• Aucun résultat trouvé

Dynamic Response of a Stand Alone AC Side Wind Energy Conversion System

N/A
N/A
Protected

Academic year: 2021

Partager "Dynamic Response of a Stand Alone AC Side Wind Energy Conversion System "

Copied!
1
0
0

Texte intégral

(1)

The First International Conference on Power Electronics and their Applications ICPEA 2013, November 17-18, Djelfa 2013

Dynamic Response of a Stand Alone AC Side Wind Energy Conversion System

F. BRIHMAT, S. MEKHTOUB

A bstract

This Paper consists on the study of one part of wind energy system conversion, its AC side.

Renewable resources are in constant fluctuation. This situation could put in peril the energizing efficiency towards a given demand requirement. Therefore, in order to maximize the efficiency of the renewable energy system, it is necessary to track the maximum power point of the input source, a study established under MATLAB/Simulink platform. For the wind system, the maximizing is assured while considering the optimal power curve as load characteristic, with the knowledge of the turbine characteristic Cp λ . Then, this work elaborates the analysis and simulation of a low speed Permanent Magnet Synchronous Generator (PMSG) driven by a vertical wind turbine through a Pulse-Width Modulation (PWM) voltage inverter, independently of the DC components of the wind system conversion, using MATLAB computer simulation.

Références

Documents relatifs

Maximum Power Point Tracking (MPPT) strategy [5]. Then, an optimal electromagnetic torque, which ensures the rotor speed convergence to ω ref is computed using the following

This paper presents a study for optimal operation of a PMSM motor for wind turbine generator pumping system under its non linear and complicate model with

Abstract — In this work we presents comparative study of a variable speed wind energy conversion system (WECS) based on the doubly fed induction generator (DFIG) driven by two

The AC study concerned the analysis and simulation of a low speed Permanent Magnet Synchronous Generator (PMSG) driven by a vertical wind turbine through a Pulse-Width Modulation

The AC study concerned the analysis and simulation of a low speed Permanent Magnet Synchronous Generator (PMSG) driven by a vertical wind turbine through

For the wind system, the maximizing is assured while considering the optimal power curve as load characteristic, with the knowledge of the turbine characteristic C_p (?).Then, this

‘MPPT for PM wind generator using gradient approximation’, Energy Conversion and Management 50 (1), pp. ‘Maximum power point tracker of wind energy conversion system’,

Modelling and Simulation of a Doubly Fed Induction Generator for isolated Grid(l) Micro-Hydro Power station(2) in Variable Speed Turbine for equatorial medium RAMUZ Denis