DISTRIBUTION .

To Lists SA, RS, UA, UB, 174, 175, 176, 177, 178, 179, 184, 185,186 187,188, 189,}8A, 17 A • Memo & Attachments

INTERIM UPDATE

NOTICE

9200/9200 II 9300/9300 II

DATE JUNE, 1975

---.---

PRODUCT: 9200/9200II/9300/9:xJOII 8411/8414 DNCOS REVISION 5000 I

PHILADELPHIA DEVELOPMENT CENTER.

SOFTWARE DEVELOPMENT SUPPORT BLUE BELL, PA

,

.

\~

-j

(2)

~

...• \...r

,

'\ ..

_/

A. SOFTWARE UNIT: Rev.

DNCOS 8411/8414 Software 5.0.1

B. REASON FOR RELEASE:

1. To notify users of a problem in the Rev. 5.0 RIIT RPG - See Appendix A.

2. To apply corrections to the Rev. 5.0 release memo - See Appendix B.

1 of 1

9200/920011/9300/930011 Memo #147, Interim Update 1

(3)

APPENDIX A:

A. SOFI'WARE UNIT: Card Cour.t

RIIT - Transient 123

DNCOS 8411/8414 RPG

B. REASON FOR RELEASE:

To notify users of a problem in the Rev. 5.0 RIIT RPG.

c.

PROBLEM:

A processor abnormal condition may occur while compiling Rev. 5.0 RPG programs using ISAM chaining files.

D. SOLUTION:

1. Replace the RPG relocatable element NUTC, found on System Preparation Tape #2, with the relocatable card deck supplied with this release.

2. Relink RIIT using the linker deck located on System Preparation Tape #1 in source element LTDS. Before relinking, change card number RIIT2620 in the linker deck to read as follows:

ENDI EQU *+X ' IOF61+L

3. Delete the loadable RIIT located on System Preparation Tape #1 (loadable elements RIIT through TPl) and replace i t with the newly created RIIT.

9200/920011/9300/930011

Memo *147, Interim Update 1 lof 1 APPENDIX A

(4)

APPENDIX B.

A. AREAS OF CORRECTION TO THE REV. 5.0 RELEASE MEMO:

1. Cover Letter

a. Special Notes - page 2, paragraph 7:

The base address of the loadable Disc Report Program Generator should be X'13S0', not X'lOSO'.

20 Appendix A

a. The following version numbers should be changed on Tape #1:

SUPR V32 should be V34 JBCN V2A should be V2B PHSO VIO should be VII PHSA VS should be VC PHS 2 V13 should be V14 FAST?LDR V3 should be V4 b. Tape #2:

DTFUQ VF should be VIO 3. Appendix C

Page 2, paragraph 3:

SYSI - Supervisor size

<

X'IOBO' should read X'lOSO'.

9200/920011/9300/930011

Memo #147, Interim Update 1 1 of 1 APPENDIX B

Références

Documents relatifs

If the ALTR or SIZE parameters were incorrectly specified, the production of the precautionary diagnostic caused a Supervisor to be generated Which would cause

The basic advantage of this very efficient printing technique is its simplicity and lower cost. Another advantage is the elimination of vertical smear or

She punches a card for each transaction, which includes such information as the policy holder's name, expiration data, producer, coverage and transaction codes,

During a read operation, read data is multiplexed from the slave bus Read Data lines (and the TM02 slave bus receivers), through the TCCM module, to the Data Sync module

Source programs written in the symbolic language are supplemented with precoded sym- bolic routines by the library processor and assembled into machine-language

To load the card Job Control program, read the job control statements, and load problem programs into main storage, a card reading device must be assigned to

compute, write/compute overlap) is speci- fied in the DTFBG definition, the Assembler does not generate the Scheduling routine. In addition, these routines queue

writing a filemark on magnetic tape; reading data from the magnetic tape into the current display group; searching the magnetic tape for identification and tagword numbers, last file