT) et les métaheuristiques avec une méthode analytique quasi-Newtonienne (RT-QN, AG-QN). Mots

first demonstration in 2001, 24 x-ray Bragg coherent diffraction imaging has been proven as a 68.. powerful method to investigate crystalline properties of materials 25 in

In this paper, we have demonstrated that near-field ptychographic phase retrieval can be used to obtain a tomographic dataset for local nano CT of a strongly absorbing and

The spatial distribution of the lattice distortion can be visualized through a series of X-ray diffraction topo- graphs recorded along the rocking curves, which allows real- space

5.2 , which presents the obtained results in the vicinity of the intense InP peak, we can see that the proposed diffraction patterns are well reproduced with respect to the

The detectors usually installed on the soft x-ray end-station are widely based on back-side illuminated CCD sensor such as the commercial cameras from Princeton© PI-MTE

Médecine Nucléaire Chimie Thérapeutique Toxicologie Pédiatrie Anatomie Pathologie Anatomie Anesthésie Réanimation Radiologie Physiologie Radiologie Pédiatrie Médecine

La corrélation entre le résultat de l’antibiogramme et celui du traitement n’est pas toujours satisfaisante. Pour le MAC, c’est le résultat de l’étude à