• Aucun résultat trouvé

Imaging and analysis of an apple pest behaviour:MRI and X-ray microtomography comparison

N/A
N/A
Protected

Academic year: 2021

Partager "Imaging and analysis of an apple pest behaviour:MRI and X-ray microtomography comparison"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: hal-00964167

https://hal.archives-ouvertes.fr/hal-00964167

Submitted on 6 Jun 2020

HAL is a multi-disciplinary open access

archive for the deposit and dissemination of

sci-entific research documents, whether they are

pub-lished or not. The documents may come from

teaching and research institutions in France or

abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est

destinée au dépôt et à la diffusion de documents

scientifiques de niveau recherche, publiés ou non,

émanant des établissements d’enseignement et de

recherche français ou étrangers, des laboratoires

publics ou privés.

Imaging and analysis of an apple pest behaviour:MRI

and X-ray microtomography comparison

Amidou Traore, David Georges Biron, Fanette Chevallier, Boris Adam, M.

Saudreau, Benoit Sauphanor, Christine Girousse, Eric Badel

To cite this version:

Amidou Traore, David Georges Biron, Fanette Chevallier, Boris Adam, M. Saudreau, et al.. Imaging

and analysis of an apple pest behaviour:MRI and X-ray microtomography comparison. MR In Food,

Sep 2010, Clermont-Ferrand, France. 2 p. �hal-00964167�

(2)

IMAGING AND ANALYSIS OF AN APPLE PEST BEHAVIOUR: MRI AND X-RAY

MICROTOMOGRAPHY COMPARISON

Amidou Traore

1

, David G. Biron

2,3

, Fanette Chevalier

2,3

, Boris Adam

2,3

, Marc Saudreau

2,3

,

Benoit Sauphanor

4

, Christine Girousse

5

, Eric Badel

2,3

Conclusions and prospect: MRI is very efficient for high water content products. Microtomography is very efficient for biphasic materials if densities are quite different (e. g., solid-air porous media). MRI is the preferred tool for quantifying the amount of water and its state in the sample while the CT is used to differentiate solid phases. X-ray technologies provide better spatial resolution than MRI. Thus, MRI and X-ray microtomographic technologies are complementary tools. Nevertheless, in case of the study of the 3D tunnel made by the codling moth in the apple, both tools give relevant results because:

-high spatial resolution was not required

-the main issue was to separate the solid phase (apple= porous solid media filled with water) from the air phase (tunnel). Few points of major difference:

- X-ray microtomography can provide very high spatial resolution (up to 1 µm) and does not require more time for isotropic volume. The complete isotropic volumes make easier 3D distance measurements for morphology characterizations.

-Time: for the same spatial resolution and same Signal / Noise ratio, the acquisition time would be around 1 to 2 min with X-ray microtomography. - Safety point: X-ray microtomography generates ionization (safety issue for living beings: the caterpillar died few days after X-ray experiments) - X-ray microtomography is not efficient to separate water from other components if they show similar densities

- X-ray microtomography is very efficient for multiphase materials with contrasted absorption properties since differences in magnetic susceptibilities at the air–parenchyma interface damage the signal and lead to the overestimation of tunnel size. Specific sequences could be developed for such application. Both tools provide a good description of the caterpillar tunnel. Thus they can be used to characterize the evolution of the tunnel diameter and to observe the behavior of the mining pest. Nevertheless, MRI is safe for the caterpillar since X-ray microtomography could be much faster for dynamic observations.

