• Aucun résultat trouvé

Chemical and toxicological profiling of large rivers using mobile passive sampling and comparison to large volume active sampling

N/A
N/A
Protected

Academic year: 2021

Partager "Chemical and toxicological profiling of large rivers using mobile passive sampling and comparison to large volume active sampling"

Copied!
3
0
0

Texte intégral

(1)

HAL Id: ineris-01863853

https://hal-ineris.archives-ouvertes.fr/ineris-01863853

Submitted on 29 Aug 2018

HAL is a multi-disciplinary open access archive for the deposit and dissemination of sci- entific research documents, whether they are pub- lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Chemical and toxicological profiling of large rivers using mobile passive sampling and comparison to large volume

active sampling

Klara Hilscherova, Branislav Vrana, Jiri Novak, Foppe Smedes, T. Rusina, K.

Okonski, Selim Ait-Aissa, Werner Brack, Nicolas Creusot, Beate I. Escher, et al.

To cite this version:

Klara Hilscherova, Branislav Vrana, Jiri Novak, Foppe Smedes, T. Rusina, et al.. Chemical and

toxicological profiling of large rivers using mobile passive sampling and comparison to large volume

active sampling. 27. SETAC Europe annual meeting, May 2017, Bruxelles, France. �ineris-01863853�

(2)

Chemical and toxicological profiling of large rivers using mobile passive sampling and comparison to large volume

active sampling

Klára Hilscherová

1

, Branislav Vrana

1

, J iří Novák

1

, Foppe Smedes

1

, Tatsiana Rusina

1

, Krzysztof Okonski

1

, Selim Ait-Aissa

2

, Werner Brack

3,4

, Nicolas Creusot

2

, Beate Escher

3,5,6

,

Roman Grabic

7

, Martin Krauss

3

, Peta Neale

5,8

, Tobias Schulze

3

, Jaroslav Slobodník

9

1

Research Centre for Toxic Compounds in the Environment (RECETOX), Masaryk University, Brno, Czech Republic

2

Institut National de l'Environnement Industriel et des Risques (INERIS), Verneuil en Halatte, France

3

UFZ Helmholtz Centre for Environmental Research, Leipzig, Germany

4

Dept.of Ecosystem Analysis, Institute for Environmental Research, RWTH Aachen University, Germany

5

Smart Water Research Centre, Griffith University, Southport, Australia

6

Eberhard Karls University Tübingen, Germany

7

University of South Bohemia, Faculty of Fisheries and Protection of Waters, Vodňany, Czech Republic

8

The University of Queensland, National Research Centre for Env.Toxicology (Entox), Brisbane, Australia

9

Environmental Institute, Koš, Slovakia

E-mail contact: [email protected]

Introduction and Methods :

Freshwaters often contain complex mixtures of many different pollutants, some at trace concentrations, thus the toxic potential and risk associated with these mixtures are difficult to predict. Efficient sampling methods together with sensitive effect based tools can significantly improve the risk assessment.

Novel mobile “enhanced” passive sampling system (EPS) for sampling of trace organic pollutants was successfully applied within the Joint Danube Survey 3 (JDS 3) during August and September 2013. In this device the diffusive uptake of contaminants is enhanced by jet streaming water along the sampler surface performed by a submersible pump. The EPS was installed on board of expedition ship and during a typical sampling period of 5 days the ship moved downstream along a defined stretch. The samplers accumulated water pollutants integrated in time and space over 8 river stretches. The partitioning samplers for non-polar compounds, i.e. silicone rubber sheets, and an adsorption sampler for polar compounds based on Empore SPE disks (SDB-RPS; reversed-phase sulfonate) were applied. Both samplers were extracted with organic solvents for chemical analyses and toxicological profiling.

Spot sampling of high water volumes was conducted by large volume solid phase extraction (LVSPE) at 22 sites along the river (on both the Danube River and its tributaries) during JDS 3. Up to 500 L of water were passed through large volume solid phase extraction system (Maxx GmbH, Rangendingen, Germany) consisting of a stainless-steel chamber containing neutral sorbent Chromabond HR-X, anionic exchanger Chromabond HR-XAW, and cationic exchanger Chromabond HR-XCW (Macherey-Nagel, Dueren, Germany). After extraction, each solid phase was freeze-dried and then extracted with solvents, and the eluates were combined. Extracts of samples from both EPS and LVSPE were subjected to analysis of a wide range of organic pollutants and to toxicological profiling. Bioanalytical tools were applied complementary to chemical analysis to detect the effects of complex chemical mixtures. The endpoints studied in all listed types of samples included toxic potentials for causing endocrine disruption (estrogenic, anti/androgenic), dioxin-like activity, pregnane X receptor (PXR)-mediated activity and oxidative stress-associated response.

Results and Discussion

Passive sampling as well as application of large volume solid phase extraction enabled to identify spatial profiles of a broad range of organic pollutants and studied toxicological endpoints in the water column. In many cases the integrative character of passive sampling allowed measurement of compounds at pg L

-1

levels where conventional grab sampling of water applied in previous surveys failed to detect them.

