i n t e rna t i onal journal o f hydrogen energy

Volume 43, Issue 25, 2018, Pages 432-441

Study of a double fed induction generator usingmatrix converter: Case of wind energy

conversionsystem

K. Bedoud, A. Rhif, T. BAHI, H. MERABET

Abstract: Due to the growing of the power electronics, especial attention has been given to the use ofnew generation of power converters, AC/AC matrix converter to which provide a directpower converter AC/AC, bi-directional power flow, almost sinusoidal input and outputwaveform. In this paper, we present the performance study of a variable-speed windturbine based on doubly fed induction generator fed by matrix converter using themaximum power point tracking method to extract the maximum power available. Thewhole system is presented in d-q-synchronous reference frame. The control scheme istested and the performances are evaluated by simulation results. The simulation resultsobtained under MatLab/Simulink show the effectiveness and validity of the consideredcontrol.

Keywords : Wind turbine, Control, Maximum power tracking, matrix converter, doubly fed induction generator

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

Index Terms —Wave energy converter (WEC), doubly-fed induction generator (DFIG), predictive power control..

Therefore, using robust control, such as the second-order sliding mode, will allow one to directly track the DFIG torque leading to maximum power extraction.. Moreover, the

Seifeddine BENELGHALI, Mohamed BENBOUZID, Jean-Frederic CHARPENTIER - Modeling and Control of a Marine Current Turbine Driven Doubly-Fed Induction Generator - IET Renewable

Sensorless Control of Doubly-Fed Induction Generator-Based Wind urbines using a High-Order Sliding Mode Observer... Sensorless Control of Doubly-Fed Induction Generator-Based Wind

Furthermore, analysis of the stator current was conducted in healthy cases and in the presence of defects, the second method of fault detection in this work,is based on

1) Interchanging the chariots to observe if the problem is due to a component installed in the chariot. 2) Measuring all three rotor currents instead of two. 3)

The bandwidth and controller gains for the current, power, torque and DC-link voltage control loops, tuned for the rated conditions, are presented in Table-3.2.. Table 3.2

Simulation of a Doubly Fed Induction Generator used in an Autonomous Variable Speed Hydro Turbine with Maximum Power Point Tracking Control.. 2006 12th International Power