Notch detection in copper tubes immersed in water by leaky compressional guided waves

Sonia DJILIa, Farouk BENMEDDOURb, Emmanuel MOULINb, Jamal ASSAADb, Fouad BOUBENIDERc

aScientific and Technical Center of Research on Welding and Control, BP 64, route de Daly Brahim. Ch´eraga, 16000 Algies. Algeria.

bIEMN, OAE Department, CNRS UMR 8520, University of Valenciennes and Hainaut Cambr´esis, Le Mont Houy 59313 Valenciennes Cedex 9. France.

cLaboratory of physics of materials, University of sciences and technology Houari Boumedienne B.P. 32 El Allia- Bab Ezzouar, 16111 Algiers. Algeria.

Abstract

Tube-orpipe-like structures are used to convey fluids such as gas,oil or wa- ter.These fluids can be transported on land, in sea or in industrial buildings.

Hence, tubes can suffer from mechanical, thermal and chemical stresses. The latter,can severely damage these structures due to the oxidation phenomena.

This damage weakens the structure and reveals cracks and inhomogeneities.

The objective of this work is to detect and characterise damage in tubes im- mersed in water by a non-destructive method. This research work is devoted to the development of an experimental device. This device can detect and locate axy-and nonaxy-symmetric circumferential small notches located on the outer surface of a filled tube and immersed in water using guided waves.

Different sizes of notches are milled into copper tubes with a thin wall are considered. A single transducer is used for emission and reception of leaky guided waves by using the pulse-echo technique. The compressional L(0,2) mode is launched at relatively high frequency using oblique incidence of the

Preprint submitted to NDT & E International April 9, 2015

(2)

transducer in to the fluid. By using the wave leakages, notches of small sizes are detected and located. Inaddition, the sensitivity of the L(0,2) mode to the radial depth and circumferential extent of notches is evaluated. A roughly linear behaviour of the amplitude reflection coefficients is revealed which is in accordance with research works found in the literature.

2

Références

Documents relatifs

On peut quand même reconnaître une trace indirecte de cet ouvrage dans un épisode du chapitre IX : Pécuchet, alors au paroxysme de sa passion mystique, est pris d’une haine

When it is used adnominally, the proximal singular demonstrative pronoun da can also modify the locational demonstrative adverb hini ‘here’ for emphasizing the reference to

EFFECT OF DEFECT ANGULAR-POSITION ON THE WAVE REFLECTION AND TRANSMISSION COEFFICIENTS: NUMERICAL INVESTIGATION BY THE WAVE FINITE ELEMENT

To get the position of damage, we suggest calculating the sparse estimation of the damaged signal on a sliding window over the matrix of reference signals.. The

Résumé - Nous avons obtenu et analysé les spectres Raman de polymères en films minces et de la région interfaciale entre des films de polymères lamellaires, en couplant le

Figure 4 shows the calculated dispersion curves of the lowest order generalized Lamb mode (modified Rayleigh mode) of a steel layer on aluminum substrate for different

(11), the depth of the crack is identified (level III) by comparing the amplitude of the incident wave with the amplitude of the reflected longitudinal wave for a given relation

Figure 3: Experiments: amplitude modification of the guided waves due to the presence of the stringer The stiffened panel has been then impacted with an impact energy