Contact resistance problems applying ERT on low bulk density forested stony soils Is there a solution?

N/A
N/A
Protected

Academic year: 2021

Partager "Contact resistance problems applying ERT on low bulk density forested stony soils Is there a solution?"

Copied!
16
0
0

Texte intégral

(1)

Contact resistance problems applying ERT

on low bulk density forested stony soils

Is there a solution?

Deborah Deraedt1, Camille Touzé1, Tanguy Robert2, Gilles Colinet1, Aurore Degré1, and Sarah Garré1

(1) University of Liège, Gembloux Agro Bio-Tech, BIOSE, EESP, Gembloux, Belgium (2) AQUALE, Noville-les-Bois, Belgium

(2)

Aims

We use ERT (Electrical Resistivity Tomography) for 2

purposes:

1. To determine soil depth

2. To quantify

water fluxes heterogeneity

(3)

Where do we come from?

Equipmen

t

Site

Tracing

test

ERT Study

Forest

Terrameter

LS

No

DAS-1

No

Saline

tracer

Pasture

DAS-1

Saline

tracer

Equipmen

t

Site

Tracing

test

ERT Study

Forest

Terrameter

LS

No

DAS-1

No

Saline

tracer

Pasture

DAS-1

Saline

tracer

Equipmen

t

Site

Tracing

test

ERT Study

Forest

Terrameter

LS

No

DAS-1

No

Saline

tracer

Pasture

DAS-1

Saline

tracer

Forest

Terrameter

LS

(4)

Material & Methods

• Forest

– Belgian Ardennes

– Spruce and douglas mix

– 30 years old

– Silty soil with high stone content (surface average : 45%)

– Low bulk density (surface average : 1.25g/cm³)

(5)

Material & Methods

• Forest

– Terrameter LS

Electrodes layout :

Two types of configurations tested:

Single array

Dipole-dipole

Wenner-Schlumberger

6.3 m

(6)

Material & Methods

• Forest

– DAS-1

Electrodes layout : Configurations tested : 5 arrays (2*2m, 1*3m, 2*2m) Dipole – Dipole Wenner-Schlumberger Wenner Alpha 49 electrodes

(7)

Material & Methods

Equipmen

t

Site

Tracing

test

ERT Study

Forest

Terrameter

LS

No

DAS-1

No

Saline

tracer

Pasture

DAS-1

Saline

tracer

(8)

Material & Methods

• Pasture

– Central Belgium

– Silty soil

– Low stone content

(<2%)

– Bulk density

(1.4g/cm³)

(9)

Material & Methods

• Pasture

– DAS-1

Electrodes layout :

Configurations : 5 arrays (2*2m, 1*3m, 2*2m) Dipole – Dipole Wenner-Schlumb. Wenner Alpha

(10)

Material & Methods

Tracing

test

Equipmen

t

Site

Tracing

test

ERT Study

Forest

Terrameter

LS

No

DAS-1

No

Saline

tracer

Pasture

DAS-1

Saline

tracer

Saline

tracer

(11)

Material & Methods

• Tracing test

(12)

Equipment Tracing Site Contact Resistance (Ω) Should be < 3000 Ω Terrameter LS No 1 x Forest

Results

Equipment Tracing Site Contact

Resistance (Ω) Should be < 3000 Ω

Terrameter

LS No 1 x Forest

New ERT

device DAS-1 NoYes 1 x Pasture2 x Forest 750 – 170013100 – 51000

Equipment Tracing Site Contact

Resistance (Ω) Should be < 3000 Ω

Terrameter

LS No 1 x Forest

New ERT

device DAS-1 NoYes 1 x Pasture2 x Forest 750 – 170013100 – 51000 Drilled holes

+ Water DAS-1 No 1 x Pasture1 x Forest 670 – 16009800 – 32800

Equipment Tracing Site Contact

Resistance (Ω) Should be < 3000 Ω

Terrameter

LS No 1 x Forest

New ERT

device DAS-1 NoYes 1 x Pasture2 x Forest 750 – 170013100 – 51000 Drilled holes

+ Water DAS-1 No 1 x Pasture1 x Forest 670 – 16009800 – 32800 Drilled holes

(13)

Results on the pasture

Wenner Alpha

&

Wenner Sclumberger

data

(14)

Equipment Tracing Site Contact Resistance (Ω) Should be < 3000 Ω Terrameter LS No 1 x Forest New ERT

device DAS-1 NoYes 1 x Pasture2 x Forest 750 – 170013100 – 51000 Drilled holes

+ Water DAS-1 No 1 x Pasture1 x Forest 670 – 16009800 – 32800 Drilled holes

+ Mud DAS-1 NoYes 1 x Forest3 x Pasture 11700 – 325001600 – 2700

Results

Equipment Tracing Site Contact

Resistance (Ω) Should be < 3000 Ω

Terrameter

LS No 1 x Forest

New ERT

device DAS-1 NoYes 1 x Pasture2 x Forest 750 – 170013100 – 51000 Drilled holes

+ Water DAS-1 No 1 x Pasture1 x Forest 670 – 16009800 – 32800 Drilled holes

+ Mud DAS-1 NoYes 1 x Forest3 x Pasture 11700 – 325001600 – 2700 Drilled holes

+ Mud + CaCl2 DAS-1 No 1 x Forest 5200 – 15600

Equipment Tracing Site Contact

Resistance (Ω) Should be < 3000 Ω

Terrameter

LS No 1 x Forest

New ERT

device DAS-1 NoYes 1 x Pasture2 x Forest 750 – 170013100 – 51000

Drilled holes

+ Water DAS-1 No 1 x Pasture1 x Forest 670 – 16009800 – 32800

Drilled holes

+ Mud DAS-1 NoYes 1 x Forest3 x Pasture 11700 – 325001600 – 2700

Drilled holes

(15)

Problem

How to fix the contact resistance problem in the

forested soil??

As a reminder :

– High stone content in the top soil (45% in average)

– Low bulk density (surface average : 1.25g/cm³)

– Rather dry soil all year round

(16)

Thank you for your attention

Any question or suggestion?

Références

Documents relatifs

Donc, le facteur constant de Shellsort peut être n’importe quelle valeur plus petite que 32 fois que celle du tri par insertion, pour que l’algorithme de tri de Shell soit plus

Montrer que le mécanisme est compatible avec l’ordre expérimental déterminé et exprimer la constante de vitesse k en fonction des constantes de vitesse k i

Nesta actividade, você vai olhar para uma gama de software dinâmico disponíveis para apoiar o ensino e a aprendizagem da matemática!. Você vai avaliar os diferentes tipos de software

Mais cela ne préjuge pas d'une absence de limite pour la suite ( ) w n. Pour lever l'ambiguïté, nous allons factoriser la somme w par le terme qui nous n semble plus fort 9..

Uma parte do programa de Ciências para o Ensino Fundamental diz respeito ao conteúdo de Física, e para o seu desenvolvimento procuramos planejar atividades de conhecimento físico

totalité d’un système thermodynamique et dont les frontières peuvent être traversées par de la masse, de la chaleur, du. travail et/ou de la quantité

Sent esquecer as medidas jA tomadas atrav( s do Decreto- Lei n.o 234/93, d e 2 de Julho, para a melhoria das estruturas do sistema o6cial portugu&amp;s para os

por um lade, os custos das comunicac6es ir5o baixar para o mesmo volume de trdfego, quer por via da evoluc5o das tarifas quer peta oferta de novos servicos de