Time varying elastance estimation in an 8 chamber cardiovascular system model

Thomas Desaive1,2, J. Geoffrey Chase3, Christopher E. Hann3, David Stevenson3, James Revie3, Bernard Lambermont2, Philippe Morimont2, Alexandre Ghuysen2, Philippe Kolh2, Pierre C. Dauby1, Geoffrey M. Shaw4

1

Institute of Physics, University of Liège, Belgium. 2

Hemodynamics Research Laboratory, University of Liège, Belgium. 3

Centre of Bioengineering, University of Canterbury, Christchurch, New Zealand. 4

Department of Intensive Care Medicine, Christchurch Hospital, Christchurch, New Zealand. Introduction: Time-varying elastance curves are a common means of characterizing left and right ventricle function [1]. However, assessing elastance requires a highly invasive vena-cava occlusion maneuver and left and right ventricle pressure/volume waveforms, which are not typically available in an intensive care unit (ICU) and may raise ethical issues in regular use. A validated, lumped-parameter 8 chamber cardiovascular system (CVS) model is used to evaluate a time-varying elastance estimate at the bedside using standard clinical measurements.

Objectives: To assess time-varying elastance at the bedside for the left and right ventricles using available ICU data, and prove the concept on a porcine model of pulmonary embolism.

Methods: Five pigs had pulmonary embolism (PE) induced via injection of blood clots over 4 hours, developing full PE in stages from a healthy state. At each state several data sets were taken (46 in total over 5 pigs), measuring aortic and pulmonary artery pressure waveforms (Pao(t), Ppa(t)), left and right ventricular volume and pressure waveforms (Vlv(t), Vrv(t), Plv(t), Prv(t)).

At each cardiac state in inducing PE, the time-varying elastances are estimated as Elv=Plv/Vlv and Erv=Prv/Vrv. These values are correlated to readily measured quantities (Pao and GEDV). These correlations are used to approximate time-varying elastances Erv* and Elv* for use in a clinically validated 8-chamber CVS model. Note these approximations are load dependent and thus change with cardiac state.

A five-fold cross validation was used to validate the model. A time-varying elastance is generated from data from 4 pigs and used to simulate the fifth pig. Simulated PV loops are compared to the originally measured PV loops to validate the approach.

Results: Pao(t) and Elv were highly correlated over the 46 data sets (R=0.81 to R=0.99). Pao(t) and

Elv, GEDV and Erv are also well correlated (R=0.73 to R=0.98). Using the five-fold cross validation, the median errors (of 46) in the correlation-based estimates (Elv*, Erv*) of Elv and Erv to the measured ratios are 1.32% and 2.5% [90th percentile: 3.67%, 9.43%]. Simulated left and right ventricle PV loops have median errors of 8.3% and 7.0% [90th percentile: 11.5%, 13.1%] from measured values.

Conclusions: Left and right ventricle elastance curves can be estimated using typical ICU measurements of aortic pressure and global end-diastolic volume at any time or given cardiac state. With the addition of SV and pulmonary artery pressure measurements, this CVS model can accurately predict ventricular PV loops and thus ventricular function at the bedside. These results are the basis of an ongoing clinical trial in human subjects.

Reference:

[1] Segers P, Steendijk P, Stergiopulos, N, Westerhof N (2001). Predicting systolic and diastolic aortic blood pressure and stroke volume in the intact sheep. Journal of Biomechanics 34: 45-50.

Références

Documents relatifs

Multijunction photovoltaics: integrating III–V semiconductor heterostructures on silicon Olivier Durand, Samy Almosni, Charles Cornet, Antoine Létoublon, Christophe Levallois,

The paper has presented a multiple agent logic and outlined its possibilistic extension that enables a rich handling of inconsistency both in terms of subsets of agents and in terms

Outre cet effet érythropoïétique, l’EPO module la réponse ventilatoire à l’hypoxie (RVH) par une action directe sur la commande centrale respiratoire (CCR) et les

3 The clock function returns the implementation’s best approximation to the processor time used by the program since the beginning of an implementation-defined era related only to

At the seasonal level, increases in sound production activities detected at La Revellata in 2012 and 2013 are similar to the pattern of spawning events observed in this species

La persistance de saignement intermenstruel (spotting) 3 mois après le début d’une contracep- tion estroprogestative peut aussi être liée à une prise irrégulière, une infec-

Mais au-delà de leur fonction de canal de communication, les médias sociaux peuvent aussi être des outils à part en- tière pour promouvoir la santé et ainsi assumer une place

From 2003 to 2018, net runoff controls the largest variability in rates of biennial mass change (±61 to 69 Gt year −1 of ±83 to 98 Gt for SMB-D*), indicating a high sensitivity of