BUILDINGS AS SYSTEMS
SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREIENTS FOR THE DEGREE OF MASTER OF ARCHITECTURE AT
THE MASSACHUSETTS INSTITUTE OF TECHNOLOGY
A /)
PAUL SUN
B.A. TARKIO COLLEGE, MISSOURI 1957
B.ARCH. COLUMBIA UNIVERSITY 1963
LAWRENCE B. ANDERSON, HEAD
DEPARTMENT OF ARCHITECTURE
MASSACHUSETTS INSTITUTE OF TECHNOLOGY
MASSACHUSETTS INSTITUTE OF TECHNOLOGY
JUNE 1966
LAWRENCE B. ANDERSON, DEAN
SCHOOL OF ARCHITECTURE AND PLANNING MASSACHUSETTS INSTITUTE OF TECHNOLOGY
DEAR DEAN ANDERSON :
IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE
DEGREE OF 4ASTER IN ARCHITECTURE, I HEREBY SUBMIT
THIS THESIS ENTITLED " BUILDINGS AS SYSTEMS "
RESPECTFULLY,
ABSTRACT
THE AIM OF THIS THESIS IS TO DESIGN BUILDINGS AS SYSTEMS --- A SYSTEM OF GROWTH, A SYSTEM OF
ADAPTABILITY, A SYSTEM OF STRUCTURE.
A SYSTEM TO BE APPROACHED AS AN ORDERLY ORGANIZATION
OF COMPONENTS INTERACT WITH EACH OTHER TO RECEIVE
MAXIMUM UTILIZATION FROM EACH AND FROM THE WHOLE.
A SYSTEM TO BE CREATED FOR BUILDINGS A NEW SCALE
WITH EMPHASIS ON SPATIAL QUALITY AND INTERNAL LIFE.
A BUILDING NEED NOT GROW OBSOLETE, THEY CAN GROW INTERNALLY
ACKNOWLEDGEMENTS THESIS SUPERVISOR EDUARDO F. CATALANO STRUCTURE WARCKW ZEWLESKI MECHANICAL EQUIPMENT SIDNEY GREENLEAF
TABLE OF CONTENT TITLE PAGE --- 1 LETTER OF SUBMISSION --- 2 ABSRACT ---
3
ACKNOELEDGEMENTS- ---4
TABLE OF CONTENTS ---5
LIST OF ILLUSTRATION --- 6 INTRODUCTION --- 7 SPACE --- 8 STRUCTURE --- 10 MECHANICAL EQUIPMENT --- 11 CONSTRUCTION SEQUENCE --- 12ELECTRICAL, LIGHTING, ACCOUSTICAL AND PARTITION - 13
LIST OF ILLUSTRATION
1. BUILDINGS AS SYSTEMS - EDGE CONDITION
2. SYSTEM OF GROWTH AND ADAPTABILITY - FOOTPRINT
3.
SYSTEM OF SPATIAL FLEXIBILITY - SECTIONS4.
PLAN - STRUCTURAL MODULE, CORE, REFLECTED CEILING PLANAND MECHANICAL DUCT SYSTEM
5.
CONSTRUCTION SEQUENCE 6. STRUCTURAL SECTION I 7. STRUCTURAL SECTION II PHOTOGRAPH OF MODEL A. GIRDER B. BEAM I 0. BEAM II D. STRUCTURE I E. STRUCTURE II F. STRUCTURAL VOID I G. STRUCTURAL VOID IIINTRODUCTION
TO DESIGN BUILDINGS WITH A SYSTEM OF GROWTH BOTH
INTERNALLY AND EXTERNALLY. MUST ALSO PROVIDE
FLEXIBILITY - PRESENT AND FUTURE.
TO ESTABLISH A FOOTPRINT OF STRUCTURAL AND MAIN MECHANICAL CORE OR BRANCHES AS PERMANENT ELEMENTS
OF THE SYSTEM, WHILE ACHIEVE FLEXIBILITY FOR SECONDARY STRUCTURAL AND MECHANICAL COMPONENTS THAT CAN CHANGE OR BE REMOVED PRESERVING THE
SPACE
THE SPACE-FLEXIBILITY SYSTEM PROVIDES FOR MAXIMUM INTERNAL FLEXIBILITY BY MOVING MODULAR PARTITION SPACINGS. AN
ORDER OR CONTROL OF THE PARTITION ACCOMPLISHED BY ESTABLISHENG A GRED UPON WHICH TO BUILD PARTITIONS. ALL SPACE WILL THEN
GROW IN INCREMENTS OF THE BASIC UNIT OF THE GRID : THE MODULE.
