• Aucun résultat trouvé

Copper for the Prevention of Outbreaks of Health Care–Associated Infections in a Long-term Care Facility for Older Adults

N/A
N/A
Protected

Academic year: 2021

Partager "Copper for the Prevention of Outbreaks of Health Care–Associated Infections in a Long-term Care Facility for Older Adults"

Copied!
6
0
0

Texte intégral

(1)

HAL Id: hal-02135409

https://hal.archives-ouvertes.fr/hal-02135409

Submitted on 3 Jun 2019

HAL is a multi-disciplinary open access archive for the deposit and dissemination of sci- entific research documents, whether they are pub- lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Copper for the Prevention of Outbreaks of Health Care–Associated Infections in a Long-term Care Facility

for Older Adults

Sarah Zerbib, Lydie Vallet, Anaëlle Muggeo, Christophe de Champs, Annick Lefebvre, Damien Jolly, Lukshe Kanagaratnam

To cite this version:

Sarah Zerbib, Lydie Vallet, Anaëlle Muggeo, Christophe de Champs, Annick Lefebvre, et al.. Cop- per for the Prevention of Outbreaks of Health Care–Associated Infections in a Long-term Care Facility for Older Adults. Journal of the American Medical Directors Association, Elsevier, 2019,

�10.1016/j.jamda.2019.02.003�. �hal-02135409�

(2)

Original Study

Copper for the Prevention of Outbreaks of Health Care e Associated Infections in a Long-term Care Facility for Elders

Sarah Zerbib

a,

*, Lydie Vallet

b

, Anaëlle Muggeo

Q 3 c

, Christophe de Champs

b,c

,

Annick Lefebvre

Q 2 b

, Damien Jolly

a

, Lukshe Kanagaratnam

a

Q 1

aUnité d’Aide Méthodologique, CHU de Reims, Reims, France

bEquipe Opérationnelle Hygiène, CHU de Reims, Reims, France

cLaboratoire de Bactériologie, CHU de Reims, Reims, France

Keywords:

Cross infection copper disease outbreaks

a b s t r a c t

Objective:We aimed to study the efficacy of copper as an antimicrobial agent by comparing incidence rates during outbreaks in areas equipped vs not equipped with copper surfaces in a long-term facility for dependent elderly persons (nursing home).

Design:Prospective observational pilot study in a nursing home.

Setting and participant:All persons resident in the nursing home belonging to a University Hospital, from February 1, 2015, to June 30, 2016, were included.

Methods:Incidence rates for health careerelated infections during outbreaks occurring during the study period were compared between the wing that was equipped and the wing that was not equipped with copper surfaces. Results are expressed as relative risks (RRs) and 95% confidence intervals (95% CIs).

Results:During the study period, 556 residents were included; average age was 85.4 9.2 years, 76%

were women. Four outbreaks occurred during the study period: 1 influenza, 1 keratoconjunctivitis, and 2 gastroenteritis outbreaks. The risk of hand-transmitted health careeassociated infection was signifi- cantly lower in the area equipped with copper surfaces (RR 0.3, 95% CI 0.1-0.5).

Conclusion: and implication: In our study, copper was shown to reduce the incidence of hand- transmitted health careeassociated infections and could represent a relatively simple measure to help prevent HAIs in nursing homes.

2019 Published by Elsevier Inc. on behalf of AMDAeThe Society for Post-Acute and Long-Term Care Medicine.

The antimicrobial properties of copper have been used for thou- sands of years and by many human civilizations, for a variety of uses, from the sterilization of drinking water to the topical treatment of leg ulcers.

1

In more recent times, copper has been used to control nosocomial infections.

2

It has been suggested that copper should be used to coat contact surfaces.

3e20

Indeed, solid surfaces can act as a reservoir for pathogens, thereby participating in the transmission of infections by hand contact. In vitro, copper surfaces show effectiveness against a large variety of pathogens (ie, bacteria, virus, and fungi).

20

Few studies have investigated the ef

cacy of copper as a contact surface in reducing health care

e

associated infections (HAIs) from a

clinical point of view, and fewer were interventional studies.

6,8,9,11,12

A randomized, multicenter study in the intensive care unit by Salgado et al

7

showed that patients cared for in areas with copper alloy sur- faces had a signi

cantly lower risk of nosocomial infection. A quasi- experimental study by Von Dessauer et al

8

showed a numerical, although not statistically signi

cant, reduction in HAIs in patients assigned to rooms with copper surfaces.

