• Aucun résultat trouvé

C FIT to be tried

N/A
N/A
Protected

Academic year: 2022

Partager "C FIT to be tried"

Copied!
2
0
0

Texte intégral

(1)

Can J Gastroenterol Vol 26 No 3 March 2012 130

FIT to be tried

Mark R Borgaonkar MD MSc

Department of Medicine, Memorial University, Newfoundland and Labrador

Correspondence: Dr Mark Borgaonkar, Department of Medicine, Memorial University of Newfoundland, 300 Prince Phillip Drive, St John’s, Newfoundland and Labrador A1B 3V6. Telephone 709-777-8072, fax 709-777-7054, e-mail markb@mun.ca

Received and accepted for publication February 15, 2012

C olorectal cancer (CRC) screening has come of age in Canada, with every province now having a screening program either implemented or well underway. These programs are based on the detection of fecal occult blood, with positive results triggering colonoscopy for definitive diagnosis. This approach is supported by high-level evidence demonstrat- ing a mortality benefit for individuals screened in this manner (1-3).

Fecal occult blood testing (FOBT) uses indirect methods to test for the presence of hemoglobin, which can be affected by chemicals, such as vitamin C, or heme from other sources such as red meat. In contrast, fecal immunochemical tests (FIT) use an antibody to detect human glo- bin directly (4). These assays may offer advantages of greater specificity and sensitivity, and improved adherence. Most FITs produce a visual colour change on a strip to indicate a positive result, but some are ana- lyzed using automated systems in a laboratory to provide a quantitative result.

In the current issue of the Canadian Journal of Gastroenterology, Rabeneck et al (5) (pages 131-147) report on the findings of the FIT Guidelines Expert Panel, a group convened to evaluate the latest evi- dence on the use of FITs and to advise ‘ColonCancerCheck,’ the Ontario CRC screening program (5). The group was specifically interested in FIT performance characteristics, usability factors and specimen stability.

Following a comprehensive search of the published literature between 1996 and June 2010, two systematic reviews, three randomized con- trolled trials and four other studies were reviewed in detail. The panel prepared a review of the 13 different FITs currently approved for use in Canada and reviewed websites of pertinent provincial and national health care organizations for relevant evidence.

Three studies compared FIT performance with standard guaiac FOBT (gFOBT). CRC detection was the primary outcome, but some studies also assessed advanced adenoma (AA) detection. Overall, FIT had higher positivity rates (4.8% to 11.2%) than standard gFOBT (2.4% to 7.9%), with similar or slightly lower specificity for CRC detection (90.1% to 95.8% versus 92.4% to 98.1%), resulting in a higher rate of detection of CRC and AA (1.4% FIT versus 0.6% gFOBT). Sensitivity was assessed in only one study, but was significantly higher for FIT for both CRC detection (92.3% versus 30.8% [P<0.01]) and AA detection (33.9% versus 13.6% [P<0.05]). One study compared FIT with Hemoccult SENSA (Beckman Coulter, USA), a more sensitive gFOBT. In that study, FIT positivity was significantly lower than Hemoccult SENSA (3.2% versus 10.1% [P<0.01]), but with significantly higher specificity for CRC (96.9% versus 90.1% [P<0.01]) and AA detection (97.3% ver- sus 90.6% [P<0.01]). The positive predictive value (PPV) for detection of both CRC (5.2% versus 1.5% [P<0.01]) and AA (19.1% versus 8.9%

[P<0.01]) was superior for FIT compared with Hemoccult SENSA.

Studies that evaluated different cut-off levels to define a positive FIT demonstrated increased PPV and specificity at higher cut-off levels (>100 ng/mL) at the expense of a decrease in positivity rate and sensitivity.

All three studies that evaluated patient participation rates noted sig- nificant differences in favour of FIT, with rates ranging from 59.6% to 68%, compared with rates of 46.9% to 55% for FOBT.

The authors were interested in assessing the temperature stability of FITs that used a vial collection method. One study that examined this reported lower positivity rates in warmer months (OR 0.83 [95% CI 0.73 to 0.90] summer compared with winter) and a reduced chance of a positive test for every increase of 1°C average ambient air temperature in the five to 11 days preceding test analysis (OR 0.993 [95% CI 0.989 to 0.996]). A recent Dutch study (6) made the same observations.

However, in that study, return times of up to 10 days did not affect FIT performance, suggesting good specimen stability with respect to time to processing (6).

The findings of this expert panel suggest that FIT is superior to gFOBT for CRC screening. It has higher sensitivity, PPV and CRC detection rates compared with standard gFOBT, and greater specificity and PPV compared with the most sensitive gFOBT, Hemoccult SENSA.

An additional advantage of FIT is superior performance in detecting AAs, enabling not just early detection of CRC but also true prevention by identifying advanced lesions that can be managed endoscopically.

