MISCElLANEOUS COMMANDS

Dans le document Xerox Control Program-Five (CP-V) (Page 88-92)

ALL

'J

bank = n[, NO)

where ALL

unit

unit ,bank

specifies that the threshold value on ALL banks Is to be set to n.

specifies that the threshold value

Is

to be set to n for the specified unit. Posslbl.

values are 0 and 1.

bank specifies that the threshold is to be set to n for the specified bank. Possible values are the letters A-D .If unit is not specified, unit 0 is assumed.

unit, bank specifies that the threshold value Is to be set to n on the specified bank (A-D) In the specified unit (0-1).

n is the number of errors to report before RCE is set off for the selected elements.

O~ n

S.

255.

NO specifies tJoat the "current" value Is not to be chaned for the speci ft ed bank/

unit. If not specified, the current count is set to zero.

'In any case, an attempt is made to turn RCE ON after the threshold value is changed. However, If the threshold :volue is less than or equal to t"-e current value, RCE Is 'not activated on the bank that falls the comparison.

90 16 74H-2(9/78)

RCE This command specifies whether or not SBCEs are to be reported. The form of the command is

RCE [ ] [

,ALL

1

ON ,bank OFF lun~t

I unit ,bank where

ON specifies that SBCEs are to be reported on the specified element.

OFF specifies that SBCEs are not to be reported on the specified element.

ALL bank

I

unit unit, bank

Are the some as described for the THRESHOLD command.

Execution of this command prints a CURRENT status for the speclfled elements. Note that setting RCE on for an ele-ment when tts current value is equal to or greater than its threshold value results in RCE OFF for that element.

END This command specifies that control is to exit the MOS sub-command level and return to the command

level of con~rol.

MISCElLANEOUS COMMANDS

QUIT

This command may be given after a BREA K com-mand to terminate the interrupted session. If issued, the interrupted environment wi II be lost and execution wi II continue at the control command level. The format of the command is

QU[JT]

Control

72.1

PROCEI::D This command returns control to the partition sub-command level fol/owing an interruption. If no inter-ruption has occurred (BREA K key has not been depressed) and execution is at the control command level, the mes-sage" NO BREA K ISSUED" wi" be output and a prampt for a new command wi

1/

be issued. The format of the com-mand is

PR~OCEED)

An example of the PROCEED command is given in Figure 10.

BREAK At the confrol command level, depressing the BREA K key may serve to interrupt a lengthy display. After the first BREAK is issued, subsequent BREAKs are ignored by Control. Four successive BREAKs return control to TEL.

END At the control command level, this command causes an exit from the Control processor and returns con-trol to TEL. The format of the command is

EN[DJ

An example of this command is given in Figure 11.

TIME This command displays the time of day in hours and minutes. The format of the command is

TI[ME)

I

72.2 Control

Example:

-TIME ~I)

12:32

SAMPLE COMMAND SEQUENCE

The command sequence in Figure 12 shows how the Control program may be used to modify control va lues and to dis-play and modify partition attributes.

CONTROL ERROR MESSAGES

The Control processor wi II return an error message to the terminal whenever a command is entered incorrectly. The error messages are listed in Table 21.

CONTROL COMMAND SUMMARY

Table 22 contains a summary of the control leve.1 commands for the Control processor. Table 23 contains a summary of th,~ partition subcommand level commands for the Con-trol processor. In both tables, the left-hand column speci-fies the format and the right-hand column defines the function.

90 16 74H-2(9,178)

!CONTROL @) (cal!!; CONTROL program) CONTROL HERE

.:..ADD @) (requests that itern dIsplay flags be set)

.!,.TB

e

(sets TB display flag)

(sets UB display flag) (exits from ADD routine)

.:.CO@> (displays items with flags on)

_1I_C_HA_R_S._T_E_R_M_I_NA_L_B_L_OC_K _ _ <:.-T;.,;;.BL>_'"'_4_0 ______ it CHARS TERMINAL UNBLOCK .... <UB).:._~LO

.:.TB = 60

09

(sets value of TB I~o 60)

.:.PART ~9 (en ten partition c:ommand level)

2:D1 ALL @) (displays all partition attributes)

: PART TIME QlJAN LOCK HOLD CUR TOL CO

---_._----

7T 9T SP

1 0-5 400 NO YES 25 211 0-15 0-0 0-0 0-0

2 0-15 450 NO NO 13 77 0-32 0-0 0-2 0-1

-=:;..3 _ _ -=-15=---=6:....:0_---=5:....:0...:.0--=N..:....0:...--.:N::.;..0~_7~--=-1..:....4 --=1:....:6_"'\~6 3 0 -0 0 - 3 0-2

4 6-15

.:.PR @

2:4 LOCK = 0 @) 2:STORE @)

VALUES STORED 2:END @)

.:.END @)

600 YES YES 0 3 16-32 0-0 O~O 0-0

(interrupts partition display session)

(calls for time t·o be displayed)

(proceeds at partition command level) (sets LOCK attribute of partition 4 to 0:= No) (in effect, opens partition 4 for schedul i n9) (store-s attribute in partition table)

(exits. from partition command level) (exits. from CONTROL)

Figure 12. Sample Command Sequence

Control 73

Table 21. Control Error Messages

Message Description

'CURRENT ' VALUES MAY NOT BE An attempt was made to set a current value (see Table 17).