Therefore, the role of copper in the prevention of HAIs remains to be clari

ed, with con

icting results existing in the literature.

Furthermore, existing studies were mainly performed in intensive care units in the hospital setting. To our knowledge, no study to date was performed in the setting of a long-term care facility for dependent elderly persons (nursing home). Indeed, elderly populations (older than 65 years) are at risk for susceptibility to HAIs, with a 15-fold increase in infections in patients hospitalized for more than 30 days, compared to those whose hospital stay lasts only 2 to 7 days.

21

Against this background, we aimed to investigate the ef

cacy of copper as an antimicrobial agent by comparing incidence rates of

The authors declare no conflicts of interest.

* Address correspondence to Sarah Zerbib, Reims University Hospitals, Robert Debré Hospital, Department of Research and Innovation, Rue du Général Koenig - F51092 Reims, France.

E-mail address:szerbib@chu-reims.fr(S. Zerbib).

https://doi.org/10.1016/j.jamda.2019.02.003

1525-8610/2019 Published by Elsevier Inc. on behalf of AMDA The Society for Post-Acute and Long-Term Care Medicine.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110

JAMDA

j o u r n a l h o m e p a g e :w w w . j a m d a . c o m

(3)

infection during outbreaks between an area equipped and an area not equipped with copper surfaces in a nursing home setting.

Methods

We performed a prospective, longitudinal, observational pilot study in a nursing home operating under the auspices of a University Hospital.

Study Population

All patients residing in the nursing home during the period from February 1, 2015, to June 30, 2016, were included in the study.

Study Intervention

The nursing home had a capacity of 362 beds in total. The buildings of the nursing home comprise 2 distinct wings (AB wing and CD wing), each with 3

oors. Units A and B occupy the right wing, and Units C and D occupy the left wing. On each

oor, there are areas that are common to both wings, such as dining rooms, game rooms and outdoor areas (patio, depending on the

oor) (Supplementary

Material).

The CD wing was randomly chosen to be equipped with antimi- crobial copper surfaces. The premises were equipped from April 2014 onwards with 438 door handles, 322 m of handrails, and 10 grab-bars in copper alloy (containing from 80% to 90% copper).

Data Recorded

During the study period, the outbreaks that occurred were recor- ded by noting the start date of symptoms for each individual. Out- breaks were de

ned as the onset of grouped cases with similar symptoms, that is, the occurrence of at least 5 cases in 4 days.

22

All diagnoses were made by the physician in the nursing home.

All biological samples were analyzed in the Virology and Bacteri- ology Laboratory of a University Hospital for identi

cation of the causal pathogen.

For each patient, we also recorded, sex, age, length of stay before inclusion in the study, occurrence of infection (yes/no) and, if yes, the type of infection.

Statistical Analysis

Incidence rates of HAIs with 95% con

dence intervals (CIs) were calculated in each wing, for each outbreak individually, and overall for all outbreaks observed during the study period, and also grouping only outbreaks caused by hand-transmitted pathogens. When the causal germ was not identi

ed, we recorded the average incubation period for the germ most frequently encountered in that type of outbreak.

23,24

For the calculation of incidence rates, the numerator was the number of new cases for each outbreak and the denominator was the theoretical duration of exposure to the infection expressed in person- days. The start of the exposure period for noninfected residents was the date of the

rst case minus the duration of incubation of the causal

germ. The end of the exposure period was the date of the last case plus the duration of incubation of the causal germ.

23e25

For cases, the duration of exposure was from the date of the

rst case minus the duration of incubation of the causal germ up to the date of onset of symptoms.

The relative risk was calculated as the ratio of the incidence of outbreaks in the wing equipped with copper surfaces to the incidence of outbreaks in the wing not thus equipped. The 95% con

dence in- tervals of the relative risk were calculated according to Katz

s method.

26

When the incidence rate in a wing was equal to zero (ie, no cases), we estimated the relative risk by calculating the incidence rate with a single case as the numerator.

Quantitative variables were described as mean standard devia- tion, and qualitative variables as number (percentage). Qualitative variables were compared using the chi-square test, with Yates correction when necessary according to the conditions of application.

A

P

value

<

.05 was considered statistically signi

cant. All analyses were performed with SAS version 9.4 (SAS Institute, Inc, Cary, NC).

The evaluation presented here was conducted independently by members of the Research Center of a University Hospital, after having warned a priori the company of the realization of this project.