A MODULE OF
4'X
8' WAS SELECTED ON THE FOLLOWING PREMISES :1. SMALLEST DESIRABLE WIDTH FOR CORRIDOR CIRCULATION 8'
2. BASIC INDIVIDUAL SPACE 8'X 12'
5.
FLEXIBLE SPACING FOR LIGHT-DIFFUSER UNITS.4.
32'X32'
BAY A MULTIPLE OF THE MODULE IS DESIGNED FORTHE CORE AND A GOOD PARKING BAY SPACING.
5.
64'X64' A MULTIPLE OF THE MODULE PROVIDES MAXIMUMFLEXIBILITY IN SIZE OF SPACES AND SIZE OF VOIDS.
TO ESTABLISH THE UNIFORM DEPTH OF EXPOSED BEAM AND GIRDER TO FORM A LOGICAL AND SOUND CONSTRUCTION TERMINATION FOR PARTITION.
THE CORES ARE DESIGNED TO BE MULTIPLES OF THE ESTABLISHED
STRUCTURAL BAY. THERE ARE TWO TYPES OF CORE, ONE HOUSES
SPACE AND THE OTHER HOUSES STAIRS, TOILETS AND MECHANICAL
DUCT SPACE. THIS DUAL CORE SYSTEM ACHIEVES LARGER FLOOR
AREA UNDER EGRESS CODE RESTRICTION AND DIVIDES MECHANICAL
MAIN DISTRIBUTION TO REDUCE DUCT SIZE IN TURN REDUCES
STRUCTURAL OPENNINGS. THE CORES THEN BECOME PART OF THE
SYSTEM AND DO NOT INTERRUPT THE INTEGRITY OF THE STRUCTURAL SYSTEM. THE DUAL CORE DESIGN ALSO PROVIDES FLEXIBILITY IN SYSTEM OF GROWTH IN SMALLER INCREMENTS. THE POSITIONING
OF THE CORES ESTABLISHES THE MAJOR HORIZONTAL CIRCULATION PATTERN, MAJOR MECHANICAL DISTRIBUTION CHANNEL AND BUILDING CODE REQUIREMENTS.
PAIRED RECTANGLE COLUMNS LOCATED AT THE SAME DIRECTION OF
THE MAJOR GIRDER EMPHASIS THE ONE WAY SYSTEM, IT ALSO REDUCED
THE MASS OF THE COLUMN. THE OPENNING AT COLUMNS ALSO
EMPHASIS THE LOCATION OF MIXING BOXES AND THE SECONDARY
CHANNEL FOR MECHANICAL DUCTS, IT IS POSSIBLE TO INDICATES
STRUCTURE
ONE-WAY SYSTEM WITH A MODULE OF 4'X8'.
GIRDERS : 12" X
36"
REINFORCED CONCRETE, SPAN 32'NO OPENNINGS.
BEAM I : 6" X 36" PRECAST CONCRETE, SPAN
32'
WITH 12" X 48" OPENNINGS CARRYING MAJOR
MECHANICAL SUPPLY AND RETURN DUCTS. BEAM II ; 6" X
36"
PRECAST CONCRETE, SPAN 64'WITH 12" X 24" OPENNINGS CARRYING LOCAL
DISTRIBUTION DUCTS.
COLUMNS : 12" X 42" REINFORCED CONCRETE POURED,
IN PAIR SBACED WITH A NOMINAL DIMENSION OF
ONE MODULE. PROVIDED OPENNINGS BETWEEN COLUMNS FOR
SECONDARY MECHANICAL DISTRIBUTION CHANNEL.
MECHANICAL EQUIPMENT
DUAL DUCT HIGH VELOCITY MAIN SUPPLY AT THE CORE. ALL UTILITY-SERVICE LINES ARE TERMINATED IN A
SUB-BASEMENT AND EXTEND TO THE ROOF OFFERING VERTICAL EXHAUST.