ALTERED Current values may only be, displayed.

ILLEGAL COMMAND The command verb was not recognized by Control. Reenter the comma ncI •

INVALID NUMBER The value of the control parameter is invalid. Reenter the control parameter name and the correct value.

I/o

ERROR AT xxxxx THROUGH M:XX DCB An ERR/ABN return occurred while reading through the Imessage from ERRMSG file corresp'nding to M:SI DCB or writing through the M:LO or M:DO DeBs.

ABN codel I/O SUBROUTINE CALL AT xxxxx Input and output will be reassigned to the default devices for this type of job if set to other devices. Otherwise an abort wi II occur.

-LIMIT CHANGE REQUIRES The user does not have prlvi lege level of at least X ICOI AT LEAST PRIVILEGE CO which is required to modify system limits.

MONITOR ACCESS REQUIRES The user does not have a prlvi lege level of at least X

1801

AT LEAST PRIVILEGE 80 which is required to display monitor tables.

NO BREAK ISSUED An attempt was made to QUIT or PROCEED when no BREAK was active.

NO SUCH ATTRIBUTE The partition attribute specified In the command does not exist.

\

NO SUCH CONTROL NAME An attempt was made to change a performance parameter or to ADD or DROP a display Item that does not exIst or Is In-correctly represented.

NO SUCH PARTITION The partition number specified In the command Is out of the range 1-16 or refers to a nonexistent partition.

.

NUMBER NOT WITHIN LEGAL RANGE The value of the control parameter is outsIde of the legal PERMISSIBLE RANGE

=

xx-xx range. Reenter the command with a legal controL parameter

value (see Table 16).

PARTITION ATTRIBUTE DEFINITION The user does not have a privi lege level of at least X ICOI REQUIRES AT LEAST PRIVILEGE CO. whfch Is required to change partition attribute definitions.

PARTITION CONTROL ACTIVE An attempt was made to reopen partition control without terminating the previous command session.

PARTITION CONTROL ACTIVE The user has attempted to reenter the partition subcommand

-QUIT, PROCEED, OR CONTROL COMMAND level after having interrupted a previous partitil")l1 rommand level session with a break. He must resume the p.revious session, quit it, or issue a control level command.

SAD CAL FAILURE IN I34MApl- An internal assembly problem exists. See system analyst.

REASSEMBLE

SYSTEM NOT GEN'ED FOR THAT An attempt was made to change or to display a control

pa-CONTROL NAME rameter for which the running system was not SYSGENed.

***.

A numeric overflow occurred on CONTROL or CONTROll

display of a system control parameter. The parameter wi II automatically be displayed as a single parameter display.

74 Control

Table 22. Control Command Summary (Control Level)

---Command Description

.•.

-AD(D] Turns on the print flogs for the specified items. Any item may be the Control

. item Name of any item In Tables 16 and 17 •

-.item

--

--BREAK (I.e.,

8)

Returns control to TEL if depressed four consecutive times. (May be used to interrupt a lengthy display by issuing once.)

----.

--CO[NTROL) Displays all parameters listed in Tables 16 and 17 that have their print flags on.

: CO[NTROL]~ Displays all parameters listed in Tables 16 and 17 whether or not their print flags are on.

-; -DR[OP) Turns off the print flags for the specified items. An item may be the Control

.. item Name of any item in Tables 16 and 17 •

-:-item

·

- .

--

.-EN[D) Causes an exit from the Control processor and returns control to TEL.

'.

· LI[STJ Lists the names of all items which have their print flags on.

· name Displays the specified parameter value. The name must be on item name from the lists in Tabl.,s 16 and 17.

name = value Sets the value of the specified contTol parameter. The name must be the Control Name of a control parameter and the value must be within the range for the parameter (see Table 16).

_

...

PR[OCEED] Returns control to the partition sub-·command level following an interruption.

If no interruption has occurred (BREAK key has not been depressed), on error message is output and execution returns to the control command level.

QU(IT) Terminates a previous session interrupted by a BREAK command and passes execution to the control level.

. TI[ME] Displays the time of day in hours and minutes.

--MO[S1 Turns control over to the MOS mem·ory sub-command display (with privilege of at least X'80') or modification (with at least

X'CO').

Sets the threshold value of the selected MOS memory element to n. If NO is

[ALL 1

specified, the current count is not changed.

;TH[.RESHOLD]

~:~tk

= n[, NO)

unit,bank

Displays the current MOS memory parameters for the selected elements.

[ ALL 1

:CU[RRENT]

ba~k

: unit

. unlt,bank

Sets the SBCE reporting for the specified elemenlt(s) ON or OFF.

Dans le document Xerox Control Program-Five (CP-V) (Page 88-92)