Results

During the study period, 556 residents were included in the study;

289 in the AB wing, 72% of whom were women, and 267 in the CD wing, among whom 79% were women. The mean age of the AB wing was 85.4 9.6 years vs 85.4 8.8 in the CD wing. The average length of stay prior to inclusion was 2.8 3.2 years in the AB wing vs 3.1 5.4 in the CD wing. For all these characteristics, the differences between the 2 wings appeared nonsigni

cant.

Overall, during the study period, there were 4 documented out- breaks:

u in February 2015, keratoconjunctivitis in November 2015, gastroenteritis in March 2016, and gastroenteritis again in June 2016 (characteristics of the outbreaks detailed in

Table 1).

The pathogens identi

ed were In

uenza A virus for outbreak 1, and Norovirus for outbreak 4. No germ could be positively identi

ed for outbreaks 2 (keratoconjunctivitis) and 3 (gastroenteritis). It was thus assumed that the responsible pathogens were those most frequently encountered in these infections, namely, Adenovirus and Norovirus, respectively.

For outbreak 1 (

u), the risk of infection was signi

cantly increased among patients residing in the wing equipped with copper surfaces (Table 2). For outbreaks 2 and 3 (keratoconjunctivitis and gastroen- teritis), the risk of infection was signi

cantly lower in the wing equipped with copper surfaces (Table 2).

Finally, for outbreak 4 (gastroenteritis), there was no signi

cant difference in the risk of infection between the wing equipped vs the wing not equipped with copper surfaces (Table 2).

Considering all 4 outbreaks together, there was no signi

cant dif- ference in the risk of infection between wings. Conversely, when considering only the 3 outbreaks caused by hand-transmitted path- ogens, there was a signi

cant decrease in the risk of infection in the wing equipped with copper surfaces (relative risk 0.3, 95% con

dence interval 0.1-0.5) (Table 2).

Table 1

Description of Outbreaks Occurring During the Study Period

Outbreak Disease Causal Pathogen Number of Cases Number of Samples Number of Samples Positive Duration, d

1 Flu Influenza A 18 11 4 6

2 Keratoconjunctivitis Non identified 19 6 0 12

3 Gastroenteritis Non identified 10 2 0 3

4 Gastroenteritis Norovirus 26 4 1 8

S. Zerbib et al. / JAMDA xxx (2019) 1e4 2

111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175

176

177

178

179

180

181

182

183

184

185

186

187

188

189

190

191

192

193

194

195

196

197

198

199

200

201

202

203

204

205

206

207

208

209

210

211

212

213

214

215

216

217

218

219

220

221

222

223

224

225

226

227

228

229

230

231

232

233

234

235

236

237

238

239

240

(4)

Discussion

Our study shows a protective effect of copper surfaces against the risk of HAIs, but only (and quite logically) those caused by hand- transmitted pathogens (gastroenteritis and keratoconjunctivitis).

Regarding the

u outbreak, the results not only show that there is no protective effect of copper surfaces but actually suggest the opposite. Although copper has been shown to be ef

cacious against the In

uenza A virus in vitro,

27

transmission of the

u is predomi- nantly airborne.

28

It is therefore unsurprising that copper surfaces should afford no protection, especially given that the point source was the wing that was equipped with copper surfaces.

As for the second (keratoconjunctivitis) and third outbreaks (gastroenteritis), the risk of infection was signi

cantly lower in the wing equipped with the copper surfaces, with all infections occurring exclusively in the other wing. Indeed, it has previously been reported that biocidal surfaces made of, or containing, copper can reduce the microbiological burden, including ef

cacy against Adenovirus

20,27,29

and Norovirus.

30

The last outbreak (gastroenteritis), con

rmed by to be caused by Norovirus, occurred simultaneously in both wings, with 15 cases in the wing nonequipped with copper surfaces vs 11 in the equipped wing, yielding a non

e

statistically signi

cant difference.

When we analyzed all outbreaks together, there was no signi

cant difference between copper-equipped and nonequipped wings in terms of risk of infection, which is likely driven by the inclusion of the airborne infection (

u), where the majority of cases occurred in the copper-equipped wing. Conversely, when the risk of infection was analyzed only for outbreaks caused by hand-transmitted pathogens, there was a clear and signi

cant reduction in risk in the copper- equipped wing, con

rming the protective effect of copper surfaces against hand-transmitted infections.