THE COOLING TOWERS ARE LOCATED ON THE TOP OF EACH CORE.
THE BOILERS, FAN ROOMS AND REFRIGERATION EQUIPMENT ARE
LOCATED IN A SUB-BASEMENT MECHANICAL ROOM.
THE PRIMARY HORIZONTAL AIR SUPPLY AND RETURN IS LOW VELOCITY AND LOCATED IN THE STRUCTURAL CAVITY ABOVE. MIXING BOXES ARE LOCATED AT EACH COLUMN SPACING OF
321
AND THE OPENNING FOR SECONDARY SUPPLY AND RETURN CHANNEL.
ALL HORIZONTAL LINES, SO AS NOT TO INTERFERE WITH THE
PARTITIONS, WILL BE HOUSED WITHIN THE STRUCTURAL DEPTH.
DUCT RUN THROUGH OPENNINGS AT BEAMS ONLY, NO OPENNINGS AT
GIRDERS.
EACH MODULE HAS A DIFFUSER-LIGHTING UNIT. EACH OTHER MODULE HOUSES A SUPPLY DIFFUSER AND EACH ADJACENT MODULE
A RETURN DIFFUSER. PROVIDE PLUG-IN CONNECTION OF SUPPLY OR
RETURN DIFFUSER FOR SPACE REQUIREMINTS.
THE PERIMETER ZONE AIR IS RE-HEATED OR RE-COOLED WITH
CONSTRUCTION SEQUENCE
POUR CONCRETE FOUNDATION
POUR IN PLACE CONCRETE COLUMNS
PLACING PRE-CAST GIRDER
WELDING CONNECTION AT COLU4N AND GIRDER WITH PRE- SET
STEEL PLATE CONNECTION. PLACING PRE-CAST BEAM1S
PLACING PRE-CAST CONCRETE DIAPHRAM AND LOCKED IN PLACE. PLACEING CONCRETE SLABS
PLACE UNDER FLOOR ELECTRICAL DUCT
POUR CONCRETE TOPPING OR ROOFING FINISH FLOORING OR ROOFING
PLACING MECHANICAL DUCT THROUGH STRUCTURAL CAVITY
PLUG - IN LIGHTING-DIFFUSER UNITS
ELECTRICAL
UNDER FLOOR DISTRIBUTION SYSTEM. SINGLE -LEVEL DUCT 1 7/16" x 6 5/8" RECESSED STAINLESS STEEL JUNCTION BOX
COVER AND TRIM RING FLUSH FLOOR OUTLETS.
LIGHTING
LIGHTING AND DIFFUSERS COMBINE. PLUG IN CONNECTIONS. SPACING AT EACH STRUCTURAL MODULE.
PARTITIONS
4'
X 8' REMOVABLE PARTITION PANNEL WITH BUILT-IN INSULATION.ACCOUSTICAL
MODULAR ACCOUSTICAL PANNELS PLACEED AT EACH STRUCTURAL
OPENNINGS AND AT SIDE OF PRE-CAST CONCRETE BEAMS.
'N N, K.. 4 1~ Ir 77 Ii II 'I, / ./, I I
97
7/f A'~I -7 1 9 /~
9
~14~j
~j~I 7/ ItN+++. +----uuhzt -:
..
-.. h . . . --- ::: -- - - ---11 1 t _________ .-.. , .. ... ,..7 ...1 ... .. .. .. .. .. .. ... .. .. .. .. .. .. .. .. tt,1:1'.
J771
+t--'
Jtj
:++t
t4- t - -I {:-::---..
. -4. t+++-1EV
1~~~~~~El):.
