Unless otherwise noted, the following definitions apply in error messages given in Tables 21 through 26:

Code Explanation

oplb Operational label of the device.

device Device type or physical device number.

The operator response to ! !UKEYlN is Code Mean i ng

S Continue

x

Abort

When an irrecoverable error occurs, the Utility program aborts. For an irrecoverable input/output error on OC or DO, the code in the abort message is the operational label of the device. For- other operational labels, the irrecover-able input/output message is written. Abort returns, due either to error or X operator responses, cause UT to appear in the abort message.

Table 21. I/O Error Messages

Message Meaning

BOT oplb, device !! UKEYlN An attempt has been made to backspace over the magnetic tape load point or the beginning-of-tape of a RAD file.

CAL SEQ ERR The Uti lity Executive has encountered a calling sequence error on a return from M:READ/M:WRITE. One reason may be an attempt to copy a record with an odd byte count onto the RAD (may occur with BCD 7-track tapes).

See M:READ status returns in Chapter 4 of this manual.

EMPTY oplb, device !! UKEYlN Manual intervention is required (the device is in the manual mode or no device is recognized).

EOF oplb, device!! UKEYIN An unexpected tape mark, end-of-file (RAD), or !EOD has been read from magnetic tape, cards, paper tape, keyboard/printer, or RAD fi Ie.

EaT oplb, device!! UKEYIN The end-of-tape mark on a magnetic tape or RAD file has been sensed.

Utility Error Messages 111

Table 21. I/O Error Messages (cont.)

Message Meaning

IL RAD SEQ oplb, device J JUKEYIN An operational label was assigned to a random-access RAD file, or an attempt was made to skip, read, or write more than one RAD file.

INV I/O OP oplb, device! !UKEYIN An input/output operation is not meaningful for the requested device.

INV OPLS oplb, device J !UKEYIN The operational label is not valid. The "oplb, device" portion of the message may contain invalid data if input/output is attempted for an operational label not recognized by the Monitor.

I/O ERR oplb, device

I

The input/output calling sequence is in error, incorrect length is

. f '

. . .

,

.

I I TI

specmea, or no mpur/outpur IS penamg for a cneCK operation. I ne

"'

...

/ .-~.-

...

_ _ ,1.., ..

II.; I :." p .. "" .. " ... ah" ... "

UNRECOV I/O oplb, device! !UKEYIN An irrecoverable input/output error has occurred after the maximum number or retries has been unsuccessfully attempted.

WRITE PRO oplb, device! !UKEYIN An attempt has been made to write on a write-protected magnetic tape or RAD file.

Table 22. Control Function Command Error Messages

Message Meaning

FSKIP Command

DEOF oplb, device! !UKEYIN Two consecuti ve fi I e marks were encountered before the requi red number of fi I es had been passed.

EOT oplb, device! !UKEYIN

I

The end-of-tape was encountered before the required number of files has been passed.

I L RAD SEQ oplb, device!! UKEYIN The number parameter is not 1 and "oplb" is assigned to a sequential-access RAD file, or the oplb parameter is assigned to a random-sequential-access

RAD file.

INV OPLS ! !UKEYIN The operati ona I label identifies an invalid device.

PARAM ERR! !UKEYIN The oplb parameter is missing, or the number parameter is nonnumeric or greater than 32, 767.

RS KI P Command

EOF oplb, device !! UKEYI N An !EOD or file mark was encountered before the required number of records was passed.

EOT oplb, device! !UKEYIN An end-of-tape was encountered before the specified number of records was skipped.

IL RAD SEQ oplb,device I !UKEYIN The oplb parameter is assigned to a random-access RAD file.

INV OPLS !!UKEYIN The oplb parameter identifies an invalid device.

I

PARAM ERR! !UKEYIN The oplb parameter is missing, or the number parameter is nonnumeri c or greater than 32, 767.