The results of our study are coherent with the largest interven- tional study to date to investigate the effectiveness of copper- impregnated composite hard surfaces and linens in an acute care hospital to reduce HAIs. In that study, Sifri et al

9

assessed the devel- opment of HAIs due to multidrug-resistant organisms, and in partic- ular

Clostridium difficile, in acute care units of a community hospital.

No change was observed in the rate of infections in the nonequipped wing, whereas there was a signi

cant, 78% reduction in the rate of HAIs in the copper-equipped wing.

Salgado et al reported similar

ndings,

6

but in a multicenter study of 3 intensive care units in the United States, the authors reported a signi

cant reduction in the rate of HAIs, from 8.1% in nonequipped rooms to 3.4% in equipped rooms (P

<

.02).

In our study, the geographical structure of the nursing home, with 2 distinct wings that shared certain common areas, presented the advantage of being able to investigate the spread of outbreaks in each wing separately. In addition, to our knowledge, this is the only study to have been performed in a nursing home, which offers an opportunity

to study other pathogens than those commonly observed in inter- ventional studies performed in intensive care units. Indeed, in hospital-based studies, the majority of infections were bacterial, particularly methicillin-resistant

Staphylococcus aureus, vancomycin-

resistant

Enterococcus

or

Clostridium difficile.6,8,9

In our study, the outbreaks were of viral origin, and copper has also been shown to be ef

cacious against viruses.

20

A further strongpoint of our study is that it directly assessed HAIs, and not simply bacterial samples for culture. Indeed, the majority of studies on the utility of copper contact surfaces in the health care environment used a biological endpoint that measured bioburden as assessed by colony-forming units, without taking clinical criteria into account.

4,5,7,10,13e19,29

Nonetheless, our study has some limitations. We do not have data relating to comorbidities or nutritional status in the residents of the nursing home at the time of the study, which may have been potential risk factors favoring the onset of infection in these subjects.

31

Consequently, this may have introduced bias in the analysis of the rate of infection. We also lack data in this study about potential con- founders due to the health care personnel, such as the number of staff assigned to each wing, and the frequency with which the staff could switch wings, or whether the staff scrupulously respected the stan- dardized precautions and hygiene measures to limit the spread of infection. In case of outbreaks, hygiene recommendations, informa- tion to visitors and cleaning protocols are identical for both wings.

A further limitation of this study is the absence of microbiological con

rmation of the causal agent for all outbreaks. Indeed, in practice, patients did not systematically undergo sampling for identi

cation of the germ responsible for infection, and only a low number of the samples that were taken actually returned a positive result.

Finally, another potential limitation for results extension could be the cost of copper equipment. To get an idea, the price of a copper handrail is

V

200/m vs

V

40/m for a standard stainless steel handrail and

V

75 for copper door handles vs

V

20 for a standard stainless steel door handle.

Conclusion and Implication

In conclusion, our study shows that copper surfaces help to reduce the incidence rate of infection during outbreaks caused by hand- transmitted pathogens. The installation of antimicrobial copper or copper-containing surfaces (such as door handles, support bars, and handrails) could represent a relatively simple measure to help to prevent HAIs in nursing homes.

References

1. O’Gorman J, Humphreys H. Application of copper to prevent and control infec- tion. Where are we now? J Hosp Infect 2012;81:217e223.

Table 2

Incidence Rates and Relative Risks for Infection in the Wing Equipped (CD Wing) vs the Wing Nonequipped (AB Wing) With Copper Surfaces

No. Outbreak AB Wing (Not Equipped) CD Wing (Equipped) RR (95% CI) P

Cases IR*(95% CI) Cases IR*(95% CI)

1 Influenza A 1 0.1 (0-0.2) 17 1.1 (0.6-1.7) 21.0 (2.8-158.2) <.001

2 Adenovirus 19 0.3 (0.2-0.5) 0 e 0.1 (0.01-0.5)y <.001

3 Norovirus 10 1.0 (0.4-1.7) 0 e 0.1 (0.02-0.9)y .03

4 Norovirus 15 0.7 (0.4-1.1) 11 0.6 (0.3-1.0) 0.9 (0.4-1.9) .88

1, 2, 3, 4 All outbreaks 45 0.04 (0.03-0.06) 28 0.03 (0.02-0.04) 0.7 (0.4-1.1) .14

2, 3, 4 Hand-transmitted only 44 0.09 (0.06-0.12) 11 0.02 (0.01-0.04) 0.3 (0.1-0.5) <.001

IR, incidence rate; CI, confidence interval; RR, relative risk.