Perhaps of greatest importance, FIT is more acceptable to patients than gFOBT, with participation rates approximately 10% greater than for other FOBTs. This is likely related to a simpler specimen collection pro- cess, no requirement for dietary restrictions and, for most FITs, collection of just one specimen. Indeed, in northern California (USA), a significant improvement in CRC screening participation has been associated with the use of FIT in a comprehensive program, with participation rates ris- ing from 35% in 2004 to 75% in 2011 (4).

Most FIT manufacturers recommend using a cut-off level of 100 ng/mL to define a positive test. However, adjusting that level downward alters the performance characteristics toward greater sensitivity and test posi- tivity at the expense of less specificity and a lower PPV. There are resource implications associated with more positive screening tests (ie, more colonoscopies generated), but ultimately, this leads to more CRC detection. A Dutch cost-effectiveness analysis concluded that 50 ng/mL was the preferred cut-off level in their screening program (7). It is not known whether that result would apply to screening programs operating within Canada.

In conclusion, the FIT Guidelines Expert Panel has completed a comprehensive review of FIT for CRC screening. Their findings are con- sistent with those of other societies and provide a solid evidentiary base to implement FIT for CRC screening in Canada. Attention should be devoted to the temperature stability of FIT kits, a very relevant issue for the extreme seasonal temperature variations in Ontario and other parts of Canada. Further investigation should be conducted to allow for the identification of the optimal cut-off point to define a positive test.

edITorIal

RefeRences

1. Mandel JS, Bond JH, Church TR, et al. Reducing mortality from colorectal cancer by screening for fecal occult blood.

N Engl J Med 1993;328:1365-71.

2. Kronborg O, Fenger C, Olsen J, Jorgensen OD, Sondergaard O.

Randomised study of screening for colorectal cancer with feacal- occult-blood test. Lancet 1996;348:1467-71.

3. Hardcastle JD, Chamberlain JO, Robinson MHE, et al. Randomized controlled trial of faecal-occult-blood screening for colorectal cancer. Lancet 1996;348:1472-77.

4. Levin T. Optimizing colorectal cancer screening by getting FIT right. Gastroenterology 2011;141:1551-5.

5. Rabeneck L, Rumble RB, Thompson F, et al. Fecal immunochemical tests compared with guaiac fecal occult blood tests for population- based colorectal cancer screening. Can J Gastroenterol 2012;28:131-47.

6. van Roon AHC, Hol L, van Vuuren AJ, et al. Are fecal immunochemical test characteristics influenced by sample return time? A population-based colorectal cancer screening trial.

Am J Gastroenterol 2012;107:99-107.

7. Wilschut JA, Hol L, Dekker E, et al. Cost-effectiveness analysis of a quantitative immunochemical test for colorectal cancer screening.

Gastroenterology 2011;141:1648-55.

©2012 Pulsus Group Inc. All rights reserved

(2)

Submit your manuscripts at http://www.hindawi.com

Stem Cells International

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

MEDIATORS

INFLAMMATION

of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Behavioural Neurology

Endocrinology International Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Disease Markers

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

BioMed

Research International

Oncology Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Oxidative Medicine and Cellular Longevity

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

PPAR Research The Scientific World Journal

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Immunology Research

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Journal of

Obesity Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Computational and Mathematical Methods in Medicine

Ophthalmology Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Diabetes Research Journal of

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Research and Treatment

AIDS

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Gastroenterology Research and Practice

Hindawi Publishing Corporation

http://www.hindawi.com Volume 2014

Parkinson’s Disease

Evidence-Based Complementary and Alternative Medicine

Volume 2014 Hindawi Publishing Corporation

http://www.hindawi.com

Références

Documents relatifs

Proportion of zeros identified by the screening procedures as a function of − log 10 (λ t /λ max ) (horizontal axis) and the (log 10 of the) number of iterations (vertical axis):

The optimal interval for screening in patients with a first-degree family history of CRC must balance the risks of unnecessary procedures and the serious implications of

• In 2008, Ontario launched a provincewide colorectal cancer (CRC) screening program, ColonCancerCheck (CCC), offering fecal occult blood testing through family physicians to

• The literature addressing the role of dietary manipulation in improving the specificity of FOBT screening is limited and somewhat mixed, but 4 randomized

The  survey  instrument,  previously  validated  by  col- leagues in the United States, 9,10  was based on a question- naire  developed  for  a 

Dr  Turcotte’s  second  point  concerns  the  anxiety  caused  by  false-positive  screening  results.  He  neglects  to  mention  the  anxiety  and 

It is high time that Canadian doctors rid themselves  of  erroneous  beliefs  about  screening,  particularly  cancer  screening.  First  of  all,  it  is 

In this study, the detection of methylated Wif-1 in stool, urine or serum samples has a higher diagnosis accuracy to detect advanced neoplasia compared to FOBT (0.90 [0.84–0.94]