112 Util ity Error Messages

Table 22. Control Function Command Error Messages (cont. )

Message Meaning

FBAC K Command

BOT oplb, device llUKEYIN The beginning-of-tape was encountered before the required number of fi I es had been passed.

DEOF oplb, device llUKEYIN Two consecuti ve fi I e marks were encountered before the requi red number of files was backspaced.

IL RAD SEQ oplb,device I !UKEYIN The opl b parameter was assi gned to a random-access RAD fi I e.

INY OPLB oplb, device I !UKEYIN The operati ona I label identifies an invalid device.

PARAM ERR I I UKEYIN The operational label parameter is missing or contains more than two characters, or the number parameter is nonnumeric or greater than 32,767.

RBAC K Command

BOT oplb, device llUKEYIN The beginning-of-tape was encountered before the requested number of records had been passed.

EOF oplb, device I !UKEYIN A file mark was encountered before the requested number of records had been passed.

I L RAD SEQ oplb, device I I UKEYIN The oplb parameter was assigned to a random-access RAD file or a compressed EBCDIC RAD file.

INY OPLB oplb, device llUKEYIN The operational label identifies an invalid device.

PARAM ERR llUKEYIN The operational label parameter is missing or contains more than two characters, or the number parameter is nonnumeric or greater than 32,767.

REWIND Command

IL RAD SEQ oplb,device llUKEYIN The oplb parameter is assigned to a random-access RAD fi Ie.

PARAM ERR I !UKEYIN The oplb parameter contains more than two characters.

UNLOAD Command

IL RAD SEQ oplb, de,vice llUKEYIN The oplb parameter is assigned to a random-access RAD file.

INY OPLB oplb, device!! UKEYIN The oplb parameter identifies an invalid device.

PARAM ERR! lUKEYIN The oplb parameter was missing or contained more than two characters.

WEOF Command

EOT oplb, device!! UKEYIN The end-of-tape was encountered.

IL RAD SEQ oplb, device ! lUKEYIN The oplb parameter was assigned to a random-access RAD file.

INYOPLB !!UKEYIN The oplb parameter identifies an inval id device.

PARAM ERR llUKEYIN The oplb parameter is missing.

Uti I ity Error Messages 113

Table 22. Control Function Command Error Messages (cont. )

Message Meaning

PRESTORE Command

CORE OVFLO Available core memory has overflowed. The Util ity program aborts.

PRE ERR!! UKEYIN The ! *PRESTORE command did not follow immediately after the ! *UTI LITY command.

I

PRE OVFLO The RAD prestore file on X5 has overflowed. The Uti I ity program aborts.

ASS} GN Command

ERR FRGD ! !UKEYIN An attempt has been made to assign a background operational label to a

I

foreground operational label, device-file number, or RAD file.

ERR OPLB 1 !! UKEYIN The operational label to be assigned is invalid.

ERR OPLB2 !!UKEYIN An attempt has been made to assign one operational label to an invalid or undefined operational label or RAD file.

NO SPARES! !UKEYIN An attempt has been made to define a new background operational label but no room is available in the corresponding table".

ERR AREA! !UKEYIN An inval id RAD area name has been used.

OPLB TABLE OVFL ! !UKEYIN An attempt has been made to define more than eight LJnique operational labels. The assign wiJl be successful, but the operational label will not be used as on output device.

Table 23. COpy Error Messages

Message Meaning

CORE OVFLO The memory area used for storing input records (when the CORE option on the !UTIUTY COpy command is used) has overflowed. The Utility pro-gram aborts.

IL RAD SEQ oplb,device ! IUKEYIN An attempt has been made to copy or verify from or to a random-access RAD file.

OPLB TABLE OVFL ! !UKEYIN An attempt has been made to input more than eight operational labels.

Only the first eight unique labels on an ! *OPLB card will be entered in the operational label table.

{DEOF oplb, device } An end-of-tape, or two consecutive tape marks or !EODs were detected EOT oplb, device ! !UKEYIN on X4 or UI before the number of fi I es requested has been compared.