*Incidence rates are expressed per 100 person-days.

yThe RR was calculated on the basis of a single case in the wing nonequipped with copper surfaces.

241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305

306

307

308

309

310

311

312

313

314

315

316

317

318

319

320

321

322

323

324

325

326

327

328

329

330

331

332

333

334

335

336

337

338

339

340

341

342

343

344

345

346

347

348

349

350

351

352

353

354

355

356

357

358

359

360

361

362

363

364

365

366

367

368

369

370

(5)

2. Grass G, Rensing C, Solioz M. Metallic copper as an antimicrobial surface. Appl Environ Microbiol 2011;77:1541e1547.

3. Weaver L, Michels HT, Keevil CW. Survival ofClostridium difficileon copper and steel: Futuristic options for hospital hygiene. J Hosp Infect 2008;68:

145e151.

4. Souli M, Antoniadou A, Katsarolis I, et al. Reduction of environmental contam- ination with multidrug-resistant bacteria by copper-alloy coating of surfaces in a highly endemic setting. Infect Control Hosp Epidemiol 2017;38:765e771.

5. Hinsa-Leasure SM, Nartey Q, Vaverka J, et al. Copper alloy surfaces sustain ter- minal cleaning levels in a rural hospital. Am J Infect Control 2016;44:e195ee203.

6. Salgado CD, Sepkowitz KA, John JF, et al. Copper surfaces reduce the rate of healthcare-acquired infections in the intensive care unit. Infect Control Hosp Epidemiol 2013;34:479e486.

7. Schmidt MG, von Dessauer B, Benavente C, et al. Copper surfaces are associated with significantly lower concentrations of bacteria on selected surfaces within a pediatric intensive care unit. Am J Infect Control 2016;44:203e209.

8. Von Dessauer B, Navarrete MS, Benadof D, et al. Potential effectiveness of copper surfaces in reducing health care-associated infection rates in a pediatric inten- sive and intermediate care unit: A nonrandomized controlled trial. Am J Infect Control 2016;44:e133ee139.

9. Sifri CD, Burke GH, Enfield KB. Reduced health care-associated infections in an acute care community hospital using a combination of self-disinfecting copper- impregnated composite hard surfaces and linens. Am J Infect Control 2016;44:

1565e1571.

10. Schmidt MG, Tuuri RE, Dharsee A, et al. Antimicrobial copper alloys decreased bacteria on stethoscope surfaces. Am J Infect Control 2017;45:642e647.

11. Lazary A, Weinberg I, Vatine J-J, et al. Reduction of healthcare-associated in- fections in a long-term care brain injury ward by replacing regular linens with biocidal copper oxide impregnated linens. Int J Infect Dis 2014;24:23e29.

12. Marcus E-L, Yosef H, Borkow G, et al. Reduction of health careeassociated infection indicators by copper oxideeimpregnated textiles: Crossover, double-blind controlled study in chronic ventilator-dependent patients. Am J Infect Control 2017;45:401e403.

13. Schmidt MG, Attaway HH Iii, Fairey SE, et al. Copper continuously limits the concentration of bacteria resident on bed rails within the intensive care unit.

Infect Control Hosp Epidemiol 2013;34:530e533.

14. Schmidt MG, Attaway HH, Sharpe PA, et al. Sustained reduction of microbial burden on common hospital surfaces through introduction of copper. J Clin Microbiol 2012;50:2217e2223.

15. Karpanen TJ, Casey AL, Lambert PA, et al. The antimicrobial efficacy of copper alloy furnishing in the clinical environment: A crossover study. Infect Control Hosp Epidemiol 2012;33:3e9.

16. Casey AL, Karpanen TJ, Adams D, et al. A comparative study to evaluate surface microbial contamination associated with copper-containing and stainless steel pens used by nurses in the critical care unit. Am J Infect Control 2011;39:

e52ee54.

17. Casey AL, Adams D, Karpanen TJ, et al. Role of copper in reducing hospital environment contamination. J Hosp Infect 2010;74:72e77.

18. Mikolay A, Huggett S, Tikana L, et al. Survival of bacteria on metallic copper surfaces in a hospital trial. Appl Microbiol Biotechnol 2010;87:1875e1879.

19. Marais F, Mehtar S, Chalkley L. Antimicrobial efficacy of copper touch surfaces in reducing environmental bioburden in a South African community healthcare facility. J Hosp Infect 2010;74:80e82.