Besides oxidative stress response, toxic equivalents were detected in a similar range for active and passive

sampling (Fig.1). The passive sampling reflected the physical-chemical characteristics of the compounds

driving individual effects. While the PXR-mediated and estrogenic effect potentials were detected namely in

Empore samplers, thus were elicited mainly by polar chemicals, AhR-mediated effect potential was primarily

detected in silicone rubber samples, which reflects significant contribution of less polar compounds.

(3)

Figure 1: Comparison of toxic potentials of samples from large volume active sampling and passive sampling during JDS3

The bioanalytical equivalent concentration (BEQ) approach was used to characterize the contribution of the detected chemicals to observed toxic potentials and identify the main toxicity drivers. The fraction of

biological effects explained by the detected chemicals in samples from mobile “enhanced“ passive sampling of water from the Danube river differed depending on the studied effect and the type of sampler (Fig. 2). For example, estrogenicity and AhR-mediated potential were explained relatively well in Empore sampler (mainly polar compounds), with 17β-estradiol and 17α-ethinyl estradiol being responsible for most of the calculated estrogenic potential. On the other hand, most of the estrogenicity and AhR-mediated potential in silicon rubber samples (non-polar chemicals) was not explained by the measured chemicals. The detected chemicals contributed only little to some other endpoints, such as oxidative stress-associated response.

Figure 2: Fraction of toxic potentials in passive samples from the 8 river stretches explained by levels of detected chemicals

Our study demonstrates the utility of the integrated approach using toxicological profiling to characterize fresh water pollutant mixtures along with chemical analysis in monitoring of fresh water quality and the very good applicability of both passive sampling and large volume solid phase extraction in this assessment.

Acknowledgements: This research was supported by SOLUTIONS Project from the European Union Seventh Framework Programme (FP7-ENV-2013-two-stage Collaborative project) under grant agreement no. 603437.

1 2 3 4 5 6 7 8

0 2 4 6

Estrogenicity Silicone Rubber

` contribution of chemicals [%]

p,p’-DDT tert-octylphenol 4-Nonylphenol p,p’-DDD o,p’-DDT BPA

1 2 3 4 5 6 7 8

0 100 200 300

Estrogenicity EMPORE

contribution of chemicals [%]

BPA

tert-octylphenol 4-Nonylphenol E2-alfa E3 E1 E2-beta EE2

1 2 3 4 5 6 7 8

0 1 2 3

AhR-mediated toxic potential Silicone Rubber

` contribution of chemicals [%] Benzo(k)fluoranten Benzo-j-fluoranthene Chrysen nonylphenol Benzo(a)pyren Benzo-b-fluorene Pyren Benzo(b)fluoranten Fluoranthene Benz(a)anthracen Cyclopenta-cd-pyrene

Benzo-e-pyrene Indeno(123cd)pyren Dibenz(ah)antracen

1 2 3 4 5 6 7 8

0 50 100 150

AhR-mediated toxic potential EMPORE

contribution of chemicals [%]

terbutylazin Chrysen nonylphenol propiconazole Benzo-b-fluorene Pyren Fluoranthene Benz(a)anthracen diuron prochloraz chlorpyrifos Benzo-e-pyrene diazinon LVSPE

PA S EM

PO RE

PA S SR 0

5 10 15 20

AhR-mediated toxic potential-RECETOX

bioTEQTCDD (pg/L)

LVSPE PA

S EM PO

RE PA

S SR 0.0

0.5 1.0 1.5 2.0 2.5

PXR-mediated toxic potential-INERIS

bioTEQSR12813 (µg/L)

LVSP E

PA S EM

PO RE

PA S SR 0

100 200 300 400

Estrogenic potential-INERIS

bioTEQE2 (pg/L)

LVSPE PA

S EM PO

RE PA

S SR 0

5 10 15 20

Oxidative stress potential (AREc32) UQ/UFZ

bioTEQtBHQ (µg/L)

Références

Documents relatifs

Studies have shown than results obtained from sampling with a flux chamber (low flow - isolation chamber type) and wind tunnel (high flow) could be very different (Bokowa,

While under normal traffic conditions most benzene roadside concentrations measured during the day under low wind speed conditions exceeded the European limit value of 5 ug/m3,

Unequal probability sampling without replacement is commonly used for sample selection, for example to give larger inclusion probabilities to units with larger spread for the

The strong exponential correlation (R 2 0.97) between the culturable cell counts in water and the pipe surface-to-volume ratio suggests the biofilm as the main contributor to the

We will also give three polynomial algorithms (in O(n 3 ) operations where n is the number of elements) for dealing with those dissimilarities: one to check if a given dissimilarity

Depuration compounds are normally used during an actual sampling campaign to be directly compared with the pollutants detected. Since we studied DC on their own, sampling

The results of the dispersion model approach indicate that PM10 exposure has no statistically significant effect on hospital admissions for cardiovascular and respiratory diseases

Artifact formation in high volume sampling of voc’s and solid organic compounds.. Eva Leoz-Garziandia, Angels Castellnou, Norbert Gonzalez-Flesca,