1 INRA, Centre Clermont-Ferrand/Theix, UR370 QuaPA/NMR plateforme, F-63122 Saint Genès Champanelle 2 INRA, UMR 547 PIAF, F-63000 Clermont-Ferrand, France

3 University Blaise Pascal, UMR 547 PIAF, F-63000 Clermont-Ferrand, France 4 INRA, UR 1115 PSH, F-84914 Avignon, France

5 INRA, UMR 1095 GDEC, F-63000 Clermont-Ferrand, France

Purposis:

Material

et methods

:

Results:

D I E T A G R I C U L T U R E E N V I R O N M E N T

As part of the research work dealing with the potential effect of pest behaviors on apple, MRI and X-ray imaging were compared in their ability to extract 3D tunnel made by the codling moth, Cydia pomonella (L) (Lepidoptera: Tortricidae), especially when they are exposed to the biological insecticide: the codling moth granulovirus CpGV. The target stage is the first caterpillar stadium when the C. pomonella caterpillar feeds on apple by making a mine that characterizes the codling moth’s behavior.

MRI

MRI follow up (3 weeks and twice a week) was conducted on a Bruker Biospec 47/40 spectrometer with BGA 26 gradients unit and 20 cm-diameter Birdcage RF coil

Imaging protocol : RARE T1 pulse sequence (TR/TE =1200/12

ms), 4 segments; Up to 96 1-mm thick slice images (to cover the whole apple in the axial, sagittal and coronal planes) were acquired for each session with a FOV of 9.6 cm and 256x256 matrix size

Image processing: A home-made image processing software

(PiafBto3D*) was used to reconstruct 3D volume from the set of 2D images and to extract tunnels.

Contact MRI: amidou.traore@clermont.inra.fr * B. Adam2,3

X-Ray microtomography

Equipment: Phoenix X-ray Nanotom© microtomograph* Imaging: 1620 frames (angle step = 0.22°). Voltage= 60 kV,

Intensity = 400 mA, no X-ray filter

Acquisition time: 750ms / frame

Reconstructed volume: 1100x1170x1100 voxels Format: 16 bits dynamic

Image processing : ImageJ was used to extract the tunnel

according to the x-ray absorption contrast and to visualize the air phase.

Contact X-ray microtomography: eric.badel@clermont.inra.fr

* The authors thank Mr Hemberger (Phoenix X-ray-Limonest-France) for the use of their Nanotom© device

3D mapping of the tunnel diameter

X-ray source

2D detector

3D reconstruction

Signal / Noise measurements seed: S / N = 14 apple: S / N = 13 noise evaluation 0 0.25 0.50 0.75 1.00 1.25 0 5 10 15 20 25

Distance from the apple's skin (mm)

Dia m eter of t h e tu nne l (m m )

3D visualization of the air phase

Evolution of the tunnel diameter of the caterpillar

Entry point (skin) Arriving point (seed)

Obstruction of the entrance (dejections ?) Signal / Noise measurements

seed: S / N = 22 apple: S / N = 8 noise evaluation

Acquisition Time: 20 min 15’ Spatial resolution: 60x60x60 µm3/voxel

Acquisition Time: 4 hours 20 min Spatial resolution: 375x375x1000µm3/voxel

X-ray microtomography

MRI

3D reconstruction via PiafBto3D

Références

Documents relatifs

As hydraulic fractures migrate parallel to the main compressive stress, they represent a measure of the local main stress direction in the Earth’s crust (Talebi and Cornet,

The axial distribution of main matrix cracks and fiber breaks (as defined in section 1.3) are presented in figure 7 from radiograph observation performed at 92 N of the entire

As we will see, Ife demonstrates a harmony policy that is thus for- mally identical to Finnish: non-contrastive vowels are fully transparent in medial positions, but when

A key question that remains unclear in the ICCAT Commission management recommendation is: which species are primarily targeted by the FAD-moratorium. While it seems implicitly

(A) Combined segmentation for the 140.. Cumulative granulometry of the original particles used in the cold-sprayed coating and of the segmented image. Results are given for

Synchrotron X-ray micro- tomography and lattice Boltzmann simulations of gas flow through volcanic pumices... Large three dimensional images at high spatial resolution were

(a) Total organic carbon content (wt % TOC), (b) total alkenone content ( mg per gram of sediment), (c) total alkenone content relative to TOC ( mg per gram of TOC), (d)

competition is always assumed.8 It has been accordingly assumed in the Italian enquiry that where some additional labour would have to be engaged for a peak