20. Borkow G, Monk A. Fighting nosocomial infections with biocidal non-intrusive hard and soft surfaces. World J Clin Infect Dis 2012;2:77e90.

21. INSERM. Infections nosocomiales. Available at: https://www.inserm.fr/

thematiques/immunologie-inflammation-infectiologie-et-microbiologie/dossie rs-d-information/infections-nosocomiales. Accessed November 6, 2017.

22. ARS (Agence Régionale de Santé). Surveiller et gérer les épidémies dans les établissements médico-sociaux. Available at: http://www.grand-est.ars.

sante.fr/surveiller-et-gerer-les-epidemies-dans-les-etablissements-medico-soc iaux. Accessed October 18, 2018.

23. ANSES (Agence Nationale de Sécurité Sanitaire de l’alimentation, de l’envir- onnement et du travail). Norovirus. Available at: https://www.anses.fr/fr/

system/files/MIC2011sa0036Fi. Accessed October 25, 2017.

24. Renard G. Kératoconjonctivites à adénovirus. J Fr Ophtalmol 2010;33:586e592.

25. OMS (Organisation Mondiale de la Santé). Grippe (saisonnière). Available at:

http://www.who.int/mediacentre/factsheets/fs211/fr/. Accessed November 6, 2017.

26. NCSS. Confidence intervals for two proportions. Available at:https://www.ncss.

com/wpcontent/themes/ncss/pdf/Procedures/PASS/Confidence_Intervals_for_

Two_Proportions.pdf. Accessed October 28, 2018.

27. Borkow G, Sidwell RW, Smee DF, et al. Neutralizing viruses in suspensions by copper oxide-basedfilters. Antimicrob Agents Chemother 2007;51:2605e2607.

28. Institut Pasteur. Grippe. Available at:https://www.pasteur.fr/fr/centre-medical/

fiches-maladies/grippe. Accessed November 6, 2017.

29. Lewis A. The hygienic benefits of antimicrobial copper alloy surfaces in healthcare settings. Available at:https://cuverro.com/sites/default/files/oem_

files/ip010lewis-2009.pdf. Accessed October 28, 2018.

30. Warnes SL, Keevil CW. Inactivation of norovirus on dry copper alloy surfaces.

PLoS One 2013;8:e75017.

31. Laurent M, Bastuji-Garin S, Plonquet A, et al. Interrelations of immunological parameters, nutrition, and healthcare-associated infections: Prospective study in elderly in-patients. Clin Nutr Edinb Scotl 2015;34:79e85.

S. Zerbib et al. / JAMDA xxx (2019) 1e4 4

371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435

436

437

438

439

440

441

442

443

444

445

446

447

448

449

450

451

452

453

454

455

456

457

458

459

460

461

462

463

464

465

466

467

468

469

470

471

472

473

474

475

476

477

478

479

480

481

482

483

484

485

486

487

488

489

490

491

492

493

494

495

496

497

498

499

500

(6)

Appendix

Supplementary Material.Plan of Nursing Home.

501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565

566

567

568

569

570

571

572

573

574

575

576

577

578

579

580

581

582

583

584

585

586

587

588

589

590

591

592

593

594

595

596

597

598

599

600

601

602

603

604

605

606

607

608

609

610

611

612

613

614

615

616

617

618

619

620

621

622

623

624

625

626

627

628

629

630

Références

Documents relatifs

This adsorption is divided into two zones: a diffusion region and a kinetic area controlled by the reaction. The thermodynamic parameters show that the sorption is spontaneous

never been fully tested, since in order to deter- mine the activation parameters of a thermally acti- vated-process, it is necessary to create conditions in which

The appearance of a bright or dark dislocation contrast in the cathodoluminescence pictures is related for different diffusion conditions: I) to the enrichment of copper acceptors

Blood samples were collected each month and different serum markers for WD (namely ceruloplasmin oxidase activity, exchangeable copper (CuEXC), total serum copper and REC) and

Health care facilities must execute infection prevention and control policies supported by institutional management.. An overall approach to an infection prevention and

The transfer of domiciliary care services from the AWBZ to the WMO, and more generally the upgrading of the role of local government in LTC by the additional transfer

Unit four discussed elements of the RAI-MDS 2.0 admission assessment, including what it is used for and when it is completed. It also explained how CAPS and the CAPS summary are

The resource manual developed for LPNs defines high risk older adults, changes in the aging feet and toenails, describes common skin, nail, and joint pathologies seen in the