EOF oplb, device ! !UKEYIN An !EOD or file mark was detected on X4 or UI before the number of records requested had been compared.

VERIFY ERR oplb, device An error has been found by the verification process. When a verification error occurs, the COpy routine terminates execution of the ! *VERIFY

I command for that device, but continues verification on other input

I

I

devices. if an error is detected on every input device, the VERiFY function is aborted.

114 Uti! ity Error Messages

Table 24. Object Module Editor Error Messages

Message Meaning

BLNK NAME oplb,device !! UKEYIN A blank name was input.

CKSM ERR oplb,device !! UKEYIN A checksum error was detected on a record read from UI or BI.

EOT oplb,device ! ! UKEYIN An end-of-tape was encountered on BI or UI.

ILLEG BIN oplb,device !! UKEYIN The fi rst byte of a record read from UI or BI did not contain X'FF' or X '9F'.

NO name oplb,device ! ! UKEYIN Two consecutive! EODs or tape marks on UI, or one! EOD or tape mark on BI were encountered during the editing process before the desired number of modules had been copied (where "name" is the program name not found).

NO name UI,device !! UKEYIN Two consecutive !EODs or file marks (one end-of-file for a sequential-access RAD fi Ie) are read from UI before the Object Module Editor has inserted, replaced, or deleted all requested modules.

SEQ ERR oplb,device !! UKEYIN A sequence error was detected ina record read from UI or BI.

Table 25. Record Editor Error Messages

Message Meaning

! ! LD LIST UI,device Both SI and UI are assigned to the same device. The operator responds by mounting the tape to be listed and changes the state of the device.

LD INPUT UI,device ! ! UKEYIN The modify mode was entered and updati ng is to be performed. The operator responds by mounti ng the tape to be input and keying-in an S response on OC to continue.

INV CTRL ! ! UKEYIN A ! *MODIFY control command was interpreted from SI when the Record Editor was not in the modify mode.

Uti I ity Error Messages 115

Table 26. Sequence Editor Error Messages

Message Meaning

DELETE ERR!! UKEYIN No UI card images were found in the block to be deleted {for! *DELETE and ! *SUPPRESS commands}.

DEOF UI,device ! ! UKEYIN

i The program to be updated was not encountered on the input tape before

I the logical end-of-tape. An S response causes the Sequence Editor to

I

return to RBM. All updating done prior to this point has been written, along with the logical end-of-tape marker on the output tape.

PA"RAM ERR!! UKEYIN Case 1. Update data from SI contains an illegal sequence number; that

I

is, a nonnumeric character. An error alarm is also listed on LO.

I

Case 2.

- - -

A necessary control command parameter was omitted.

I I

Case 3. The ident parameter {on an !*IDENT card} is greater than 6, the

I

- - -

sequence number parameter is less than 2, or the sum of the two parameters is greater than 8~

SEQ ERR oplb,device !! UKEYIN A sequence error was found in either the update data or input tape. In this case, the oplb parameter refers to either SI or UI. An error alarm is also listed on LO.

UNRECOV I/O UI,device ! ! UKEYIN An irrecoverable read error has occurred on UI. The partial card image input and the message II UI IGNORED RECORD FOLLOWS XXXXXXXXIl

{when xxxxxxxx is the previous nonblank UI ident and/or sequence number} is output on LO.

UNRECOV I/O UO,device ! ! UKEYIN An irrecoverable write error has occurred on UO. The card i mage to be output, and the message II UO RECORD OMITTEDII or II UO FILE MARK OMITTEDII, are output on LO.

116 Util ity Error Messages

10. PREPARING THE PROGRAM DECK

The following examples show some of the ways program decks may be prepared for RBM operation. Unless stated otherwise, standard default cases for device assignments are assumed.

Dans le document Xerox Real-Time Batch Monitor (RBM) Sigma (Page 123-129)