I-PAZ
.7-,77477.
rn47+
JulIIr1t
94~1I
I *- -!TT TtT ~IJiLi III I]]:::' I I IAt
4 - ""-c, ~-r~ r 1 yr 97< 2 +L+- -rti7wwi E-rt I ~ I . + + .- ---'-P5+ A
ii .1.t
+ + +-77I.[ 7V9 I MiT Ii I I , , I I . 1 ! 1 11111 UF IW 11[ 7 WY: !7->7T'J U I TrtT.I1..7...;C-""
'17
- ...ii..:r:...:::7 1.j::i21P7-jj-i:7I
'1j.L11E
22
----...++- - T. +...++ 4. .. .. --.. . . .--. . -.. . .-- - . . . ..- . . ---- --- t.. . .-- --.. . . .- ..-- -.. - --. -- - - --- --.-.-- -. -- - - ---.-.-.-. *I*.- .+++.-I-.+++.+.-.t.t. -. -b - -- - - * -- - - -T-v o id s.... I..I ... .... .... -4 -4 4 11 i i-- 1, ii i L i 't- I I I i I I I I , 0 7 TT-7 - 11 T' 7T .--- I I I - '' I i P H i i i i i i i --- I i I L i 4 - -- --I- - 1 1, 1 1 L iI I.
.
I -- I! i-L J - T, I 1! 1 1 i 1 1 'Ll , H A-1---I.iLj Ll qwl 41 11 R! i ?I I T, i ii i F TIT, I: 1 I i t i - - ! j - 71 ! 1 1 "- I -ij I !; 11 ri I11,
TT -Irlrl i i Tl---T-T 4 i ! 1 1 ! d 1 1 ; IT
HIL H h ! , '-, "1 1111 6 1 , U Trrlr-l |ET | | |---*---.-.
-.. -. .-. .CENTRAL VOID SECTIONAL ADAPTABILITY H- C-I I I -t :1 rr~ r I:
t-E DGt-E t -1
r7 -4r
0
0, a
01,
0701I o
U0
Oil0 No 0 B0
Io
U Uo~o jDJo'
U~~~~~~~~~ U'UUUjI
0
~~U
~U
~[
I-1il-am
7 12
MMMM mm! m sm iii-7 7",17
-
P
10UU U
~ElEl
U
UDLj[1
0
L
I'M,
E
H
I
E
l l
E
H
El
1D
El
if
if
El
El
EEl
El
El
if
if
Eli
ElTEl'~IEl1ElIEl~jElEl[El~EliElEl
El
ElElEl
ElElEl
IEHl: li
El
HElEl
ElEl
El
El
El
El
El
El El
El
E
Hl
oL LEL
l
l
El
j
El
ElEl
iI
El
EJHL
El
Th E
]
E
ElE
El El El8
4
El U
ElE
lE
lE l
ii
~1I
'0
17
fjo I ol
1040 0
10
lit
44+
~-";
liii r i 4" 4.-.. .4"L
I
I
LIL
01U0
U
10U o
UU0
10'
TU7Doo
flU~~~~~~
o[~'U~UU
U
UUUi o
1 IUUUU
10 UUU
#11010D01#1
Uj
Oil00100100UUUUUUUUUU11100U0U01
rUUUUU'UUUUJ
0i
D bUo
UUo
Uj
UoUUiU
U Uj U
I
4111
I r l7
*44 4* ~ 14~~1-
T 44, At7
'4
~L
iL~
i 11 4 1 11 i i ! i i 11 -6. w p N ii "r -+- + 4-4 ,-4 I I! 1 11 i H il w 11 A IL " -Irr -, r 7- T 11 I i i i w I i i ii P i ii H I H i h H ii H i I ii ii m iff V[U
L~I~1~
U~U1U~U U~U~U
U[U~U U~U
U flU
El
U
El
0
1.r
U
El
[0 T 0 r-I r"a
LLJ C3 -TIT~ 7LPRE-CAS UNIT
PERIMETE FAN COIL L
L'L
GIRDERS SECTION
BEAM CROSS SECTION
MECHANICAL DUCT SYSTEM
COLUMN CONNECTION
steel bars welded to recessed sleel plate
- PRIMARY AIR SUPPLY& RETURN CHANNEL
PARTITION
ELECTRICAL RACEWAY
UNITS-BEAM SECTION
MECHANICAL DUCT SYSTEM
STRUCTURAL CROSS SECTION
MIXING LOX
NOT & COLD DUAL DUCT MAIN SUPPLY
SUPPLY DUCT
-MAIN RETURN DUCT
-LIGHTING- DIFFUSER UNIT
UNDERFLOOR ELECTRICAL DUCT SYSTEM
connection
t
I'l
hi
U
--
U
U
-U-'414pokm
w
E-
lop"