Quantifying Water Ionization by Soft X-rays using a Microfluidic Device

N/A
N/A
Protected

Academic year: 2021

Partager "Quantifying Water Ionization by Soft X-rays using a Microfluidic Device"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: cea-02458793

https://hal-cea.archives-ouvertes.fr/cea-02458793

Submitted on 28 Jan 2020

HAL is a multi-disciplinary open access archive for the deposit and dissemination of sci- entific research documents, whether they are pub- lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Quantifying Water Ionization by Soft X-rays using a

Microfluidic Device

Lucie Huart, Corinne Chevallard, C. Nicolas, Josiane Kaddissy, A. Touati,

Jean-Michel Guigner, Marie-Francoise Politis, P. Mercere, J.-P Renault,

Marie-Anne Herve Du Penhoat

To cite this version:

Lucie Huart, Corinne Chevallard, C. Nicolas, Josiane Kaddissy, A. Touati, et al.. Quantifying Water Ionization by Soft X-rays using a Microfluidic Device. 15th SOLIL Users’ Meeting, Jan 2020, Saint- Aubin, France. �cea-02458793�

(2)

Quantifying Water Ionization by Soft X-rays

using a Microfluidic Device

L. Huart

1;2;3

, C. Chevallard

1

, C. Nicolas

2

, J. Kaddissy

1

,

A. Touati

3

, J-M. Guigner

3

, M.-F. Politis

4

, P. Mercere

2

,

J-P. Renault

1

, M-A. Hervé du Penhoat

3

1NIMBE UMR CEA-CNRS 3685, Saclay, France,

2Synchrotron SOLEIL, Saint Aubin, France,

3IMPMC, Sorbonne Université, UMR CNRS 7590, MNHN, 75005 Paris, France

4LAMBE UMR 8587, Université d'Evry val d'Essonne & Université Paris-Saclay, 91025 Evry, France

ABSTRACT

The description of the biological effects of ionizing radiation requires a good knowledge of the dose deposition processes at both the cellular and molecular scales. However, the specific behavior of subkeV electrons which deposit their energy in nanometric volumes, remains poorly described [1]. Moreover, theoretical calculations have shown that ionizing the K-shell electrons of metal ions in solution can lead to large local production of radical and slow electron species [2]. Irradiating solutions containing metal ions, such as Mg2+, with monochromatic X-rays around their K edges could thus allow to investigate this process.

Liquid water samples were first irradiated in a static cell with monochromatic soft X-rays (0.2-1.4 keV) at the Metrologie beamline (SOLEIL synchrotron, France). Hydroxyl radical quantification was conducted through OH scavenging by benzoate to form the fluorescent hydroxybenzoate [3]. Yields of OH radicals exhibit a minimum around 1.5 keV, in good agreement with the literature [4, 5]. This minimum may be attributed to an increased ionization density in the photo- and Auger electrons tracks. Moreover,OH yields are found relatively independent of the benzoate concentration in the investigated range, which correspond to scavenging times from 170 ns to 170 ps.

Implementation of a new microfluidic cell in the setup has permitted to drastically increase the signal/noise ratio and our detection sensitivity. Therefore, the OH scavenging method was also applied to solutions containing or not Mg ions. By varying the X-ray energy below and above the K-shell of Mg atoms (1317 eV), the OH radicals production was measured in order to probe a threshold effect. Our results will be compared with standard gamma-rays expositions and differences will be highlighted.

REFERENCES

1. 1. D.T. Goodhead and J. Thacker. Int. J. Radiat. Biol. Relat. Stud. Phys. Chem. Med. 31: 541 (1977).

2. V. Stumpf, K. Gokhberg, L. S. Cederbaum, Nature Chemistry 8: 237 (2016).

3. G. Louit, S. Foley, J. Cabillic, H. Coffigny, F. Taran, A. Valleix, J.-P. Renault, S. Pin. Radiat.Phys. Chem. 72: 119 (2005).

4. J. Fulford, P. Bonner, D. T. Goodhead, M.A. Hill, P. O’Neill. J. Phys. Chem. A 103: 11345 (1999).

5. J.A. LaVerne and S.M. Pimblott, J. Phys. Chem. 95: 3196 (1991).

PO-DR-14

Références

Documents relatifs

Lucie Huart, Christophe Nicolas, Marie-Anne Herve Du Penhoat, Jean Philippe Renault, Corinne Chevallard, Jean-Michel Guigner.. To cite

Lucie Huart, Corinne Chevallard, Josiane Kaddissy, Jean-Michel Guigner, M-F Politis, et al... Quan- tifying water ionization by soft X-rays using a

In this study, white beam imaging from a synchrotron X-ray source is used to perform high-speed imaging of an airblast atomizer operated over a range of air flow

Some of the advanced diagnostics used in this project to better understand spray formation include: (1) 2D X-ray radiography and 3D X-ray computed tomography obtained from

quickly as soon as the electric field is applied, and after few minutes it describes the same evolution in time observed in a standard RIC measurement. So, we conclude that the

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des

The studied multilayer rocking-curve is obtained by deconvolution of experimental curve by the spectral distribution of the polarized monochromatic incident beam (see p..

The broken line shows a theoretical maximum efficiency, that is, when wave lengths of a primary x-ray and a fluorescence x-ray are just on the shorter and the longer side of an